Radionuclides in Nephrourology, Part 1: Radiopharmaceuticals, Quality Control, and Quantitative Indices
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Radionuclide renal scintigraphy provides important functional data to assist in the diagnosis and management of patients with a variety of suspected genitourinary tract problems, but the procedures are underutilized. Maximizing the utility of the available studies (as well as the perception of utility by referring physicians) requires a clear understanding of the clinical question, attention to quality control, acquisition of the essential elements necessary to produce an informed interpretation, and production of a report that presents a coherent impression that specifically addresses the clinical question and is supported by data contained in the report. To help achieve these goals, part 1 of this review covers information that should be provided to the patient before the scan, describes the advantages and limitations of the available radiopharmaceuticals, discusses quality control elements needed to optimize the study, summarizes approaches to the measurements of renal function, and focuses on recommended quantitative indices and their diagnostic applications. Although the primary focus is the adult patient, aspects of the review also apply to the pediatric population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levey, A. S., Bosch, J. P., Lewis, J. B., Greene, T., Rogers, N., Roth, D., & for the Modification of Diet in Renal Disease Study Group* (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-6-199903160-00002 · Cited by 15,079 · cited 1×
“The initial evaluation of renal function can be improved using the 4-variable, Modification of Diet in Renal Disease study equation (56).”
MethodLevey, A. S., Coresh, J., Bolton, K., Culleton, B. F., Harvey, K. S., Ikizler, T. A., Johnson, C. A., Kausz, A., Kimmel, P. L., Kusek, J. W., et al. (2002) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 11,633
Goodpasture syndrome during the course of a Schönlein-Henoch purpura
Carreras, L., Poveda, R., Bas, J., Mestre, M., Rama, I., & Carrera, M. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32799 · Cited by 1,474
Froissart, M., Rossert, J., Jacquot, C., Paillard, M., & Houillier, P. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2004070549 · Cited by 803
Report of the Radionuclides in Nephrourology Committee on Renal Clearance
Blaufox, M. D., Aurell, M., Bubeck, B., Fommei, E., PIEPSZ, A., Russell, C., Taylor, A. T., Thomsen, H. S., & Volterrani, D. (1998) · The Journal of Urology · doi:10.1097/00005392-199812010-00116 · Cited by 311
Self-citationSelection of Routine Method for Determination of Glomerular Filtration Rate in Adult Patients
Bröchner-Mortensen, J., & Rödbro, P. (1976) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365517609068016 · Cited by 273 · cited 1×
“Measurement of creatinine clearance using a 24-h urine collection is cumbersome, inconvenient, and often unreliable; moreover, repeated measurements in stable patients have shown a disappointingly high 25% coefficient of variation (SD/mean) (54,55).”
MethodGATES, G. F. (1983) · Clinical Nuclear Medicine · doi:10.1097/00003072-198309000-00003 · Cited by 194
Monitoring Renal Function and Limitations of Renal Function Tests
Prigent, A. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.09.003 · Cited by 170
Uchino, H., Tamai, I., Yamashita, K., Minemoto, Y., Sai, Y., Yabuuchi, H., Miyamoto, K., Takeda, E., & Tsuji, A. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.2407 · Cited by 148 · cited 1×
“99mTcMAG3 accumulates in the proximal tubular cell and is then transported into the tubular lumen via organic anion transporters on the apical membrane (9); if the apical membrane transporter is impaired to a greater extent than the basolateral transporter, 99mTcMAG3 can be extracted from the plasma with greater effic…”
BackgroundPharmacokinetics of technetium-99m-MAG3 in humans.
Bubeck, B., Brandau, W., Weber, E., Kälble, T., Parekh, N., & Georgi, P. (1990) · PubMed · Cited by 118
Assessment of Glomerular Filtration Rate Measurement with Plasma Sampling: A Technical Review
Murray, A. W., Barnfield, M. C., Waller, M. L., Telford, T., & Peters, A. M. (2013) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.113.121004 · Cited by 65 · cited 3×
“These techniques generally provide reliable results, can be performed at the time of a standard renal scan using 99mTc-MAG3 or 99mTc-DTPA, and allow chemotherapy to be optimized to an individual patient’s underlying renal function (62).”
BackgroundTransport of 99mTc-MAG3 via rat renal organic anion transporter 1.
Shikano, N., Kanai, Y., Kawai, K., Ishikawa, N., & Endou, H. (2004) · PubMed · Cited by 50
Bao, J., Manatunga, A. K., Binongo, J., & Taylor, A. T. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.10.5909 · Cited by 29
Self-citationHALKAR, R. K., Taylor, A. T., Manatunga, A. K., Issa, M. M., Myrick, S. E., Grant, S. F., & Shenvi, N. V. (2007) · Urology · doi:10.1016/j.urology.2006.11.026 · Cited by 15 · cited 1×
“Camera-based clearances appear to be reproducible and are superior to creatinine clearance for monitoring changes in renal function (68).”
BackgroundSelf-citationRadiopharmaceuticals for Renal Positron Emission Tomography Imaging
Szabó, Z. R., Xia, J., & Mathews, W. B. (2007) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2007.09.008 · Cited by 12 · cited 1×
“functional renal imaging; others are under development, but they are currently limited to research applications and were discussed in a previous review (29).”
BackgroundReference Values for Renal Size Obtained From MAG3 Scintigraphy
Taylor, A. T., Shenvi, N. V., Folks, R. D., et al. (2012) · Clinical Nuclear Medicine · doi:10.1097/rlu.0b013e318270866f · Cited by 8 · cited 1×
“Regression equations to define the upper and lower limits of renal size normalized for body surface area have recently been developed for adults (47).”
BackgroundSelf-citation
Cited by
Transport and interactions of nanoparticles in the kidneys
Du, B., Yu, M., & Zheng, J. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0038-3 · Cited by 649
Noninvasive Staging of Kidney Dysfunction Enabled by Renal‐Clearable Luminescent Gold Nanoparticles
Yu, M., Zhou, J., Du, B., Ning, X., Authement, C., Gandee, L., Kapur, P., Hsieh, J., & Zheng, J. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511148 · Cited by 174
Calabria, F., Leporace, M., Tavolaro, R., & Bagnato, A. (2023) · Radiology‐Nuclear Medicine Diagnostic Imaging · doi:10.1002/9781119603627.ch4 · Cited by 3
Metadata
- Authors
- Taylor, A. T.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2014-02-18
- Volume
- 55
- Issue
- 4
- Pages
- 608-615
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2155698107
- Cited by
- 162
- References
- 16
- FWCI
- 8.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.