Treatment Monitoring by 18F-FDG PET/CT in Patients with Sarcomas: Interobserver Variability of Quantitative Parameters in Treatment-Induced Changes in Histopathologically Responding and Nonresponding Tumors
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Measurements of tumor glucose use by (18)F-FDG PET need to be standardized within and across institutions. Various parameters are used for measuring changes in tumor glucose metabolic activity with (18)F-FDG PET in response to cancer treatments. However, it is unknown which of these provide the lowest variability between observers. Knowledge of the interobserver variability of quantitative parameters is important in sarcomas as these tumors are frequently large and demonstrate heterogeneous (18)F-FDG uptake. METHODS: A total of 33 patients (16 men, 17 women; mean age, 47 +/- 18 y) with high-grade sarcomas underwent (18)F-FDG PET/CT scans before and after neoadjuvant chemotherapy. Two independent investigators measured the following parameters on the pretreatment and posttreatment scans: maximum standardized uptake value (SUVmax), peak SUV (SUVpeak), mean SUV (SUVmean), SUVmean in an automatically defined volume (SUVauto), and tumor-to-background ratio (TBR). The variability of the different parameters was compared by concordance correlation coefficient (CCC), variability effect coefficient, and Bland-Altman plots. RESULTS: Baseline SUVmax, SUVpeak, SUVmean, SUVauto, and TBR averaged 10.36, 7.78, 4.13, and 6.22 g/mL and 14.67, respectively. They decreased to 5.36, 3.80, 1.79, and 3.25 g/mL and 6.62, respectively, after treatment. SUVmax, SUVpeak, and SUVauto measurements and their changes were reproducible (CCC > or = 0.98). However, SUVauto poorly differentiated between responding and nonresponding tumors. The high intratumoral heterogeneity of (18)F-FDG resulted in frequent failure of the thresholding algorithm, which necessitated manual corrections that in turn resulted in a higher interobserver variability of SUVmean (CCCs for follow-up and change were 0.96 and 0.91, respectively; P < 0.005). TBRs also showed a significantly higher variability than did SUVpeak (CCCs for follow-up and change were 0.94 and 0.86, respectively; P < 0.005). CONCLUSION: SUVmax and SUVpeak provided the most robust measurements of tumor glucose metabolism in sarcomas. Delineation of the whole-tumor volume by semiautomatic thresholding did not decrease the variability of SUV measurements. TBRs were significantly more observer-dependent than were absolute SUVs. These findings should be considered for standardization of clinical (18)F-FDG PET/CT trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785 · cited 12×
“The high interobserver variability of SUVmean may appear surprising, because SUVmax measurements were TABLE 2 CCC, SD of Differences, and Comparison Between CCCs Parameter CCC Lower 95% CI for CCC SD of differences P (comparing 2 CCCs) Baseline SUVmax 1.00 1.00 0.00 SUVpeak 0.99 0.99 0.68 ,0.005* SUVmean 0.84 0.71 1.4…”
MethodInfluential
Cited by
A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662
18F-FDG PET and PET/CT in the Evaluation of Cancer Treatment Response
Ben-Haim, S., & Ell, P. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054205 · Cited by 351
Benz, M. R., Czernin, J., Dry, S. M., Tap, W. D., Allen‐Auerbach, M. S., Elashoff, D., Phelps, M. E., Weber, W. A., & Eilber, F. C. (2010) · Cancer · doi:10.1002/cncr.24755 · Cited by 201
“SUVmax was used as a measure of tumor glucose utilization, as this parameter allows the best comparison between studies because of high reproducibility and low interobserver variability.(17)”
MethodSelf-citationInstrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82
SUV and segmentation: pressing challenges in tumour assessment and treatment
Lucignani, G. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1085-1 · Cited by 38
Two-Time-Point FDG PET/CT: Liver SULmean Repeatability
Tahari, A. K., Paidpally, V., Chirindel, A., Wahl, R. L., & Subramaniam, R. M. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12719 · Cited by 10
“It has been proposed that 18FFDG accumulation in a malignant lesion be compared with the background uptake in the liver parenchyma [9–11].”
Background
Metadata
- Authors
- Benz, M. R., Evilevitch, V., Allen-Auerbach, M. S., Eilber, F. C., Phelps, M. E., Czernin, J., & Weber, W. A.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2008-06-13
- Volume
- 49
- Issue
- 7
- Pages
- 1038-1046
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2168725615
- Cited by
- 108
- References
- 2
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.