CoChat

Quantification of Smoking-Induced Occupancy of β2-Nicotinic Acetylcholine Receptors: Estimation of Nondisplaceable Binding

Open access
Esterlis, Irina, Cosgrove, Kelly P., Batis, Jeffery C., Bois, Frederic, Stiklus, Stephanie M., Perkins, Evgenia, Seibyl, John P., Carson, Richard E., Staley, Julie K. · 2010 · Journal of Nuclear Medicine
Cited by 36

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

UNLABELLED: 5-(123)I-iodo-85380 ((123)I-5-IA) is used to quantitate high-affinity nicotinic acetylcholine receptors (beta(2)-nAChRs) on human SPECT scans. The primary outcome measure is V(T)/f(P), the ratio at equilibrium between total tissue concentration (free, nonspecifically bound, and specifically bound) and the free plasma concentration. Nondisplaceable uptake (free plus nonspecific) of (123)I-5-IA has not been measured in human subjects. Nicotine has high affinity for beta(2)*-nAChRs (nAChRs containing the beta(2)* subunit, for which * represents other subunits that may also be part of the receptor) and displaces specifically bound (123)I-5-IA. In this study, we measured nicotine occupancy and nondisplaceable binding in healthy smokers after they had smoked to satiety. METHODS: Eleven nicotine-dependent smokers (mean age +/- SD, 35.6 +/- 14.4 y) completed the study. One subject was excluded from subsequent analyses because of abnormal blood nicotine levels. Subjects abstained from tobacco smoke for 5.3 +/- 0.9 d and participated in a 15- to 17-h SPECT scanning day. (123)I-5-IA was administered by bolus plus constant infusion, with a total injected dose of 361 +/- 20 MBq. At approximately 6 h after the start of the infusion, three 30-min SPECT scans and a 15-min transmission-emission scan were acquired to obtain baseline beta(2)*-nAChR availability. Subjects then smoked to satiety (2.4 +/- 0.7 cigarettes), and arterial (first 40 min) and venous (until study completion) plasma nicotine and cotinine levels were collected. About 1 h after subjects had smoked to satiety, up to six 30-min SPECT scans were acquired. V(T)/f(P) data, computed from the tissue and plasma radioactivity measurements from the presmoking baseline and postsmoking scans, were analyzed using the Lassen plot method. RESULTS: Receptor occupancy after subjects had smoked to satiety was 67% +/- 9% (range, 55%-80%). Nondisplaceable uptake was estimated as 19.4 +/- 5.8 mL x cm(-3) (range, 15-28 mL x cm(-3)). Thus, in the thalamus, where mean V(T)/f(P) is 93 mL x cm(-3), nondisplaceable binding represents approximately 20% of the total binding. CONCLUSION: These results are in agreement with previous findings and suggest that when satiating doses of nicotine are administered to smokers, imaging of receptor availability can yield valuable data, such as quantifiable measures of nondisplaceable binding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.109.072447

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Esterlis, I., Cosgrove, K. P., Batis, J. C., Bois, F., Stiklus, S. M., Perkins, E., Seibyl, J. P., Carson, R. E., & Staley, J. K.
Venue
Journal of Nuclear Medicine
Published
2010-07-21
Volume
51
Issue
8
Pages
1226-1233
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2160614932
Cited by
36
References
10
FWCI
2.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.