Simulation techniques in hyperthermia treatment planning
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Abstract Clinical trials have shown that hyperthermia (HT), i.e. an increase of tissue temperature to 39-44 °C, significantly enhance radiotherapy and chemotherapy effectiveness [1]. Driven by the developments in computational techniques and computing power, personalised hyperthermia treatment planning (HTP) has matured and has become a powerful tool for optimising treatment quality. Electromagnetic, ultrasound, and thermal simulations using realistic clinical set-ups are now being performed to achieve patient-specific treatment optimisation. In addition, extensive studies aimed to properly implement novel HT tools and techniques, and to assess the quality of HT, are becoming more common. In this paper, we review the simulation tools and techniques developed for clinical hyperthermia, and evaluate their current status on the path from 'model' to 'clinic'. In addition, we illustrate the major techniques employed for validation and optimisation. HTP has become an essential tool for improvement, control, and assessment of HT treatment quality. As such, it plays a pivotal role in the quest to establish HT as an efficacious addition to multi-modality treatment of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270 · cited 1×
“For dielectric properties, variations of 30% or more have been measured in post-mortem humans [18,19], and even greater variations were shown in breast [20,21] and brain, by means of MR measurements [22].”
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.1.5 · Cited by 3,982 · cited 10×
“Another example of an amended PBHE model is the use of mixed models that incorporate effective conductivity [2,132].”
InfluentialThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156 · cited 1×
“For dielectric properties, variations of 30% or more have been measured in post-mortem humans [18,19], and even greater variations were shown in breast [20,21] and brain, by means of MR measurements [22].”
Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers
Jensen, J. A., & Svendsen, N. B. (1992) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.139123 · Cited by 2,493 · cited 1×
“Freely available software include Field II (impulse response) [85], the faster Focus (fast near-field method and advanced simulation module (ASM) [86,87] and k-wave (ASM) [88,89].”
k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields
Treeby, B. E., & Cox, B. T. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3360308 · Cited by 2,337 · cited 3×
“Freely available software include Field II (impulse response) [85], the faster Focus (fast near-field method and advanced simulation module (ASM) [86,87] and k-wave (ASM) [88,89].”
Physical properties of tissue : a comprehensive reference book
Duck, F. A. (1990) · Cited by 1,675
Heating the patient: a promising approach?
van der Zee, J. (2002) · Annals of Oncology · doi:10.1093/annonc/mdf280 · Cited by 1,220
High intensity focused ultrasound: Physical principles and devices
ter Haar, >., & Coussios, C. (2007) · International Journal of Hyperthermia · doi:10.1080/02656730601186138 · Cited by 805 · cited 2×
“With this input, the radiation pattern of the transducer array is then optimised, usually with incident field-based simulations to obtain the desired depth, shape, and/or trajectory of heating [76].”
Effect of local hyperthermia on blood flow and microenvironment: a review.
Song, C. W. (1984) · PubMed · Cited by 770
Cited by
Datta, N. R., Ordóñez, S. G., Gaipl, U. S., Paulides, M. M., Crezee, H., Gellermann, J., Marder, D., Puric, E., & Bodis, S. (2015) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2015.05.009 · Cited by 588
Self-citationRossmanna, C., & Haemmerich, D. (2014) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2015012486 · Cited by 370
Srinoi, P., Chen, Y.-T., Vittur, V., Marquez, M. D., & Lee, T. R. (2018) · Applied Sciences · doi:10.3390/app8071106 · Cited by 299
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Self-citationFiber Optic Sensors for Temperature Monitoring during Thermal Treatments: An Overview
Schena, E., Tosi, D., Saccomandi, P., Lewis, E., & Kim, T. (2016) · Sensors · doi:10.3390/s16071144 · Cited by 238
“Furthermore, the efficacy of hyperthermal treatment planning tools in therapy management can be strengthened by feedback in the form of accurately measured tissue temperatures [4].”
Laser Ablation for Cancer: Past, Present and Future
Schena, E., Saccomandi, P., & Fong, Y. (2017) · Journal of Functional Biomaterials · doi:10.3390/jfb8020019 · Cited by 192
“As described in [71], the simulations can be divided in three main steps: (1) the first step is the generation of the patient model.”
BackgroundMagnetic Hyperthermia and Radiation Therapy: Radiobiological Principles and Current Practice †
Spirou, S. V., Basini, M., Lascialfari, A., Sangregorio, C., & Innocenti, C. (2018) · Nanomaterials · doi:10.3390/nano8060401 · Cited by 177
Current state of the art of regional hyperthermia treatment planning: a review
Kok, H., Wust, P., Stauffer, P., Bardati, F., van Rhoon, G., & Crezee, J. (2015) · Radiation Oncology · doi:10.1186/s13014-015-0503-8 · Cited by 165
“Significant progress has been made in the development and application of simulation techniques for HTP [20].”
MethodSelf-citationDatta, N. R., Krishnan, S., Speiser, D. E., Neufeld, E., Kuster, N., Bodis, S., & Hofmann, H. (2016) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2016.09.016 · Cited by 92
Self-citationMulti-disciplinary challenges in tissue modeling for wireless electromagnetic powering: a review
Bocan, K. N., Mickle, M. H., & Sejdic, E. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2748338 · Cited by 41
Metadata
- Authors
- Paulides, M. M., Stauffer, P. R., Neufeld, E., Maccarini, P. F., Kyriakou, A., Canters, R. A. M., Diederich, C. J., Bakker, J. F., & Van Rhoon, G. C.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2013-05-14
- Volume
- 29
- Issue
- 4
- Pages
- 346-357
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2036848332
- Cited by
- 199
- References
- 66
- FWCI
- 10.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.