An alternative workflow for molecular detection of SARS-CoV-2 – escape from the NA extraction kit-shortage, Copenhagen, Denmark, March 2020
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
The World Health Organization has declared COVID-19 caused by the newly discovered SARS-CoV-2 a pandemic. Due to growing demand for reagents and/or kits to extract SARS-CoV-2 RNA for subsequent RT-qPCR diagnostics, there is a worldwide risk of shortages. With a detection sensitivity of 97.4% (95% CI: 86.2–99.9%), we describe a simple, fast, alternative workflow for molecular detection of SARS-CoV-2, where samples are simply heat-processed for 5 min at 98 °C before a commonly-used RT-qPCR procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344 · cited 1×
“Two SARS-CoV-2 RT-qPCR assays were used: (i) the published and widely used RT-qPCR assay for the envelope (E)-gene [4,5] combined with the SensiFAST Probe No-ROX One-Step Real-time PCR kit (Bioline Meridian BioScience, Cincinnati, Ohio, US), and (ii) the commercial RealStar SARS-CoV-2 RT-PCR kit 1.”
MethodWang, Y., Kang, H., Liu, X., & Tong, Z. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25721 · Cited by 454 · cited 1×
“In a period when the shortage in diagnostic kits in China occurred, the Chinese health institutions resorted to diagnosing COVID-19 in patients based on clinical symptoms alone, which resulted in a major peak in the reported cases on 12 February 2020 [7].”
BackgroundCOVID-19 in Singapore—Current Experience: Critical Global Issues That Require Attention and Action
Wong, J. E. L., Leo, Y. S., & Tan, C. C. (2020) · JAMA · doi:10.1001/jama.2020.2467 · Cited by 398 · cited 1×
“Because clinical symptoms for COVID-19 are sometimes non-specific (cough, mild fever, sore throat, fatigue), similar to other respiratory diseases or even absent despite infection [8,9], molecular testing for SARS-CoV-2 [9] is necessary for a more accurate diagnosis.”
BackgroundPatients with RT-PCR-confirmed COVID-19 and Normal Chest CT
Yang, W., & Yan, F. (2020) · Radiology · doi:10.1148/radiol.2020200702 · Cited by 210 · cited 1×
“To overcome this shortening of supplies, computerised tomography (CT) scans of lungs have been used for diagnosis, with mixed results and at a risk of false-negatives especially during the early onsets of symptoms [6].”
MethodClinical features and dynamics of viral load in imported and non-imported patients with COVID-19
Xu, T., Chen, C., Zhu, Z., Cui, M., Chen, C., Dai, H., & Xue, Y. (2020) · International Journal of Infectious Diseases · doi:10.1016/j.ijid.2020.03.022 · Cited by 193 · cited 1×
“Because clinical symptoms for COVID-19 are sometimes non-specific (cough, mild fever, sore throat, fatigue), similar to other respiratory diseases or even absent despite infection [8, 9], molecular testing for SARS-CoV-2 [9] is necessary for a more correct diagnosis.”
BackgroundKonrad, R., Eberle, U., Dangel, A., Treis, B., Berger, A., Bengs, K., Fingerle, V., Liebl, B., Ackermann, N., & Sing, A. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.9.2000173 · Cited by 158 · cited 1×
“Two SARS-CoV-2 RT-qPCR assays were used: (i) the published and widely used RT-qPCR assay for the envelope (E)-gene [4,5] combined with the SensiFAST Probe No-ROX One-Step Real-time PCR kit (Bioline Meridian BioScience, Cincinnati, Ohio, US), and (ii) the commercial RealStar SARS-CoV-2 RT-PCR kit 1.”
Method
Cited by
Korber, B., Fischer, W. M., Gnanakaran, S., Yoon, H., Theiler, J., Abfalterer, W., Hengartner, N., Giorgi, E. E., Bhattacharya, T., Foley, B., et al. (2020) · Cell · doi:10.1016/j.cell.2020.06.043 · Cited by 4,281
A colorimetric RT-LAMP assay and LAMP-sequencing for detecting SARS-CoV-2 RNA in clinical samples
Dao Thi, V. L., Herbst, K., Boerner, K., Meurer, M., Kremer, L. P., Kirrmaier, D., Freistaedter, A., Papagiannidis, D., Galmozzi, C., Stanifer, M. L., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.abc7075 · Cited by 673
Esbin, M. N., Whitney, O. N., Chong, S., Maurer, A., Darzacq, X., & Tjian, R. (2020) · RNA · doi:10.1261/rna.076232.120 · Cited by 477
Massive and rapid COVID-19 testing is feasible by extraction-free SARS-CoV-2 RT-PCR
Smyrlaki, I., Ekman, M., Lentini, A., Rufino de Sousa, N., Papanicolaou, N., Vondracek, M., Aarum, J., Safari, H., Muradrasoli, S., Rothfuchs, A. G., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-18611-5 · Cited by 457
Pham, Q.-V., Nguyen, D. C., Huynh-The, T., Hwang, W.-J., & Pathirana, P. N. (2020) · IEEE Access · doi:10.1109/access.2020.3009328 · Cited by 413
“In response to the COVID-19 virus, some efforts have been dedicated to improve this technique [36] and for other alternatives [37].”
Background
Metadata
- Authors
- Fomsgaard, A. S., & Rosenstierne, M. W.
- Venue
- Eurosurveillance
- Published
- 2020-04-09
- Volume
- 25
- Issue
- 14
- ISSN
- 1025-496X (ISSN-L)
- 1560-7917
- OpenAlex
- W3015530494
- Cited by
- 184
- References
- 6
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.