Noise Considerations for PET Quantification Using Maximum and Peak Standardized Uptake Value
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
UNLABELLED: In tumor response monitoring studies with (18)F-FDG PET, maximum standardized uptake value (SUV(max)) is commonly applied as a quantitative metric. Although it has several advantages due to its simplicity of determination, concerns about the influence of image noise on single-pixel SUV(max) persist. In this study, we measured aspects of bias and reproducibility associated with SUV(max) and the closely related peak SUV (SUV(peak)) using real patient data to provide a realistic noise context. METHODS: List-mode 3-dimensional PET data were acquired for 15 min over a single bed position in twenty (18)F-FDG oncology patients. For each patient, data were sorted so as to form 2 sets of images: respiration-gated images such that each image had statistical quality comparable to a 3 min/bed position scan, and 5 statistically independent (ungated) images of different durations (1, 2, 3, 4, and 5 min). Tumor SUV(max) and SUV(peak) (12-mm-diameter spheric region of interest positioned so as to maximize the enclosed average) were analyzed in terms of reproducibility and bias. The component of reproducibility due to statistical noise (independent of physiologic and other variables) was measured using paired SUVs from 2 comparable respiration-gated images. Bias was measured as a function of scan duration. RESULTS: Replicate tumor SUV measurements had a within-patient SD of 5.6% ± 0.9% for SUV(max) and 2.5% ± 0.4% for SUV(peak). SUV(max) had average positive biases of 30%, 18%, 12%, 4%, and 5% for the 1-, 2-, 3-, 4-, and 5-min images, respectively. SUV(peak) was also biased but to a lesser extent: 11%, 8%, 5%, 1%, and 4% for the 1-, 2-, 3-, 4-, and 5-min images, respectively. CONCLUSION: The advantages of SUV(max) are best exploited when PET images have a high statistical quality. For images with noise properties typically associated with clinical whole-body studies, SUV(peak) provides a slightly more robust alternative for assessing the most metabolically active region of tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · cited 1×
“For each of these 4 reconstruction and analysis conditions, the difference between corresponding SUVmeasurements was recorded for each patient and reproducibility was assessed using the Bland– Altman approach (31).”
MethodMeasuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 1×
“PET images were reconstructed according to our current clinical oncology protocol, which involves 3-dimensional ordered-subset expectation maximization, 2 iterations, 21 subsets, a gaussian filter of 3 mm in full width at half maximum, model-based scatter correction (25), and CT-based attenuation correction (26).”
MethodA Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662 · cited 1×
“SUVs have been used in PET for more than 20 y (5), but although significant efforts have been made to ensure more consistent patient preparation and data acquisition (6,7), there remain some differences in the practical implementation of the technique (8).”
MethodInstrumentation factors affecting variance and bias of quantifying tracer uptake with PET/CT
Doot, R. K., Scheuermann, J. S., Christian, P. E., Karp, J. S., & Kinahan, P. E. (2010) · Medical Physics · doi:10.1118/1.3499298 · Cited by 82 · cited 2×
“Some investigators have found that the reproducibility of SUVmax was broadly similar to SUV metrics based on larger ROIs (22) or that reproducibility of SUVmax was only modestly worse (23).”
Background
Cited by
Practical PERCIST: A Simplified Guide to PET Response Criteria in Solid Tumors 1.0
O, J. H., Lodge, M. A., & Wahl, R. L. (2016) · Radiology · doi:10.1148/radiol.2016142043 · Cited by 521
Self-citationA review on segmentation of positron emission tomography images
Foster, B., Bagci, U., Mansoor, A., Xu, Z., & Mollura, D. J. (2014) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2014.04.014 · Cited by 370
Repeatability of SUV in Oncologic 18F-FDG PET
Lodge, M. A. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.186353 · Cited by 214
Self-citationFeasibility of state of the art PET/CT systems performance harmonisation
Kaalep, A., Sera, T., Rijnsdorp, S., Yaqub, M., Talsma, A., Lodge, M. A., & Boellaard, R. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-3977-4 · Cited by 160
Self-citationSher, A., Lacoeuille, F., Fosse, P., Vervueren, L., Cahouet-Vannier, A., Dabli, D., Bouchet, F., & Couturier, O. (2016) · EJNMMI Research · doi:10.1186/s13550-016-0177-8 · Cited by 111
Quak, E., Le Roux, P.-Y., Hofman, M. S., Robin, P., Bourhis, D., Callahan, J., Binns, D., Desmonts, C., Salaun, P.-Y., Hicks, R. J., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3128-0 · Cited by 107
“No explanation was found for the higher ratios in overweight patients as compared to normal weight patients, a finding in disagreement with studies showing that SUVpeak is less sensitive than SUVmax to image noise [21].”
ResultAlberts, I., Sachpekidis, C., Prenosil, G., Viscione, M., Bohn, K. P., Mingels, C., Shi, K., Ashar-Oromieh, A., & Rominger, A. (2021) · Annals of Nuclear Medicine · doi:10.1007/s12149-021-01588-6 · Cited by 70
Kramer, G. M., Frings, V., Hoetjes, N., Hoekstra, O. S., Smit, E. F., de Langen, A. J., & Boellaard, R. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.170225 · Cited by 65
Reproducibility and uptake time dependency of volume-based parameters on FDG-PET for lung cancer
Kitao, T., Hirata, K., Shima, K., Hayashi, T., Sekizawa, M., Takei, T., Ichimura, W., Harada, M., Kondo, K., & Tamaki, N. (2016) · BMC Cancer · doi:10.1186/s12885-016-2624-3 · Cited by 32
FDG PET/CT of the non-malignant liver in an increasingly obese world population
Keramida, G., & Peters, A. M. (2020) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12651 · Cited by 25
Bahce, I., Vos, C. G., Dickhoff, C., Hartemink, K. J., Dahele, M., Smit, E. F., Boellaard, R., Hoekstra, O. S., & Thunnissen, E. (2014) · Lung Cancer · doi:10.1016/j.lungcan.2014.04.010 · Cited by 25
Metadata
- Authors
- Lodge, M. A., Chaudhry, M. A., & Wahl, R. L.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2012-05-24
- Volume
- 53
- Issue
- 7
- Pages
- 1041-1047
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W1968597302
- Cited by
- 226
- References
- 5
- FWCI
- 9.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.