The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound
Abstract
To achieve the thermal effects of ultrasound, the tissue temperature must be raised from 1 to > or = 4 degrees C, depending on the desired outcome of the treatment. In the past 25 years, there have been no in vivo studies that have measured rate of change in temperature during 1-MHz ultrasound treatments, and none have ever been performed with the 3-MHz frequency. Thus, we are left to pure speculation regarding how long to administer an ultrasound treatment. We performed this study to plot the rate of temperature increase during ultrasound treatments delivered at various intensities and frequencies. We inserted two 23-gauge thermistors into each subjects' medial triceps surae at the following depths: 1 MHz at depths of 2.5 and 5.0 cm (12 subjects) and 3 MHz at depths of .8 and 1.6 cm (12 subjects). Each subject received a total of four 10-minute treatments, one each at .5, 1.0, 1.5, and 2.0 W/cm2, and temperature was measured every 30 seconds. No significant difference was found in the rate of heating at the two depths (p = .987) within the same frequency and dose levels. The 3-MHz frequency heated significantly faster than the 1-MHz frequency at all doses tested (p < .001). On average, the rate of temperature increased per minute at the two depths of the 1-MHz frequency was: .04 degrees C at .5 W/cm2; .16 degrees C at 1.0 W/cm2; .33 degrees C at 1.5 W/cm2; and .38 degrees C at 2.0 W/cm2. The rate of temperature increase per minute at the two depths of the 3-MHz frequency was: .3 degrees C at .5 W/cm2; .58 degrees C at 1.0 W/cm2; .89 degrees C at 1.5 W/cm2; and 1.4 degrees C at 2.0 W/cm2. The results of this research should enable clinicians to choose the correct frequency, intensity, and treatment time when using thermal ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1965) · Annals of Internal Medicine · doi:10.7326/0003-4819-63-4-741_2 · Cited by 419
Incisional Wound Healing: A Controlled Study of Low and High Dose Ultrasound
Byl, N. N., McKenzie, A. L., Wong, T., West, J., & Hunt, T. K. (1993) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1993.18.5.619 · Cited by 100
Effect of ultrasound on tendon extensibility.
Jw, G. (1955) · PubMed · Cited by 77
Reversible Block of Nerve Conduction by Ultrasound: Ultrasonic Blocking of Nerve Fibers
Young, R. R. (1961) · Archives of Neurology · doi:10.1001/archneur.1961.00450070085009 · Cited by 58
Ultrasound in treatment of back pain resulting from prolapsed intervertebral disc.
Nwuga, V. C. B. (1983) · PubMed · Cited by 56
The biophysical basis of biologic ultrasonic reactions with special reference to ultrasonic therapy.
Jf, L. (1953) · PubMed · Cited by 42
Cited by
A Review of Therapeutic Ultrasound: Biophysical Effects
Baker, K. G., Robertson, V. J., & Duck, F. A. (2001) · Physical Therapy · doi:10.1093/ptj/81.7.1351 · Cited by 636
Ultrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Effects of temperature on neuromuscular electrophysiology
Rutkove, S. B. (2001) · Muscle & Nerve · doi:10.1002/mus.1084 · Cited by 288
Focused ultrasound for neuromodulation
Darrow, D. P. (2019) · Neurotherapeutics · doi:10.1007/s13311-018-00691-3 · Cited by 190
Ultrasonically triggered drug delivery: Breaking the barrier
Husseini, G. A., Pitt, W. G., & Martins, A. M. (2014) · Colloids and Surfaces B: Biointerfaces · doi:10.1016/j.colsurfb.2014.07.051 · Cited by 87
Metadata
- Authors
- Draper, D. O., Castel, J. C., & Castel, D.
- Venue
- Journal of Orthopaedic & Sports Physical Therapy
- Published
- 1995-10
- Volume
- 22
- Issue
- 4
- Pages
- 142-150
- ISSN
- 0190-6011 (ISSN-L)
- 1938-1344
- OpenAlex
- W2022432344
- Cited by
- 309
- References
- 6
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound. https://app.cochat.ai/papers/10.2519/jospt.1995.22.4.142
- The paper
- Draper, D. O., Castel, J. C., & Castel, D. (1995). Rate of Temperature Increase in Human Muscle During 1 MHz and 3 MHz Continuous Ultrasound. Journal of Orthopaedic & Sports Physical Therapy. https://doi.org/10.2519/jospt.1995.22.4.142
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.