Histological Reaction to Polyimide Films in the Cochlea
Abstract
The biocompatibility of commercially available polyimides was examined in relation to the sensory and neural structures of the cochlea. Thin films of four different polyimides were prepared as substrates for photolithographically produced scala tympani electrode arrays and implanted in 32 cat cochleae. Following at least three months implantation time, the animals were sacrificed and the cochlea were evaluated histologically for toxicity, differences in the severity of ototoxic effects among the four polyimide groups, and relationships among the different kinds of histopathology secondary to implantation. Findings included the following. Inflammatory reaction to the implants, when present, was generally mild and confined to the immediate vicinity of the implant. Additionally, ototoxic effects were essentially the same across the four groups. Finally, a clear interdependence among the different kinds of cochlear damage secondary to implantation was demonstrated.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Polyimide-based neural implants show good biocompatibility with respect to toxicity and biostability when used as cuff and regenerative-type electrodes.
“Polyimide-based neural implants (Stieglitz et al., 2000) showed good biocompatibility (Haggerty and Lusted, 1989; Richardson et al., 1993) with respect to toxicity as well as biostability (Navarro et al., 1998; Rodrı ´guez et al., 2000) when used as cuff and regenerative-type electrodes.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Haggerty and Lusted, 1989
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U. (2000) · Biomedical Microdevices · doi:10.1023/a:1009955222114 · Cited by 343 · see citing works
Polyimides as biomaterials: preliminary biocompatibility testing
Richardson, R. R., Miller, J. A., & Reichert, W. M. (1993) · Biomaterials · doi:10.1016/0142-9612(93)90183-3 · Cited by 302 · see citing works
Martins, N. R. B., Angelica, A., Chakravarthy, K., Svidinenko, Y., Boehm, F. J., Opris, I., Lebedev, M. A., Swan, M., Garan, S. A., Rosenfeld, J. V., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00112 · Cited by 91 · see citing works
Flexible miniature ribbon cables for long‐term connection to implantable sensors
Hetke, J. F., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators A: Physical · doi:10.1016/0924-4247(90)87076-u · Cited by 33 · see citing works
- Authors
- Haggerty, H. S., & Lusted, H. S.
- Affiliations
- Stanford Medicine (US)
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 1989-01
- Volume
- 107
- Issue
- 1-2
- Pages
- 13-22
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W1978215662
- Cited by
- 31
- References
- 0
- Citations by year
- 2026: 1 · 2024: 1 · 2019: 2 · 2018: 1 · 2013: 1
- FWCI
- 0.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Acta Oto-Laryngologica (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- National Institute of Neurological Disorders and Stroke (N01-NS32352)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Hearing Loss and Rehabilitation
- Life Sciences › Neuroscience › Sensory Systems › Hearing, Cochlea, Tinnitus, Genetics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Keywords
- polyimide films, cochlear implants, biocompatibility, ototoxicity, histopathology, inflammation, auditory nerve, cat cochlea
- MeSH terms
- Animals, Cats, Cochlea, Cochlear Implants, Materials Testing, Resins, Synthetic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review