CoChat

Characterization of 3 PET Tracers for Quantification of Mitochondrial and Synaptic Function in Healthy Human Brain: 18F-BCPP-EF, 11C-SA-4503, and 11C-UCB-J

Mansur, Ayla, Rabiner, Eugenii A., Comley, Robert A., Lewis, Yvonne, Middleton, Lefkos T., Huiban, Mickael, Passchier, Jan, Tsukada, Hideo, Gunn, Roger N. · 2020 · Journal of Nuclear Medicine
Cited by 84

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Mitochondrial complex 1 is involved in maintaining brain bioenergetics; σ-1 receptor responds to neuronal stress; and synaptic vesicle protein 2A reflects synaptic integrity. Expression of each of these proteins is altered in neurodegenerative diseases. Here, we characterize the kinetic behavior of 3 PET radioligands—18F-BCPP-EF, 11C-SA-4503, and 11C-UCB-J—for the measurement of mitochondrial complex 1, σ-1 receptor, and synaptic vesicle protein 2A, respectively, and determine appropriate analysis workflows for their application in future studies of the in vivo molecular pathology of these diseases. Methods: Twelve human subjects underwent dynamic PET scans with each radioligand, including associated arterial blood sampling. A range of kinetic models was investigated to identify an optimal kinetic analysis method for each radioligand and a suitable acquisition duration. Results: All 3 radioligands readily entered the brain and yielded heterogeneous uptake consistent with the known distribution of the targets. The optimal models determined for the regional estimates of volume of distribution were multilinear analysis 1 (MA1) and the 2-tissue-compartment model for 18F-BCPP-EF, MA1 for 11C-SA-4503, and both MA1 and the 1-tissue-compartment model for 11C-UCB-J. Acquisition times of 70, 80, and 60 min for 18F-BCPP-EF, 11C-SA-4503, 11C-UCB-J, respectively, provided good estimates of regional volume of distribution values. An effect of age was observed on 18F-BCPP-EF and 11C-UCB-J signal in the caudate. Conclusion: These ligands can be assessed for their potential to stratify patients or monitor the progression of molecular neuropathology in neurodegenerative diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.119.228080

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
Mansur, A., Rabiner, E. A., Comley, R. A., Lewis, Y., Middleton, L. T., Huiban, M., Passchier, J., Tsukada, H., & Gunn, R. N.
Venue
Journal of Nuclear Medicine
Published
2019-07-19
Volume
61
Issue
1
Pages
96-103
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2964032412
Cited by
84
References
10
FWCI
6.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.