An Experimental Investigation of Essential Hand Tremor Suppression via a Soft Exoskeletal Glove
Open accessAbstract
In this article, a soft exoskeletal glove is proposed for investigating the potential of utilizing Pneumatic Artificial Muscles (PAMs) for suppressing hand tremor of Essential Tremor (ET) patients. The glove setup is first presented from a conceptual point, which is focused on the dual investigation of applying local kinesthetic forces exerted via PAMs on the user's finger and on the metacarpal region. An experimental protocol is being derived incorporating a force controller adjusted for both investigated cases, while the efficiency of the proposed setup is extensively evaluated under various motion scenarios performed by an ET-diagnosed volunteer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By using this force as the set point for a closed-loop controller, both prototypes obtained a maximal reduction of 75% in amplitude and 70% in frequency (61).”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“Using the prototypes under open-loop control, the authors obtained the force that provided the maximal decrease in tremor amplitude (89%) and frequency (70%) for one ET patient.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“Except for one of the reviewed works (61), the rest of them only presented experimental validations with healthy subjects or artificial platforms.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“As a result, there is yet a lack of proper validation of these actuators as a feasible solution for tremor management. In fact, only the soft exoskeletal glove presented by Skaramagkas et al. (61) presented a validation involving one actual ET patient.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
Citations
Cites
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Louis, E. D., & Ottman, R. (2014) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.198 · Cited by 193
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87
Zesiewicz, T. A., Chari, A., Jahan, I., Miller, A. M., & Sullivan, K. L. (2010) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s4795 · Cited by 87
Dynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81
Loureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70
Development of a Wearable Tremor Suppression Glove
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2018.8487197 · Cited by 61
An integrated wearable robot for tremor suppression with context aware sensing
Huen, D., Liu, J., & Lo, B. P. L. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516280 · Cited by 40
A soft wearable robot for tremor assessment and suppression
Gallego, J. Á., Rocón, E., Ibáñez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popović, M. B., Lois, J. M. B., Gianfelici, F., Farina, D., et al. (2011) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2011.5979639 · Cited by 39
Cited by
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“(61), who used pneumatic artificial muscles (PAMs) for suppressing hand tremor of ET patients due to the similar properties of these actuators with those of organic muscles.”
BackgroundMethodInfluentialSoft Gloves: A Review on Recent Developments in Actuation, Sensing, Control and Applications
Tiboni, M., & Amici, C. (2022) · Actuators · doi:10.3390/act11080232 · Cited by 38
Liu, G., Sun, N., Liang, D., Chen, Y., Yang, T., & Fang, Y. (2021) · Control Engineering Practice · doi:10.1016/j.conengprac.2021.104960 · Cited by 35
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 35
Bhidayasiri, R., Maytharakcheep, S., Phumphid, S., & Maetzler, W. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120197 · Cited by 28
Metadata
- Authors
- Skaramagkas, V., Andrikopoulos, G., & Manesis, S.
- Affiliations
- University of Patras (GR)
- Luleå University of Technology (SE)
- Venue
- 2020 European Control Conference (ECC)
- Publisher
- IEEE
- Published
- 2020-05
- Pages
- 889-894
- OpenAlex
- W3046871506
- Cited by
- 19
- References
- 21
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 1
- FWCI
- 4.99
- Type
- conference paper
- Language
- en
- Open access
- green
- urn.kb.se
- Licence
- other-oa
- Locations
- European Control Conference (ECC) (publishedVersion)
- KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- essential tremor, pneumatic artificial muscles, metacarpal region, force control, wearable rehabilitation device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Experimental Investigation of Essential Hand Tremor Suppression via a Soft Exoskeletal Glove. https://app.cochat.ai/papers/10.23919/ecc51009.2020.9143932
- The paper
- Skaramagkas, V., Andrikopoulos, G., & Manesis, S. (2020). An Experimental Investigation of Essential Hand Tremor Suppression via a Soft Exoskeletal Glove. 2020 European Control Conference (ECC). https://doi.org/10.23919/ecc51009.2020.9143932
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.