NEMA NU 4-2008 Comparison of Preclinical PET Imaging Systems
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The National Electrical Manufacturers Association (NEMA) standard NU 4-2008 for performance measurements of small-animal tomographs was recently published. Before this standard, there were no standard testing procedures for preclinical PET systems, and manufacturers could not provide clear specifications similar to those available for clinical systems under NEMA NU 2-1994 and 2-2001. Consequently, performance evaluation papers used methods that were modified ad hoc from the clinical PET NEMA standard, thus making comparisons between systems difficult. METHODS: We acquired NEMA NU 4-2008 performance data for a collection of commercial animal PET systems manufactured since 2000: microPET P4, microPET R4, microPET Focus 120, microPET Focus 220, Inveon, ClearPET, Mosaic HP, Argus (formerly eXplore Vista), VrPET, LabPET 8, and LabPET 12. The data included spatial resolution, counting-rate performance, scatter fraction, sensitivity, and image quality and were acquired using settings for routine PET. RESULTS: The data showed a steady improvement in system performance for newer systems as compared with first-generation systems, with notable improvements in spatial resolution and sensitivity. CONCLUSION: Variation in system design makes direct comparisons between systems from different vendors difficult. When considering the results from NEMA testing, one must also consider the suitability of the PET system for the specific imaging task at hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National electrical manufacturers association
(1926) · Journal of the A.I.E.E. · doi:10.1109/jaiee.1926.6537344 · Cited by 860
MicroPET: a high resolution PET scanner for imaging small animals
Cherry, S. R., Shao, Y., Silverman, R. W., Meadors, K., Siegel, S., Chatziioannou, A., Young, J. W., Jones, W., Moyers, J. C., Newport, D., et al. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.596981 · Cited by 609
Self-citation2000 IEEE Nuclear Science Symposium Conference Record
(2000) · 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149) · doi:10.1109/nssmic.2000.949858 · Cited by 496
(2005) · PubMed · Cited by 395
Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.
Wang, Y., Seidel, J., Tsui, B. M. W., Vaquero, J. J., & Pomper, M. G. (2006) · PubMed · Cited by 329
Self-citationPerformance evaluation of the microPET P4: a PET system dedicated to animal imaging
Tai, Y. C., Chatziioannou, A., Siegel, S., Young, J., Newport, D., Goble, R. N., Nutt, R. E., & Cherry, S. R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/7/308 · Cited by 308
Self-citationBao, Q., Newport, D., Chen, M., Stout, D. B., & Chatziioannou, A. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056374 · Cited by 306
Self-citationA 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals
Jeavons, A. P., Chandler, R. A., & Dettmar, C. A. R. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775564 · Cited by 259
Performance evaluation of the microPET R4 PET scanner for rodents
Knoess, C., Siegel, S., Smith, A., Newport, D., Richerzhagen, N., Winkeler, A., Jacobs, A., Goble, R. N., Graf, R., Wienhard, K., et al. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1052-6 · Cited by 256
A high resolution animal PET scanner using compact PS-PMT detectors
Watanabe, M., Okada, H., Shimizu, K., Omura, T., Yoshikawa, E., Kosugi, T., Mori, S., & Yamashita, T. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.597001 · Cited by 241
Performance Measurement of the microPET Focus 120 Scanner
Kim, J. S., Lee, J. S., Im, K. C., Kim, S. J., Kim, S.-Y., Lee, D. S., & Moon, D. H. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.040550 · Cited by 180
The design and physical characteristics of a small animal positron emission tomograph
Bloomfield, P. M., Rajeswaran, S., Spinks, T. J., Hume, S. P., Myers, R., Ashworth, S., Clifford, K. M., Jones, W. F., Byars, L. G., Young, J., et al. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/6/010 · Cited by 164
Performance Evaluation of the LabPET APD-Based Digital PET Scanner
Bergeron, M., Cadorette, J., Beaudoin, J.-F., Lepage, M. D., Robert, G., Selivanov, V. V., Tétrault, M., Viscogliosi, N., Norenberg, J. P., Fontaine, R., et al. (2009) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2008.2010257 · Cited by 155
Self-citationImaging performance of a-PET: a small animal PET camera
Surti, S., Karp, J. S., Perkins, A. E., Cardi, C. A., Daube-Witherspoon, M. E., Kuhn, A., & Muehllehner, G. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.844078 · Cited by 98
Self-citationPerformance Evaluation of the microPET®—FOCUS-F120
Laforest, R., Longford, D., Siegel, S., Newport, D. F., & Yap, J. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.889312 · Cited by 93
Self-citationPerformance evaluation of the LabPET™ APD-based digital PET scanner
Bergeron, M., Cadorette, J., Beaudoin, J.-F., Rousseau, J. A., Dumoulin, M., Lepage, M. D., Robert, G., Selivanov, V. V., Tétrault, M., Viscogliosi, N., et al. (2007) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2007.4437041 · Cited by 57
Self-citationDesign and performance evaluation of a coplanar multimodality scanner for rodent imaging
Lage, E., Vaquero, J. J., Sisniega, A., España, S., Tapias, G., Abella, M., Rodriguez-Ruano, A., Ortuño, J. E., Udías, Á., & Desco, M. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/18/005 · Cited by 48
Self-citationPerformance evaluation of the LabPET12, a large axial FOV APD-based digital PET scanner
Bergeron, M., Cadorette, J., Bureau-Oxton, C., Beaudoin, J.-F., Tétrault, M., Leroux, J., Lepage, M. D., Robert, G., Fontaine, R., & Lecomte, R. (2009) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2009.5401915 · Cited by 19
Self-citation
Cited by
Krishnamoorthy, S., Blankemeyer, E., Mollet, P., Surti, S., Van Holen, R., & Karp, J. S. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aacec3 · Cited by 141
“This combination results in excellent sensitivity - amongst the highest from commercial manufacturers of small animal PET (Goertzen et al., 2012, Sato et al., 2016).”
BackgroundSelf-citation
Metadata
- Authors
- Goertzen, A. L., Bao, Q., Bergeron, M., Blankemeyer, E., Blinder, S., Cañadas, M., Chatziioannou, A. F., Dinelle, K., Elhami, E., Jans, H.-S., Lage, E., Lecomte, R., Sossi, V., Surti, S., Tai, Y.-C., Vaquero, J. J., Vicente, E., Williams, D. A., & Laforest, R.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-06-14
- Volume
- 53
- Issue
- 8
- Pages
- 1300-1309
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2144240099
- Cited by
- 237
- References
- 18
- FWCI
- 13.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.