The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
MRI-Based Attenuation Correction for PET/MRI: A Novel Approach Combining Pattern Recognition and Atlas Registration
Open accessAbstract
UNLABELLED: For quantitative PET information, correction of tissue photon attenuation is mandatory. Generally in conventional PET, the attenuation map is obtained from a transmission scan, which uses a rotating radionuclide source, or from the CT scan in a combined PET/CT scanner. In the case of PET/MRI scanners currently under development, insufficient space for the rotating source exists; the attenuation map can be calculated from the MR image instead. This task is challenging because MR intensities correlate with proton densities and tissue-relaxation properties, rather than with attenuation-related mass density. METHODS: We used a combination of local pattern recognition and atlas registration, which captures global variation of anatomy, to predict pseudo-CT images from a given MR image. These pseudo-CT images were then used for attenuation correction, as the process would be performed in a PET/CT scanner. RESULTS: For human brain scans, we show on a database of 17 MR/CT image pairs that our method reliably enables estimation of a pseudo-CT image from the MR image alone. On additional datasets of MRI/PET/CT triplets of human brain scans, we compare MRI-based attenuation correction with CT-based correction. Our approach enables PET quantification with a mean error of 3.2% for predefined regions of interest, which we found to be clinically not significant. However, our method is not specific to brain imaging, and we show promising initial results on 1 whole-body animal dataset. CONCLUSION: This method allows reliable MRI-based attenuation correction for human brain scans. Further work is necessary to validate the method for whole-body imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gaussian Processes for Machine Learning
Rasmussen, C. E., & Williams, C. K. I. (2005) · doi:10.7551/mitpress/3206.001.0001 · Cited by 11,705
Learning with Kernels: Support Vector Machines, Regularization, Optimization, and Beyond
Schölkopf, B., & Smola, A. J. (2001) · The MIT Press eBooks · doi:10.7551/mitpress/4175.001.0001 · Cited by 11,703
Self-citationZhang, Y., Brady, M., & Smith, S. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.906424 · Cited by 6,982
Self-citationA global optimisation method for robust affine registration of brain images
Jenkinson, M., & Smith, S. (2001) · Medical Image Analysis · doi:10.1016/s1361-8415(01)00036-6 · Cited by 6,872
What is a support vector machine?
Noble, W. S. (2006) · Nature Biotechnology · doi:10.1038/nbt1206-1565 · Cited by 4,301
Spatial registration and normalization of images
Friston, K. J., Ashburner, J., Frith, C. D., Poline, J. ‐., Heather, J. D., & Frackowiak, R. S. J. (1995) · Human Brain Mapping · doi:10.1002/hbm.460030303 · Cited by 3,744
Gonzalez, R. C., & Woods, R. E. (1977) · SDÜ Bilgi Merkezi · Cited by 3,736
Automatic classification of MR scans in Alzheimer’s disease.
Kloppel, S., Stonnington, C. M., Chu, C., Draganski, B., Scahill, R. I., Rohrer, J. D., Fox, N. C., Jack, C. R., Ashburner, J., & Frackowiak, R. S. J. (2008) · Brain · doi:10.1093/brain/awm319 · Cited by 1,170
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Self-citationAttenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 1×
“PET AC has been investigated extensively by numerous authors (22,23).”
BackgroundCatana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Self-citationImage-based multivariate profiling of drug responses from single cells
Loo, L.-H., Wu, L. F., & Altschuler, S. J. (2007) · Nature Methods · doi:10.1038/nmeth1032 · Cited by 343
Method for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271
Zaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233
Clinical ultrashort echo time imaging of bone and other connective tissues
Robson, M. D., & Bydder, G. M. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1100 · Cited by 213
Statistical parametric mapping (SPM)
Flandin, G., & Friston, K. (2008) · Scholarpedia · doi:10.4249/scholarpedia.6232 · Cited by 180
PET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet
Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., Cherry, S. R., Claussen, C. D., & Pichler, B. J. (2007) · Radiology · doi:10.1148/radiol.2443061756 · Cited by 173
Self-citationWatershed-based segmentation of 3D MR data for volume quantization
Sijbers, J., Scheunders, P., Verhoye, M., der Linden, A. V., Dyck, D. V., & Raman, E. R. (1997) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00033-7 · Cited by 154
Attenuation correction for small animal PET tomographs
Chow, P. L., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/014 · Cited by 145
Segmentation of skull and scalp in 3‐D human MRI using mathematical morphology
Dogdas, B., Shattuck, D. W., & Leahy, R. M. (2005) · Human Brain Mapping · doi:10.1002/hbm.20159 · Cited by 143
Computational approaches to network analysis in functional brain imaging
Gonzalez-Lima, F., McIntosh, A. R., & Fox, P. T. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020103 · Cited by 139
MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
Beyer, T., Weigert, M., Quick, H. H., Pietrzyk, U., VOGT, F. M., Palm, C., Antoch, G., Müller, S. P., & Bockisch, A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0734-0 · Cited by 102
Exploring functional relationships between components of the gene expression machinery
Burckin, T., Nagel, R., Mandel‐Gutfreund, Y., Shiue, L., Clark, T. A., Chong, J.-L., Chang, T., Squazzo, S. L., Hartzog, G. A., & Ares, M. (2005) · Nature Structural & Molecular Biology · doi:10.1038/nsmb891 · Cited by 96
Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?
Zaidi, H. (2007) · Radiology · doi:10.1148/radiol.2443070092 · Cited by 80
Alternative methods for attenuation correction for PET images in MR-PET scanners
Kops, E. R., & Herzog, H. (2007) · 2006 IEEE Nuclear Science Symposium Conference Record · doi:10.1109/nssmic.2007.4437073 · Cited by 80
MRI-Guided SPECT Perfusion Measures and Volumetric MRI in Prodromal Alzheimer Disease
Fakhri, G. E., Kijewski, M. F., Johnson, K. A., Syrkin, G., Killiany, R., Becker, J. A., Zimmerman, R. E., & Albert, M. (2003) · Archives of Neurology · doi:10.1001/archneur.60.8.1066 · Cited by 72
Fast methods for including attenuation in the EM algorithm
Hebert, T. J., & Leahy, R. M. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106710 · Cited by 64
Strategies for attenuation compensation in neurological PET studies
Zaidi, H., Montandon, M., & Meikle, S. R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.002 · Cited by 54
Bai, C., Kinahan, P. E., Brasse, D., et al. (2003) · PubMed · Cited by 46
Fakhri, G. N. E., Kijewski, M. F., & Moore, S. C. (2001) · IEEE Transactions on Nuclear Science · doi:10.1109/23.940161 · Cited by 16
Cited by
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Medical Image Synthesis with Deep Convolutional Adversarial Networks
Nie, D., Trullo, R., Lian, J., Wang, L., Petitjean, C., Ruan, S., Wang, Q., & Shen, D. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2814538 · Cited by 625
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508
Simultaneous MR/PET Imaging of the Human Brain: Feasibility Study
Schlemmer, H.-P. W., Pichler, B. J., Schmand, M., Burbar, Z., Michel, C., Ladebeck, R., Jattke, K., Townsend, D., Nahmias, C., Jacob, P. K., et al. (2008) · Radiology · doi:10.1148/radiol.2483071927 · Cited by 474
Self-citation
Metadata
- Authors
- Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-10-16
- Volume
- 49
- Issue
- 11
- Pages
- 1875-1883
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2100495482
- Cited by
- 495
- References
- 30
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.