CoChat

Simplified Quantification of 11C-UCB-J PET Evaluated in a Large Human Cohort

Open access
Naganawa, Mika, Gallezot, Jean-Dominique, Finnema, Sjoerd J., Matuskey, David, Mecca, Adam, Nabulsi, Nabeel B., Labaree, David, Ropchan, Jim, Malison, Robert T., D’Souza, Deepak Cyril, Esterlis, Irina, Detyniecki, Kamil, van Dyck, Christopher H., Huang, Yiyun, Carson, Richard E. · 2021 · Journal of Nuclear Medicine
Cited by 28

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

11C-UCB-J ((R)-1-((3-(11C-methyl-11C)pyridin-4-yl)methyl)-4-(3,4,5-trifluorophenyl)pyrrolidin-2-one) is a PET tracer for synaptic vesicle glycoprotein 2A, which may be a marker of synaptic density. To simplify the scan protocol, SUV ratios (SUVRs) were compared with model-based nondisplaceable binding potential (BPND) to select the optimal time window in healthy and neuropsychiatric subjects. Methods: In total, 141 scans were acquired for 90 min. Arterial blood sampling and metabolite analysis were conducted. SUVR-1 (centrum semiovale reference region) was computed for six 30-min windows and compared with 1-tissue-compartment model BPND. Simulations were performed to assess the time dependency of SUVR-1. Results: Greater correlation and less bias were observed for SUVR-1 at later time windows for all subjects. Simulations showed that the agreement between SUVR-1 and BPND is time-dependent. Conclusion: The 60- to 90-min period provided the best match between SUVR-1 and BPND (−1% ± 7%); thus, a short scan is sufficient for accurate quantification of 11C-UCB-J–specific binding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.120.243949

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 28

Metadata

Authors
Naganawa, M., Gallezot, J.-D., Finnema, S. J., Matuskey, D., Mecca, A., Nabulsi, N. B., Labaree, D., Ropchan, J., Malison, R. T., D’Souza, D. C., Esterlis, I., Detyniecki, K., van Dyck, C. H., Huang, Y., & Carson, R. E.
Venue
Journal of Nuclear Medicine
Published
2020-07-09
Volume
62
Issue
3
Pages
418-421
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W3041366959
Cited by
28
References
7
FWCI
1.91
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simplified Quantification of 11C-UCB-J PET Evaluated in a Large Human Cohort. https://app.cochat.ai/papers/10.2967/jnumed.120.243949
The paper
Naganawa, M., Gallezot, J.-D., Finnema, S. J., Matuskey, D., Mecca, A., Nabulsi, N. B., Labaree, D., Ropchan, J., Malison, R. T., D’Souza, D. C., Esterlis, I., Detyniecki, K., van Dyck, C. H., Huang, Y., & Carson, R. E. (2021). Simplified Quantification of 11C-UCB-J PET Evaluated in a Large Human Cohort. Journal of Nuclear Medicine. https://doi.org/10.2967/jnumed.120.243949

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.