The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Tissue Classification as a Potential Approach for Attenuation Correction in Whole-Body PET/MRI: Evaluation with PET/CT Data
Open accessAbstract
UNLABELLED: Attenuation correction (AC) of whole-body PET data in combined PET/MRI tomographs is expected to be a technical challenge. In this study, a potential solution based on a segmented attenuation map is proposed and evaluated in clinical PET/CT cases. METHODS: Segmentation of the attenuation map into 4 classes (background, lungs, fat, and soft tissue) was hypothesized to be sufficient for AC purposes. The segmentation was applied to CT-based attenuation maps from (18)F-FDG PET/CT oncologic examinations of 35 patients with 52 (18)F-FDG-avid lesions in the lungs (n = 15), bones (n = 21), and neck (n = 16). The standardized uptake values (SUVs) of the lesions were determined from PET images reconstructed with nonsegmented and segmented attenuation maps, and an experienced observer interpreted both PET images with no knowledge of the attenuation map status. The feasibility of the method was also evaluated with 2 patients who underwent both PET/CT and MRI. RESULTS: The use of a segmented attenuation map resulted in average SUV changes of 8% +/- 3% (mean +/- SD) for bone lesions, 4% +/- 2% for neck lesions, and 2% +/- 3% for lung lesions. The largest SUV change was 13.1%, for a lesion in the pelvic bone. There were no differences in the clinical interpretations made by the experienced observer with both types of attenuation maps. CONCLUSION: A segmented attenuation map with 4 classes derived from CT data had only a small effect on the SUVs of (18)F-FDG-avid lesions and did not change the interpretation for any patient. This approach appears to be practical and valid for MRI-based AC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Whole-Body Dual-Modality PET/CT and Whole-Body MRI for Tumor Staging in Oncology
Antoch, G. (2003) · JAMA · doi:10.1001/jama.290.24.3199 · Cited by 551
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
Simultaneous MR/PET Imaging of the Human Brain: Feasibility Study
Schlemmer, H.-P. W., Pichler, B. J., Schmand, M., Burbar, Z., Michel, C., Ladebeck, R., Jattke, K., Townsend, D., Nahmias, C., Jacob, P. K., et al. (2008) · Radiology · doi:10.1148/radiol.2483071927 · Cited by 474
Reproducibility of metabolic measurements in malignant tumors using FDG PET.
Weber, W., Ziegler, S. I., Thödtmann, R., Hanauske, A.-R., & Schwaiger, M. (1999) · PubMed · Cited by 388
Self-citationCatana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Multiple Myeloma: Clinical Review and Diagnostic Imaging
Angtuaco, E. J. C., Fassas, A. B. T., Walker, R., Sethi, R., & Barlogie, B. (2004) · Radiology · doi:10.1148/radiol.2311020452 · Cited by 299
Beyer, T., Antoch, G., Blodgett, T., Freudenberg, L. F., Akhurst, T., & Mueller, S. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1097-6 · Cited by 298
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711622105 · Cited by 272
Minn, H., Zasadny, K. R., Quint, L. E., & Wahl, R. L. (1995) · Radiology · doi:10.1148/radiology.196.1.7784562 · Cited by 260
Zaidi, H., Montandon, M.-L., & Slosman, D. O. (2003) · Medical Physics · doi:10.1118/1.1569270 · Cited by 233
Flows of diffeomorphisms for multimodal image registration
Chefd'hotel, C., Hermosillo, G., & Faugeras, O. (2003) · Proceedings IEEE International Symposium on Biomedical Imaging · doi:10.1109/isbi.2002.1029367 · Cited by 174
Self-citationPET/MR Images Acquired with a Compact MR-compatible PET Detector in a 7-T Magnet
Judenhofer, M. S., Catana, C., Swann, B. K., Siegel, S. B., Jung, W.-I., Nutt, R. E., Cherry, S. R., Claussen, C. D., & Pichler, B. J. (2007) · Radiology · doi:10.1148/radiol.2443061756 · Cited by 173
18F-FDG PET/CT, 99mTc-MIBI, and MRI in Evaluation of Patients with Multiple Myeloma
Fonti, R., Salvatore, B., Quarantelli, M., Sirignano, C., Segreto, S., Petruzziello, F., Catalano, L., Liuzzi, R., Rotoli, B., Del Vecchio, S., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045641 · Cited by 173
Martínez-Möller, A., Souvatzoglou, M., Navab, N., Schwaiger, M., & Nekolla, S. G. (2007) · PubMed · Cited by 166
Self-citationNakamoto, Y., Osman, M., Cohade, C., Marshall, L. T., Links, J. M., Kohlmyer, S. G., & Wahl, R. L. (2002) · PubMed · Cited by 161
(2005) · PubMed · Cited by 156
Quantifying the Effect of IV Contrast Media on Integrated PET/CT: Clinical Evaluation
Mawlawi, O. R., Erasmus, J. J., Munden, R. F., Pan, T., Knight, A. E., Macapinlac, H. A., Podoloff, D. A., & Chasen, M. H. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.04.1740 · Cited by 143
Two‐point Dixon technique for water‐fat signal decomposition with B0 inhomogeneity correction
Coombs, B. D., Szumowski, J., & Coshow, W. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380606 · Cited by 127
Effects of Nonionic Intravenous Contrast Agents at PET/CT Imaging: Phantom and Canine Studies
Nakamoto, Y., Chin, B. B., Kraitchman, D. L., Lawler, L. P., Marshall, L. T., & Wahl, R. L. (2003) · Radiology · doi:10.1148/radiol.2273020299 · Cited by 111
MR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
Beyer, T., Weigert, M., Quick, H. H., Pietrzyk, U., VOGT, F. M., Palm, C., Antoch, G., Müller, S. P., & Bockisch, A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0734-0 · Cited by 102
Metabolic and molecular imaging in neuro-oncology
Herholz, K., Coope, D. J., & Jackson, A. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(07)70192-8 · Cited by 100
Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?
Zaidi, H. (2007) · Radiology · doi:10.1148/radiol.2443070092 · Cited by 80
Impact of FDG-PET/MRI Image Fusion on the Detection of Pancreatic Cancer
Ruf, J., HÄNNINEN, E. L., Böhmig, M., Koch, I., Denecke, T., Plotkin, M., Langrehr, J. M., Wiedenmann, B. J., FELIX, R., & Amthauer, H. (2006) · Pancreatology · doi:10.1159/000096993 · Cited by 51
Image Registration of Structural and Physiological MR Images of Abnormal Anatomy
Mang, A., Cámara, Ó., Caseiras, G. B., Crum, W. R., Schnabel, J. A., Buzug, T. M., Thornton, J. S., Jäger, H. R., & Hawkes, D. J. (2007) · Springer eBooks · doi:10.1007/978-3-540-68764-1_35 · Cited by 24
Cited by
MR-based synthetic CT generation using a deep convolutional neural network method
Han, X. (2017) · Medical Physics · doi:10.1002/mp.12155 · Cited by 711
Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.098608 · Cited by 508
Self-citationAdvances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
PET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418
Deep Learning MR Imaging–based Attenuation Correction for PET/MR Imaging
Liu, F., Jang, H., Kijowski, R., Bradshaw, T., & McMillan, A. B. (2018) · Radiology · doi:10.1148/radiol.2017170700 · Cited by 412
Metadata
- Authors
- Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2009-03-16
- Volume
- 50
- Issue
- 4
- Pages
- 520-526
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2167157872
- Cited by
- 712
- References
- 26
- FWCI
- 16.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.