Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 309

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound

Draper, David O., Castel, J. Chris, Castel, Dawn · 1995 · Journal of Orthopaedic & Sports Physical Therapy

Abstract

To achieve the thermal effects of ultrasound, the tissue temperature must be raised from 1 to > or = 4 degrees C, depending on the desired outcome of the treatment. In the past 25 years, there have been no in vivo studies that have measured rate of change in temperature during 1-MHz ultrasound treatments, and none have ever been performed with the 3-MHz frequency. Thus, we are left to pure speculation regarding how long to administer an ultrasound treatment. We performed this study to plot the rate of temperature increase during ultrasound treatments delivered at various intensities and frequencies. We inserted two 23-gauge thermistors into each subjects' medial triceps surae at the following depths: 1 MHz at depths of 2.5 and 5.0 cm (12 subjects) and 3 MHz at depths of .8 and 1.6 cm (12 subjects). Each subject received a total of four 10-minute treatments, one each at .5, 1.0, 1.5, and 2.0 W/cm2, and temperature was measured every 30 seconds. No significant difference was found in the rate of heating at the two depths (p = .987) within the same frequency and dose levels. The 3-MHz frequency heated significantly faster than the 1-MHz frequency at all doses tested (p < .001). On average, the rate of temperature increased per minute at the two depths of the 1-MHz frequency was: .04 degrees C at .5 W/cm2; .16 degrees C at 1.0 W/cm2; .33 degrees C at 1.5 W/cm2; and .38 degrees C at 2.0 W/cm2. The rate of temperature increase per minute at the two depths of the 3-MHz frequency was: .3 degrees C at .5 W/cm2; .58 degrees C at 1.0 W/cm2; .89 degrees C at 1.5 W/cm2; and 1.4 degrees C at 2.0 W/cm2. The results of this research should enable clinicians to choose the correct frequency, intensity, and treatment time when using thermal ultrasound.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2519/jospt.1995.22.4.142

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 309

Metadata

Authors
Draper, D. O., Castel, J. C., & Castel, D.
Venue
Journal of Orthopaedic & Sports Physical Therapy
Published
1995-10
Volume
22
Issue
4
Pages
142-150
ISSN
  • 0190-6011 (ISSN-L)
  • 1938-1344
OpenAlex
W2022432344
Cited by
309
References
6
FWCI
6.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound. https://app.cochat.ai/papers/10.2519/jospt.1995.22.4.142
The paper
Draper, D. O., Castel, J. C., & Castel, D. (1995). Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.1995.22.4.142

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.