An Experimental Investigation of Essential Hand Tremor Suppression via a Soft Exoskeletal Glove
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
In this article, a soft exoskeletal glove is proposed for investigating the potential of utilizing Pneumatic Artificial Muscles (PAMs) for suppressing hand tremor of Essential Tremor (ET) patients. The glove setup is first presented from a conceptual point, which is focused on the dual investigation of applying local kinesthetic forces exerted via PAMs on the user's finger and on the metacarpal region. An experimental protocol is being derived incorporating a force controller adjusted for both investigated cases, while the efficiency of the proposed setup is extensively evaluated under various motion scenarios performed by an ET-diagnosed volunteer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“By using this force as the set point for a closed-loop controller, both prototypes obtained a maximal reduction of 75% in amplitude and 70% in frequency (61).”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“Using the prototypes under open-loop control, the authors obtained the force that provided the maximal decrease in tremor amplitude (89%) and frequency (70%) for one ET patient.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“Except for one of the reviewed works (61), the rest of them only presented experimental validations with healthy subjects or artificial platforms.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
In the citing paper
“As a result, there is yet a lack of proper validation of these actuators as a feasible solution for tremor management. In fact, only the soft exoskeletal glove presented by Skaramagkas et al. (61) presented a validation involving one actual ET patient.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [61]
Citations
Cites
Physiological and pathological tremors and rhythmic central motor control
McAuley, J. H. (2000) · Brain · doi:10.1093/brain/123.8.1545 · Cited by 509
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349
Louis, E. D., & Ottman, R. (2014) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.198 · Cited by 123
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87 · cited 1×
“Recent research attempts have included exoskeletons capable of reducing different tremor characteristics (amplitude, frequency) on different joints of the upper limbs: fingers ([6], [7]), wrist ([8], [9]), elbow ([10]–[13]), as well as multiple upper-limb joints ([14]–[16]).”
BackgroundDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81
Zesiewicz, T. (2010) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s4795 · Cited by 78
Loureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70 · cited 1×
“Recent research attempts have included exoskeletons capable of reducing different tremor characteristics (amplitude, frequency) on different joints of the upper limbs: fingers ([6], [7]), wrist ([8], [9]), elbow ([10]–[13]), as well as multiple upper-limb joints ([14]–[16]).”
BackgroundDevelopment of a Wearable Tremor Suppression Glove
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · 2018 7th IEEE International Conference on Biomedical Robotics and Biomechatronics (Biorob) · doi:10.1109/biorob.2018.8487197 · Cited by 55
An integrated wearable robot for tremor suppression with context aware sensing
Huen, D., Liu, J., & Lo, B. P. L. (2016) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2016.7516280 · Cited by 41
A soft wearable robot for tremor assessment and suppression
Gallego, J. A., Rocon, E., Ibanez, J., Dideriksen, J. L., Koutsou, A. D., Paradiso, R., Popovic, M. B., Belda-Lois, J. M., Gianfelici, F., Farina, D., et al. (2011) · 2011 IEEE International Conference on Robotics and Automation · doi:10.1109/icra.2011.5979639 · Cited by 38
Cited by
A Review on Wearable Technologies for Tremor Suppression
Lora-Millan, J. S., Delgado-Oleas, G., Benito-León, J., & Rocon, E. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.700600 · Cited by 62
“(61), who used pneumatic artificial muscles (PAMs) for suppressing hand tremor of ET patients due to the similar properties of these actuators with those of organic muscles.”
BackgroundMethodInfluentialSoft Gloves: A Review on Recent Developments in Actuation, Sensing, Control and Applications
Tiboni, M., & Amici, C. (2022) · Actuators · doi:10.3390/act11080232 · Cited by 45
Liu, G., Sun, N., Liang, D., Chen, Y., Yang, T., & Fang, Y. (2021) · Control Engineering Practice · doi:10.1016/j.conengprac.2021.104960 · Cited by 35
Design and Preliminary Performance Assessment of a Wearable Tremor Suppression Glove
Zhou, Y., Ibrahim, A. H., Hardy, K. G., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3080622 · Cited by 37
Bhidayasiri, R., Maytharakcheep, S., Phumphid, S., & Maetzler, W. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120197 · Cited by 28
A Layer Jamming Soft Glove for Hand Tremor Suppression
Wanasinghe, A. T., Awantha, W. V. I., Kavindya, A. G. P., Kulasekera, A. L., Chathuranga, D. S., & Senanayake, B. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3135497 · Cited by 24
A Wearable Finger Tremor-Suppression Orthosis Using the PVC Gel Linear Actuator
Liu, C., & Zhang, K. (2024) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2024.3369492 · Cited by 21
A Study on the Essential and Parkinson’s Arm Tremor Classification
Skaramagkas, V., Andrikopoulos, G., Kefalopoulou, Z. M., & Polychronopoulos, P. (2021) · Signals · doi:10.3390/signals2020016 · Cited by 22
“Finally, the inclusion of volunteers with more tremor types, for expanding this research direction towards the creation of a differential diagnostic tool, as well as the tool’s integration with tremor suppression methods involving soft exoskeletons [62] are also part of current and future work.”
BackgroundSelf-citationTowards Essential Hand Tremor Suppression via Pneumatic Artificial Muscles
Skaramagkas, V., Andrikopoulos, G., & Manesis, S. A. (2021) · Actuators · doi:10.3390/act10090206 · Cited by 15
“The presented approach, which extends the findings first shown in [25], provides novel insights on the efficiency and effect of these design differentiations on suppressing ET tremor.”
ResultSelf-citationTowards Differential Diagnosis of Essential and Parkinson's Tremor via Machine Learning
Skaramagkas, V., Andrikopoulos, G. K., Kefalopoulou, Z. M., & Polychronopoulos, P. (2020) · Mediterranean Conference on Control and Automation (MED) · doi:10.1109/med48518.2020.9182922 · Cited by 11
“…a detailed evaluation of utilizing machine learning to accurately identify between the two different tremor types, as well as an insight on the measurement points that provide better results in identifying tremor, for enabling future improvements on robot-enabled suppression techniques [25], [26].”
BackgroundSelf-citationShagan, A., Chase-Markopoulou, C., Walter, J. R., Sellhorn-Timm, J., Shao, Y., Nadler, T., Benson, A., Wochner, I., Rumley, E. H., Wurster, I., et al. (2025) · Device · doi:10.1016/j.device.2025.100719 · Cited by 9
Garcia-Higuera, J. A., Paredes-Acuña, N., Le, T., Auclair, B., Tomašković, K., Berberich, N., & Cheng, G. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304605 · Cited by 4
“These methods usually focus on detecting the tremor frequency and damping the movement components of these frequencies during a static activity [5], [6], [7], which serves well to suppress postural tremor.”
MethodLiu, G., Diao, S., Liu, Z., Zhang, X., Xiao, X. Q., Men, S., & Sun, N. (2024) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2024.3507281 · Cited by 3
“…are also fabric [10] and double-spring PAMs [11], twisting muscles [12], and hyperboloidal PAMs [13], etc. Based on these designs, PAM-actuated robots are able to tackle complex tasks, including bionic motions [14], gait rehabilitation [15], hand tremor suppression [16], and narrow space work [17].”
Tamás, E., Földi, S., Makk, Á., & Cserey, G. (2025) · Frontiers in Robotics and AI · doi:10.3389/frobt.2025.1537470 · Cited by 4
Mechatronic Devices for Upper Limb Tremor
Zhou, Y., Daemi, P., Edmonds, B. P. R., Habibollahi, Z., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2023) · Contemporary clinical neuroscience · doi:10.1007/978-3-031-26128-2_22 · Cited by 1
Developing a wearable device for upper extremity tremors
Yıldız, S. D., Akgün, G., Günal, D. İ., Kaplanoğlu, E., Aküner, M. C., & Sehirli, U. S. (2024) · Marmara medical journal · doi:10.5472/marumj.1483038 · Cited by 1
“Another study using a pneumatic actuator in a single ET patient reduced tremor magnitude by 70% [43].”
BackgroundViscous damping of tremor using a wearable robot with an optimized mechanical metamaterial
Kulkarni, S. R., Accoto, D., & Campolo, D. (2024) · Wearable Technologies · doi:10.1017/wtc.2024.15
Ghosh, R., Henry, C., Tauseef, M., & Sarkar, N. (2025) · Assistive Technology · doi:10.1080/10400435.2025.2580504
A Wearable Hand Tremor-Suppressing Glove Using PVC Gel-Based Actuators and Force Sensors
Liu, C., Wang, Y., & Zhang, K. (2026) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2026.3663307
Metadata
- Authors
- Skaramagkas, V., Andrikopoulos, G., & Manesis, S.
- Affiliations
- University of Patras (GR)
- Luleå University of Technology (SE)
- Venue
- 2020 European Control Conference (ECC)
- Publisher
- IEEE
- Published
- 2020-05
- Pages
- 889-894
- OpenAlex
- W3046871506
- Cited by
- 19
- References
- 21
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 4 · 2023: 2 · 2022: 2 · 2021: 6 · 2020: 1
- FWCI
- 4.99
- Type
- conference paper
- Language
- en
- Open access
- green
- urn.kb.se
- Licence
- other-oa
- Locations
- European Control Conference (ECC) (publishedVersion)
- KTH Publication Database DiVA (KTH Royal Institute of Technology) (submittedVersion, other-oa)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- essential tremor, pneumatic artificial muscles, metacarpal region, force control, wearable rehabilitation device
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.