Design and Implementation of an Automated Partial Volume Correction in PET: Application to Dopamine Receptor Quantification in the Normal Human Striatum
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The considerable effort and potential lack of reproducibility of human-driven PET quantification and partial volume correction (PVC) can be alleviated by use of atlas-based automatic analysis. The present study examined the application of a new algorithm designed to automatically define 3-dimensional regions of interest (ROIs) and their effect on dopamine receptor quantification in the normal human brain striatum, both without and with PVC. METHODS: A total of 90 healthy volunteers (age range, 18-46 y) received a single injection of (11)C-raclopride, and automatic segmentation of concomitant structural MR images was performed using a maximum-probability atlas in combination with a trained neural network. For each identified tissue segment considered homogeneous for the tracer (or volumes of interest [VOIs]), an a priori criterion based on minimum axial recovery coefficient (RC(zmin) = 50%, 75%, and 90%) was used to constrain the extent of each ROI. RESULTS: With ROIs essentially overlapping the entire VOI volume (obtained with RC(zmin) = 50%), the binding potential (BP(ND)) of (11)C-raclopride was found to be around 2.2 for caudate and 2.9 for putamen, an underestimation by 35% and 28%, respectively, according to PVC values. At increased RC(zmin), BP(ND) estimates of (11)C-raclopride were increased by 12% and 21% for caudate and 8% and 15% for putamen when the associated ROIs decreased to around 65% and 43% of total tissue volume (VOI) for caudate and 67% and 31% for putamen. After PVC, we observed relative increases in BP(ND) variance of 12% for caudate and 20% for putamen, whereas estimated BP(ND) values all increased to 3.4 for caudate and 4.0 for putamen, regardless of ROI size. Dopamine receptor concentrations appeared less heterogeneous in the normal human striatum after PVC than they did without PVC: the 25%-30% difference in BP(ND) estimates observed between caudate and putamen remained significant after PVC but was reduced to slightly less than 20%. Furthermore, the results were comparable with those obtained with a manual method currently in use in our laboratory. CONCLUSION: The new algorithm allows for traditional PET data extraction and PVC in an entirely automatic fashion, thus avoiding labor-intensive analyses and potential intra- or interobserver variability. This study also offers the first, to our knowledge, large-scale application of PVC to dopamine D(2)/D(3) receptor imaging with (11)C-raclopride in humans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547 · cited 1×
“This final step was performed according to spatial MRI/PET normalization through mutual information (16), together with the previously computed transformations used for the MRI spatial normalization.”
MethodConsensus Nomenclature for in vivo Imaging of Reversibly Binding Radioligands
Innis, R. B., Cunningham, V. J., Delforge, J., Fujita, M., Gjedde, A., Gunn, R. N., Holden, J., Houle, S., Huang, S.-C., Ichise, M., et al. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600493 · Cited by 1,955
Self-citationVolkow, N. D., Wang, G., Fowler, J. S., Logan, J., Jayne, M., Franceschi, D., Wong, C., Gatley, S. J., Gifford, A. N., Ding, Y., et al. (2002) · Synapse · doi:10.1002/syn.10075 · Cited by 452 · cited 1×
“BPND Before PVC, the present estimates of BPND in healthy subjects (Table 3) are in the range of earlier estimates (31,32).”
ResultZaidi, H., Ruest, T., Schoenahl, F., & Montandon, M.-L. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.031 · Cited by 108 · cited 1×
“Still, the choice of the imagesegmentation method remains the most critical aspect of PVC accuracy and is an active field of research (26).”
Method
Cited by
LaMontagne, P. J., Benzinger, T. L., Morris, J. C., Keefe, S., Hornbeck, R., Xiong, C., Grant, E., Hassenstab, J., Moulder, K., Vlassenko, A. G., et al. (2019) · medRxiv · doi:10.1101/2019.12.13.19014902 · Cited by 779
Partial volume correction in quantitative amyloid imaging
Su, Y., Blazey, T. M., Snyder, A. Z., Raichle, M. E., Marcus, D. S., Ances, B. M., Bateman, R. J., Cairns, N. J., Aldea, P., Cash, L., et al. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.11.058 · Cited by 247
Utilizing the Centiloid scale in cross-sectional and longitudinal PiB PET studies
Su, Y., Flores, S., Hornbeck, R. C., Speidel, B., Vlassenko, A. G., Gordon, B. A., Koeppe, R. A., Klunk, W. E., Xiong, C., Morris, J. C., et al. (2018) · NeuroImage: Clinical · doi:10.1016/j.nicl.2018.04.022 · Cited by 126
Reduced Synaptic Density in Patients with Lewy Body Dementia: An [ 11 C ] UCB‐J PET Imaging Study
Andersen, K. B., Hansen, A. K., Damholdt, M. F., Horsager, J., Skjærbæk, C., Gottrup, H., Klit, H., Schacht, A. C., Danielsen, E. H., Brooks, D. J., et al. (2021) · Movement Disorders · doi:10.1002/mds.28617 · Cited by 84
Su, Y., Blazey, T. M., Owen, C. J., Christensen, J. J., Friedrichsen, K., Joseph-Mathurin, N., Wang, Q., Hornbeck, R. C., Ances, B. M., Snyder, A. Z., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0152082 · Cited by 56
“PVC was also performed using a regional spread function (RSF) technique implemented in PUP [18], which is also known as the geometric transfer matrix (GTM) technique [33].”
Method
Metadata
- Authors
- Rousset, O. G., Collins, D. L., Rahmim, A., & Wong, D. F.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-06-13
- Volume
- 49
- Issue
- 7
- Pages
- 1097-1106
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2055069465
- Cited by
- 106
- References
- 4
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.