First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
Open accessAbstract
UNLABELLED: The recently introduced first integrated whole-body PET/MR scanner allows simultaneous acquisition of PET and MRI data in humans and, thus, may offer new opportunities, particularly regarding diagnostics in oncology. This scanner features major technologic differences from conventional PET/CT devices, including the replacement of photomultipliers with avalanche photodiodes and the need for MRI-based attenuation correction. The aim of this study was to evaluate the comparability of clinical performance between conventional PET/CT and PET/MR in patients with oncologic diseases. METHODS: Thirty-two patients with different oncologic diagnoses underwent a single-injection, dual-imaging protocol consisting of a PET/CT and subsequent PET/MR scan. PET/CT scans were performed according to standard clinical protocols (86 ± 8 min after injection of 401 ± 42 MBq of (18)F-FDG, 2 min/bed position). Subsequently (140 ± 24 min after injection), PET/MR was performed (4 min/bed position). PET images of both modalities were reconstructed iteratively. Attenuation and scatter correction as well as regional allocation of PET findings were performed using low-dose CT data for PET/CT and Dixon MRI sequences for PET/MR. PET/MR and PET/CT were compared visually by 2 teams of observers by rating the number and location of lesions suspicious for malignancy, as well as image quality and alignment. For quantitative comparison, standardized uptake values (SUVs) of the detected lesions and of different tissue types were assessed. RESULTS: Simultaneous PET/MR acquisition was feasible with high quality in short acquisition time (≤ 20 min). No significant difference was found between the numbers of suspicious lesions (n = 80) or lesion-positive patients (n = 20) detected with PET/MR or PET/CT. Anatomic allocation of PET/MR findings by means of the Dixon MRI sequence was comparable to allocation of PET/CT findings by means of low-dose CT. Quantitative evaluation revealed a high correlation between mean SUVs measured with PET/MR and PET/CT in lesions (ρ = 0.93) and background tissue (ρ = 0.92). CONCLUSION: This study demonstrates, for what is to our knowledge the first time, that integrated whole-body PET/MR is feasible in a clinical setting with high quality and in a short examination time. The reliability of PET/MR was comparable to that of PET/CT in allowing the detection of hypermetabolic lesions suspicious for malignancy in patients with oncologic diagnoses. Despite different attenuation correction approaches, tracer uptake in lesions and background correlated well between PET/MR and PET/CT. The Dixon MRI sequences acquired for attenuation correction were found useful for anatomic allocation of PET findings obtained by PET/MR in the entire body. These encouraging results may form the foundation for future studies aiming to define the added value of PET/MR over PET/CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FDG PET and PET/CT: EANM procedure guidelines for tumour PET imaging: version 1.0
Boellaard, R., O’Doherty, M. J., Weber, W. A., Mottaghy, F. M., Lonsdale, M. N., Stroobants, S. G., Oyen, W. J. G., Kotzerke, J., Hoekstra, O. S., Pruim, J., et al. (2010) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-009-1297-4 · Cited by 1,326
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Self-citationMartinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Self-citationX-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Hofmann, M., Steinke, F., Scheel, V., Charpiat, G., Farquhar, J., Aschoff, P., Brady, M., Schölkopf, B., & Pichler, B. J. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.049353 · Cited by 495
Simultaneous MR/PET Imaging of the Human Brain: Feasibility Study
Schlemmer, H.-P. W., Pichler, B. J., Schmand, M., Burbar, Z., Michel, C., Ladebeck, R., Jattke, K., Townsend, D., Nahmias, C., Jacob, P. K., et al. (2008) · Radiology · doi:10.1148/radiol.2483071927 · Cited by 474
MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
Keereman, V., Fierens, Y., Broux, T., De Deene, Y., Lonneux, M., & Vandenberghe, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.065425 · Cited by 442
Design and performance evaluation of a whole-body Ingenuity TF PET–MRI system
Zaidi, H., Ojha, N., Morich, M., Griesmer, J., Hu, Z., Maniawski, P., Ratib, O., Izquierdo-Garcia, D., Fayad, Z. A., & Shao, L. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/013 · Cited by 402
Performance test of an LSO-APD detector in a 7-T MRI scanner for simultaneous PET/MRI.
Pichler, B. J., Judenhofer, M. S., Catana, C., Walton, J. H., Kneilling, M., Nutt, R. E., Siegel, S. B., Claussen, C. D., & Cherry, S. R. (2006) · PubMed · Cited by 396
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Westerterp, M., Pruim, J., Oyen, W., Hoekstra, O., Paans, A., Visser, E., van Lanschot, J., Sloof, G., & Boellaard, R. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0224-1 · Cited by 294
Automatic, three-segment, MR-based attenuation correction for whole-body PET/MR data
Schulz, V., Torres-Espallardo, I., Renisch, S., Hu, Z., Ojha, N., Börnert, P., Perkuhn, M., Niendorf, T., Schäfer, W. M., Brockmann, H., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1603-1 · Cited by 292
Hybrid PET/MRI of Intracranial Masses: Initial Experiences and Comparison to PET/CT
Boss, A., Bisdas, S., Kolb, A., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.074773 · Cited by 261
Combined PET/MRI: a new dimension in whole-body oncology imaging?
Antoch, G., & Bockisch, A. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0951-6 · Cited by 250
MRI-Assisted PET Motion Correction for Neurologic Studies in an Integrated MR-PET Scanner
Catana, C., Benner, T., van der Kouwe, A., Byars, L., Hamm, M., Chonde, D. B., Michel, C. J., El Fakhri, G., Schmand, M., & Sorensen, A. G. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079343 · Cited by 181
Simultaneous Reconstruction of Activity and Attenuation for PET/MR
Salomon, A., Goedicke, A., Schweizer, B., Aach, T., & Schulz, V. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2095464 · Cited by 174
Eiber, M., Martinez-Möller, A., Souvatzoglou, M., Holzapfel, K., Pickhard, A., Löffelbein, D., Santi, I., Rummeny, E. J., Ziegler, S., Schwaiger, M., et al. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1842-9 · Cited by 173
Self-citationZiegler, S. I., Pichler, B. J., Boening, G., Rafecas, M., Pimpl, W., Eckart Lorenz, G., Schmitz, N., & Schwaiger, M. (2001) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000438 · Cited by 165
Self-citationHigh resolution BrainPET combined with simultaneous MRI
Langen, K., Weirich, C., Kops, E. R., Kaffanke, J. B., Tellmann, L., Scheins, J. J., Neuner, I., Stoffels, G., Fischer, K., Caldeira, L., et al. (2011) · Nuklearmedizin - NuclearMedicine · doi:10.3413/nukmed-0347-10-09 · Cited by 145
Scheuermann, J. S., Saffer, J. R., Karp, J. S., Levering, A., & Siegel, B. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057455 · Cited by 126
A look ahead: PET/MR versus PET/CT
von Schulthess, G. K., & Schlemmer, H.-P. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0940-9 · Cited by 120
Evaluation of the attenuation properties of MR equipment for its use in a whole-body PET/MR scanner
Delso, G., Martínez-Möller, A., Bundschuh, R. A., Ladebeck, R., Candidus, Y., Faul, D. D., & Ziegler, S. I. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/011 · Cited by 118
Self-citationSoftware approach to merging molecular with anatomic information.
Slomka, P. J. (2004) · PubMed · Cited by 118
Jakoby, B., Bercier, Y., Watson, C. C., Bendriem, B., & Townsend, D. W. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2009.2015764 · Cited by 110
The effect of limited MR field of view in MR/PET attenuation correction
Delso, G., Martínez-Möller, A., Bundschuh, R. A., Nekolla, S. G., & Ziegler, S. I. (2010) · Medical Physics · doi:10.1118/1.3431576 · Cited by 102
Self-citationMR-based attenuation correction for torso-PET/MR imaging: pitfalls in mapping MR to CT data
Beyer, T., Weigert, M., Quick, H. H., Pietrzyk, U., VOGT, F. M., Palm, C., Antoch, G., Müller, S. P., & Bockisch, A. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0734-0 · Cited by 102
Pfannenberg, A. C., Aschoff, P., Brechtel, K., Müller, M., Bares, R., Paulsen, F., Scheiderbauer, J., Friedel, G., Claussen, C. D., & Eschmann, S. M. (2006) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0186-3 · Cited by 97
Schöder, H. M., Erdi, Y. E., Chao, K., Gönen, M., Larson, S. M., & YEUNG, H. W. D. (2004) · PubMed · Cited by 85
Is MR-guided Attenuation Correction a Viable Option for Dual-Modality PET/MR Imaging?
Zaidi, H. (2007) · Radiology · doi:10.1148/radiol.2443070092 · Cited by 80
PET-MRI Fusion in Head-and-Neck Oncology: Current Status and Implications for Hybrid PET/MRI
Loeffelbein, D. J., Souvatzoglou, M., Wankerl, V., Martínez-Möller, A., Dinges, J., Schwaiger, M., & Beer, A. J. (2011) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.joms.2011.02.120 · Cited by 80
Self-citationAn integrated MR/PET system: prospective applications
Schlemmer, H.-P., Pichler, B. J., Krieg, R., & Heiss, W. (2008) · Abdominal Imaging · doi:10.1007/s00261-008-9450-2 · Cited by 74
Basu, S. K., Kung, J. W., Houseni, M., ZHUANG, H., Tidmarsh, G. F., & Alavi, A. A. (2009) · PubMed · Cited by 65
The Clinical Role of Fusion Imaging Using PET, CT, and MR Imaging
Zaidi, H., Montandon, M., & Alavi, A. A. (2009) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2009.09.010 · Cited by 57
Narrow time-window dual-point 18F-FDG PET for the diagnosis of thoracic malignancy
Conrad, G. R., & Sinha, P. (2003) · Nuclear Medicine Communications · doi:10.1097/00006231-200311000-00002 · Cited by 52
Three-region MRI-based whole-body attenuation correction for automated PET reconstruction
Steinberg, J. D., Jia, G., Sammet, S., Zhang, J., Hall, N. C., & Knopp, M. V. (2009) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2009.11.002 · Cited by 38
Optimizing Imaging Time for Improved Performance in Oncology PET Studies
Thie, J. A. (2002) · Molecular Imaging and Biology · doi:10.1016/s1095-0397(01)00061-9 · Cited by 38
The effect of inaccurate bone attenuation coefficient and segmentation on reconstructed PET images
Schleyer, P. J., Schaeffter, T., & Marsden, P. K. (2010) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e32833b0573 · Cited by 28
Update of PET and PET/CT for hepatobiliary and pancreatic malignancies
Delbeke, D., & Martin, W. H. (2005) · HPB · doi:10.1080/13651820510028909 · Cited by 25
Completion of a truncated attenuation image from the attenuated PET emission data
Nuyts, J. L., Michel, C. J., Fenchel, M., Bal, G., & Watson, C. (2010) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2010.5874154 · Cited by 18
Thomas, A. J., DaSilva, J. N., Lortie, M., Renaud, J. M., Kenk, M., Beanlands, R. S., & deKemp, R. A. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082701 · Cited by 16
Cited by
Simultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate Cancer
Eiber, M., Weirich, G., Holzapfel, K., Souvatzoglou, M., Haller, B., Rauscher, I., Beer, A. J., Wester, H.-J., Gschwend, J., Schwaiger, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.12.053 · Cited by 568
Self-citationMATR: Multimodal Medical Image Fusion via Multiscale Adaptive Transformer
Tang, W., He, F., Liu, Y., & Duan, Y. (2022) · IEEE Transactions on Image Processing · doi:10.1109/tip.2022.3193288 · Cited by 442
Positron Emission Tomography (PET) in Oncology
Gallamini, A., Zwarthoed, C., & Borra, A. (2014) · Cancers · doi:10.3390/cancers6041821 · Cited by 312
PET/MRI for Neurologic Applications
Catana, C., Drzezga, A., Heiss, W.-D., & Rosen, B. R. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.105346 · Cited by 288
Self-citationSchäfer, J. F., Gatidis, S., Schmidt, H., Gückel, B., Bezrukov, I., Pfannenberg, C. A., Reimold, M., Ebinger, M., Fuchs, J., Claussen, C. D., et al. (2014) · Radiology · doi:10.1148/radiol.14131732 · Cited by 215
Metadata
- Authors
- Drzezga, A., Souvatzoglou, M., Eiber, M., Beer, A. J., Fürst, S., Martinez-Möller, A., Nekolla, S. G., Ziegler, S., Ganter, C., Rummeny, E. J., & Schwaiger, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-04-25
- Volume
- 53
- Issue
- 6
- Pages
- 845-855
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2140479375
- Cited by
- 508
- References
- 41
- FWCI
- 52.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.