CoChat

Clinical Measurement of Head and Shoulder Posture Variables

Harrison, Anne Leath, Barry-Greb, Theresa, Wojtowicz, Geralyn · 1996 · Journal of Orthopaedic & Sports Physical Therapy
Cited by 101

The DOI matches its Crossref record.

Abstract

A reliable method that is practical for clinical use for measuring head posture in standing has not been demonstrated in the literature. The purposes of this study were: 1) to produce a reliable method for measuring sagittal plane head and shoulder posture that is practical for clinical use and 2) to perform a pilot study to compare means between a nonpatient sample and a sample of people who have a history of recurring cervical pain. A method of measuring sagittal plane postural alignment of the head and shoulder in relationship to the lateral malleolus was developed using a carpenter's tri-square with a line level attached to the horizontal arm and a goniometer with a line level attached to the horizontal arm. Horizontal measures were taken with the tri-square from a vertical reference point to the tragus of the ear, to the shoulder axis, and to the lateral malleolus. Angular measures were taken with the goniometer of C7-tragus with the horizontal and tragus-corner of the eye with the horizontal. A reliability study was performed by two therapists with 15 non-patient subjects. Intraclass correlation coefficients measuring interrater reliability for horizontal and angular measures were as follows: 1) tragus to lateral malleolus: R = .87; 2) shoulder to lateral malleolus: R = .91;3) tragus to shoulder: R = .7;4) angle tragus-eye-horizon: R = .68; and 5) angle C7-tragus-horizon: R = .34. In the pilot study, 41 nonpatient subjects (11 males and 30 females, 20-45 years) and 10 patient subjects with cervical pain (one male and nine females, 23-43 years) were measured. Means calculated for horizontal distances (in cm) were: 1) tragus to lateral malleolus (nonpatients: 8.14; patients: 6.65);2) shoulder to lateral malleolus (nonpatients: 5.47; patients: 5.98); and 3) tragus to shoulder (nonpatients: 2.78; patients: .56). Means calculated for angular measures were: 1) tragus-eye-horizon (nonpatients: 18.78 degrees; patients: 21.57 degrees) and 2) C7-tragus-horizon (nonpatients: 49.34 degrees; patients: 49.43 degrees). No statistically significant differences were found between the two samples in this pilot study using an independent two-sample t test. This study demonstrates a reliable and practical method for taking postural measurements in the clinic and describes a pilot study for comparing a patient and a nonpatient sample.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2519/jospt.1996.23.6.353

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Harrison, A. L., Barry-Greb, T., & Wojtowicz, G.
Venue
Journal of Orthopaedic & Sports Physical Therapy
Published
1996-06
Volume
23
Issue
6
Pages
353-361
ISSN
  • 0190-6011 (ISSN-L)
  • 1938-1344
OpenAlex
W2072745612
Cited by
101
References
0
FWCI
1.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.