CoChat

Imaging and Quantitation of Cannabinoid CB1 Receptors in Human and Monkey Brains Using 18F-Labeled Inverse Agonist Radioligands

Open access
Terry, Garth E., Hirvonen, Jussi, Liow, Jeih-San, Zoghbi, Sami S., Gladding, Robert, Tauscher, Johannes T., Schaus, John M., Phebus, Lee, Felder, Christian C., Morse, Cheryl L., Donohue, Sean R., Pike, Victor W., Halldin, Christer, Innis, Robert B. · 2010 · Journal of Nuclear Medicine
Cited by 101

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

UNLABELLED: We recently demonstrated that (11)C-MePPEP, a PET ligand for CB(1) receptors, has such high uptake in the human brain that it can be imaged for 210 min and that receptor density can be quantified as distribution volume (V(T)) using the gold standard of compartmental modeling. However, (11)C-MePPEP had relatively poor retest and intersubject variabilities, which were likely caused by errors in the measurements of radioligand in plasma at low concentrations by 120 min. We sought to find an analog of (11)C-MePPEP that would provide more accurate plasma measurements. We evaluated several promising analogs in the monkey brain and chose the (18)F-di-deutero fluoromethoxy analog ((18)F-FMPEP-d(2)) to evaluate further in the human brain. METHODS: (11)C-FMePPEP, (18)F-FEPEP, (18)F-FMPEP, and (18)F-FMPEP-d(2) were studied in 5 monkeys with 10 PET scans. We calculated V(T) using compartmental modeling with serial measurements of unchanged parent radioligand in arterial plasma and radioactivity in the brain. Nonspecific binding was determined by administering a receptor-saturating dose of rimonabant, an inverse agonist at the CB(1) receptor. Nine healthy human subjects participated in 17 PET scans using (18)F-FMPEP-d(2), with 8 subjects having 2 PET scans to assess retest variability. To identify sources of error, we compared intersubject and retest variability of brain uptake, arterial plasma measurements, and V(T). RESULTS: (18)F-FMPEP-d(2) had high uptake in the monkey brain, with greater than 80% specific binding, and yielded less radioactivity uptake in bone than did (18)F-FMPEP. High brain uptake with (18)F-FMPEP-d(2) was also observed in humans, in whom V(T) was well identified within approximately 60 min. Retest variability of plasma measurements was good (16%); consequently, V(T) had a good retest variability (14%), intersubject variability (26%), and intraclass correlation coefficient (0.89). V(T) increased after 120 min, suggesting an accumulation of radiometabolites in the brain. Radioactivity accumulated in the skull throughout the entire scan but was thought to be an insignificant source of data contamination. CONCLUSION: Studies in monkeys facilitated our development and selection of (18)F-FMPEP-d(2), compared with (18)F-FMPEP, as a radioligand demonstrating high brain uptake, high percentage of specific binding, and reduced uptake in bone. Retest analysis in human subjects showed that (18)F-FMPEP-d(2) has greater precision and accuracy than (11)C-MePPEP, allowing smaller sample sizes to detect a significant difference between groups.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.109.067074

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Terry, G. E., Hirvonen, J., Liow, J.-S., Zoghbi, S. S., Gladding, R., Tauscher, J. T., Schaus, J. M., Phebus, L., Felder, C. C., Morse, C. L., Donohue, S. R., Pike, V. W., Halldin, C., & Innis, R. B.
Venue
Journal of Nuclear Medicine
Published
2009-12-15
Volume
51
Issue
1
Pages
112-120
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2081629269
Cited by
101
References
4
FWCI
4.27
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.