The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Hybrid PET/MR Imaging of the Heart: Potential, Initial Experiences, and Future Prospects
Open accessAbstract
PET/CT and other combined scanners have in the past decade rapidly emerged as important research tools and are proving to be invaluable for improved diagnostics in routine nuclear medicine. The design of hybrid PET/MR scanners presented a formidable technical challenge, and only recently were these instruments introduced to the market. Initial expectations of the performance of these scanners have been high, notably because of the potential for superior tissue contrast inherent in the MR modality, as well as the potential for multiparametric functional imaging in conjunction with PET. However, the additional value and potential clinical role that these new systems might bring to the cardiac field have yet to be documented. This review presents a comparative summary of the existing applications for PET and MR in the field of cardiology and suggests potential cardiac applications exploiting unique properties of the newly introduced combined instrumentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Annexins: From Structure to Function
Gerke, V., & Moss, S. E. (2002) · Physiological Reviews · doi:10.1152/physrev.00030.2001 · Cited by 2,029
ACC/AHA/ASNC Guidelines for the Clinical Use of Cardiac Radionuclide Imaging—Executive Summary
Klocke, F. J., Baird, M. G., Lorell, B. H., Bateman, T. M., Messer, J. V., Berman, D. S., O’Gara, P. T., Carabello, B. A., Russell, R. O., Cerqueira, M. D., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.011 · Cited by 1,303
Kim, W. Y., Stuber, M., Börnert, P., Kissinger, K. V., Manning, W. J., & Botnar, R. M. (2002) · Circulation · doi:10.1161/01.cir.0000025629.85631.1e · Cited by 302
Samarin, A., Burger, C., Wollenweber, S. D., Crook, D. W., Burger, I. A., Schmid, D. T., von Schulthess, G. K., & Kuhn, F. P. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2113-0 · Cited by 251
Cited by
Myocardial Fibrosis: Biomedical Research from Bench to Bedside
Gyöngyösi, M., Winkler, J., Ramos, I., Do, Q.-T., Firat, H., McDonald, K., González, A., Thum, T., Díez, J., Jaisser, F., et al. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.696 · Cited by 397
Bloom, M. W., Hamo, C. E., Cardinale, D., Ky, B., Nohria, A., Baer, L., Skopicki, H., Lenihan, D. J., Gheorghiade, M., Lyon, A. R., et al. (2016) · Circulation: Heart Failure · doi:10.1161/circheartfailure.115.002661 · Cited by 334
on behalf of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM), Bucerius, J., Hyafil, F., Verberne, H. J., Slart, R. H. J. A., Lindner, O., Sciagra, R., Agostini, D., Übleis, C., Gimelli, A., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3259-3 · Cited by 257
Metadata
- Authors
- Rischpler, C., Nekolla, S. G., Dregely, I., & Schwaiger, M.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2013-02-12
- Volume
- 54
- Issue
- 3
- Pages
- 402-415
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2151065218
- Cited by
- 167
- References
- 4
- FWCI
- 19.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hybrid PET/MR Imaging of the Heart: Potential, Initial Experiences, and Future Prospects. https://app.cochat.ai/papers/10.2967/jnumed.112.105353
- The paper
- Rischpler, C., Nekolla, S. G., Dregely, I., & Schwaiger, M. (2013). Hybrid PET/MR Imaging of the Heart: Potential, Initial Experiences, and Future Prospects. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.112.105353
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.