Cited by 343Neuroscience and Neural EngineeringAnalog and Mixed-Signal Circuit DesignAdvanced MEMS and NEMS Technologies

Micromachined, Polyimide-Based Devices for Flexible Neural Interfaces

Stieglitz, Thomas, Beutel, Hansjo¨rg, Schuettler, Martin, Meyer, J.-Uwe·2000·Biomedical Microdevices

Integrity signals

Registry

Crossref · 10.1023/a:1009955222114

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The reduced size and thickness of recent polymer cuffs opens the possibility of implanting several small cuffs around different fascicles or branches of nerves and achieving selective functional stimulation of a higher number of muscles.

    “The reduced size and thickness of recent polymer cuffs (Stieglitz et al., 2000) also opens the possibility of implantation of several small cuffs around different fascicles or branches of nerves and, consequently, the achievement of selective functional stimulation of a higher number of muscles (Rodrı ´guez et al., 2000; Stieglitz et al., 2003) .”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Stieglitz, T., Beutel, H., Schuettler, M., & Meyer, J.-U.
Affiliations
Fraunhofer Institute for Biomedical Engineering (DE)
Venue
Biomedical Microdevices
Published
2000-12
Volume
2
Issue
4
Pages
283-294
ISSN
  • 1387-2176 (ISSN-L)
  • 1572-8781
OpenAlex
W2204802825
Cited by
343
References
19
Citations by year
2026: 12 · 2025: 13 · 2024: 9 · 2023: 10 · 2022: 5 · 2021: 19 · 2020: 9 · 2019: 18 · 2018: 14 · 2017: 18 · 2016: 20 · 2015: 20 · 2014: 16 · 2013: 18 · 2012: 15
FWCI
1.85
Type
journal article
Language
en
Open access
closed
Locations
  • Biomedical Microdevices (publishedVersion)
  • Publikationsdatenbank der Fraunhofer-Gesellschaft (Fraunhofer-Gesellschaft) (submittedVersion)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
Keywords
flexible neural interfaces, micromachining, neural prosthesis, microelectrode arrays, hybrid integration, retinal prosthesis, implantable electronics, nerve regeneration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review