CoChat

MIRD Pamphlet No. 24: Guidelines for Quantitative 131I SPECT in Dosimetry Applications

Open access
Dewaraja, Yuni K., Ljungberg, Michael, Green, Alan J., Zanzonico, Pat B., Frey, Eric C., SNMMI MIRD Committee, Bolch, Wesley E., Brill, A. Bertrand, Dunphy, Mark, Fisher, Darrell R., Howell, Roger W., Meredith, Ruby F., Sgouros, George, Wessels, Barry W. · 2013 · Journal of Nuclear Medicine
Cited by 336

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

The reliability of radiation dose estimates in internal radionuclide therapy is directly related to the accuracy of activity estimates obtained at each imaging time point. The recently published MIRD pamphlet no. 23 provided a general overview of quantitative SPECT imaging for dosimetry. The present document is the first in a series of isotope-specific guidelines that will follow MIRD 23 and focuses on one of the most commonly used therapeutic radionuclides, (131)I. The purpose of this document is to provide guidance on the development of protocols for quantitative (131)I SPECT in radionuclide therapy applications that require regional (normal organs, lesions) and 3-dimensional dosimetry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.113.122390

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Dewaraja, Y. K., Ljungberg, M., Green, A. J., Zanzonico, P. B., Frey, E. C., SNMMI MIRD Committee, Bolch, W. E., Brill, A. B., Dunphy, M., Fisher, D. R., Howell, R. W., Meredith, R. F., Sgouros, G., & Wessels, B. W.
Venue
Journal of Nuclear Medicine
Published
2013-10-15
Volume
54
Issue
12
Pages
2182-2188
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2166990279
Cited by
336
References
13
FWCI
36.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.