Blink Rate, Blink Amplitude, and Tear Film Integrity during Dynamic Visual Display Terminal Tasks
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
PURPOSE: The present study aimed at investigating the influence of the level of dynamism of two different visual display terminal tasks on spontaneous eyeblink rate, blink amplitude, and tear film integrity. MATERIAL AND METHODS: A total of 25 healthy, young volunteers participated in the study. Blink rate and blink amplitude were recorded in silent primary gaze conditions and while subjects were playing two computer games of similar cognitive demands but different rate of visual information presentation. For each experimental condition, tear volume was evaluated by measuring meniscus height and with the red phenol thread test. Fluorescein and non-invasive break-up time tests, as well as the observation of interference patterns and the estimation of the dry area extension, were employed to assess tear stability. RESULTS: Statistically significant differences were revealed in blink rate (F = 595.85, p < 0.001) and blink amplitude (χ(2) = 34.00, p < 0.001), with blink rate during fast- and slow-paced game play decreasing to almost 1/3 and 1/2 of baseline levels, respectively, and with a larger percentage of incomplete blinks during dynamic tasks. Fluorescein and non-invasive break-up time tests and dry area extension were able to differentiate between experimental conditions in general (F = 408.42, p < 0.001; F = 163.49, p < 0.001; χ(2) = 20.74, p < 0.001), as well as between fast- and slow-paced games, thus suggesting that tear quality was more affected than tear volume. CONCLUSIONS: Blink rate, blink amplitude, and tear film stability were compromised during the most dynamic visual display terminal task, suggesting a negative influence of not only the cognitive aspects of the task, but also of the rate at which new visual information is presented. Frequent breaks and blinking awareness training are recommended for visual display terminal users requiring prolonged periods of visually demanding dynamic computer play or work.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computer Vision Syndrome: A Review
Blehm, C., Vishnu, S., Khattak, A., Mitra, S., & Yee, R. W. (2005) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2005.02.008 · Cited by 860
The Lack of Association Between Signs and Symptoms in Patients With Dry Eye Disease
Nichols, K. K., Nichols, J. J., MPH, M., & Mitchell, G. L. (2004) · Cornea · doi:10.1097/01.ico.0000133997.07144.9e · Cited by 776 · cited 3×
“G1 Close mesh (12)/ Wave (48)/Amorphous (40) BL/G2 (0.”
Analysis of blink rate patterns in normal subjects
Bentivoglio, A. R., Bressman, S. B., Cassetta, E., Carretta, D., Tonali, P., & Albanese, A. (1997) · Movement Disorders · doi:10.1002/mds.870120629 · Cited by 512
Relation between Signs and Symptoms of Dry Eye in the Elderly
Schein, O. D., Tielsch, J. M., Muñoz, B., Bandeen-Roche, K., & West, S. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30125-0 · Cited by 438
Prevalence of Dry Eye Disease among Japanese Visual Display Terminal Users
Uchino, M., Schaumberg, D. A., Dogru, M., Uchino, Y., Fukagawa, K., Shimmura, S., Satoh, T., Takebayashi, T., & Tsubota, K. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2008.06.022 · Cited by 393
Doughty, M. J. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb01355.x · Cited by 295
Eyeblinks and Visual Suppression
Volkmann, F. C., Riggs, L. A., & Moore, R. K. (1980) · Science · doi:10.1126/science.7355270 · Cited by 270
Wolkoff, P., Nøjgaard, J. K., Troiano, P., & Piccoli, B. (2005) · Occupational and Environmental Medicine · doi:10.1136/oem.2004.016030 · Cited by 259
Computer Use, Symptoms, and Quality of Life
HAYES, J. R., SHEEDY, J. E., STELMACK, J. A., & HEANEY, C. A. (2007) · Optometry and Vision Science · doi:10.1097/opx.0b013e31812f7546 · Cited by 246
Video display terminal use and reported health symptoms among Massachusetts clerical workers.
Rossignol, A. M., Ep, M., Vm, S., & Pagnotto, L. D. (1987) · PubMed · Cited by 244
Blinking and Tear Break-Up During Four Visual Tasks
Himebaugh, N. L., Begley, C. G., Bradley, A., & Wilkinson, J. A. (2009) · Optometry and Vision Science · doi:10.1097/opx.0b013e318194e962 · Cited by 228
Synchronization of spontaneous eyeblinks while viewing video stories
Nakano, T., Yamamoto, Y., Kitajo, K., Takahashi, T., & Kitazawa, S. (2009) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2009.0828 · Cited by 225
Eyelid Movements: Behavioral Studies of Blinking in Humans Under Different Stimulus Conditions
VanderWerf, F., Brassinga, P., Reits, D., Aramideh, M., & Ongerboer de Visser, B. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00557.2002 · Cited by 197
ACOSTA, M. C., GALLAR, J., & BELMONTE, C. (1999) · Experimental Eye Research · doi:10.1006/exer.1998.0656 · Cited by 182
Eye problems and visual display terminals--the facts and the fallacies
Thomson, W. (1998) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00067-7 · Cited by 163
Ergonomics and Health in Modern Offices
Conyers, J. (1985) · Occupational and Environmental Medicine · doi:10.1136/oem.42.5.357 · Cited by 145
Freudenthaler, N., Neuf, H., Kadner, G., & Schlote, T. (2003) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-003-0786-6 · Cited by 135
A new method for measuring tears.
Hamano, H., Hori, M., Hamano, T., Mitsunaga, S., Maeshima, J., Kojima, S., Kawabe, H., & Hamano, T. (1983) · PubMed · Cited by 134
A Comparison of Seven Visual Fatigue Assessment Techniques In Three Data-Acquisition VDT Tasks
Chi, C.-F., & Lin, F.-T. (1998) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/001872098779649247 · Cited by 130
What does the Phenol Red Thread Test Actually Measure?
Tomlinson, A., Blades, K., & Pearce, E. I. (2001) · Optometry and Vision Science · doi:10.1002/j.1538-9235.2001.tb01226.x · Cited by 128
Patient-Reported Symptoms in Dry Dye Disease
Nichols, K. K. (2006) · The Ocular Surface · doi:10.1016/s1542-0124(12)70040-x · Cited by 126
Indoor Particles and Symptoms Among Office Workers: Results from a Double-Blind Cross-Over Study
Mendell, M. J., Fisk, W. J., Petersen, M. R., Hines, C. J., Dong, M., Faulkner, D. M., Deddens, J. A., Ruder, A. M., Sullivan, D. P., & Boeniger, M. F. (2002) · Epidemiology · doi:10.1097/00001648-200205000-00010 · Cited by 102
Eye blink frequency during different computer tasks quantified by electrooculography
Skotte, J. H., Nøjgaard, J. K., Jørgensen, L. V., Christensen, K. B., & Sjøgaard, G. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0322-6 · Cited by 87 · cited 1×
“Interference patterns BL Close mesh (24)/ Wave (48)/Amorphous (28) 9.”
Hultgren, G., & KNAVE, B. G. (1974) · Applied Ergonomics · doi:10.1016/0003-6870(74)90251-8 · Cited by 75
Ergonomics and health in modern offices
Grandjean, E. (1984) · International Linear Collider · Cited by 59
Dependence of visual suppression on the amplitudes of saccades and blinks
Stevenson, S. B., Volkmann, F. C., Kelly, J. P., & Riggs, L. A. (1986) · Vision Research · doi:10.1016/0042-6989(86)90133-1 · Cited by 59 · cited 1×
“Dry area extension BL 1 (60)/2 (32)/3 (8) 20.”
Office Workers and Video Display Terminals: Physical, Psychological and Ergonomic Factors
Travers, P. H., & Stanton, B.-A. (2002) · AAOHN Journal · doi:10.1177/216507990205001102 · Cited by 58
Relating posture to discomfort in VDT use.
Sj, S., Shute, S. J., & Cr, T. (1985) · PubMed · Cited by 52
The effect of blinks and saccadic eye movements on visual reaction times
Johns, M. W., Crowley, K. E., Chapman, R. J., Tucker, A., & Hocking, C. (2009) · Attention Perception & Psychophysics · doi:10.3758/app.71.4.783 · Cited by 45
LCD versus CRT Displays: A Comparison of Visual Search Performance for Colored Symbols
Hollands, J. G., Parker, H. A., McFadden, S., & Boothby, R. (2002) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1518/0018720024497862 · Cited by 36
Shieh, K.-K., & Lai, Y.-K. (2008) · Perceptual and Motor Skills · doi:10.2466/pms.107.2.336-352 · Cited by 30
Measurement of information processing load and visual load on a dynamic information processing task
Chi, C.-F., Lin, Y.-H., & Lan, W.-S. (2003) · Behaviour and Information Technology · doi:10.1080/01449290310001593621 · Cited by 18 · cited 1×
“G1 Close mesh (12)/ Wave (48)/Amorphous (40) BL/G2 (0.”
Cited by
Willcox, M. D. P., Argüeso, P., Georgiev, G. A., Holopainen, J. M., Laurie, G. W., Millar, T. J., Papas, E. B., Rolland, J. P., Schmidt, T. A., Stahl, U., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.03.006 · Cited by 995
TFOS DEWS II pain and sensation report
Belmonte, C., Nichols, J. J., Cox, S. M., Brock, J. A., Begley, C. G., Bereiter, D. A., Dartt, D. A., Galor, A., Hamrah, P., Ivanusic, J. J., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.002 · Cited by 660
Eye Movement and Pupil Measures: A Review
Mahanama, B., Jayawardana, Y., Rengarajan, S., Jayawardena, G., Chukoskie, L., Snider, J., & Jayarathna, S. (2022) · Frontiers in Computer Science · doi:10.3389/fcomp.2021.733531 · Cited by 307
Jaiswal, S., Asper, L., Long, J., Lee, A., Harrison, K., & Golebiowski, B. (2019) · Clinical and Experimental Optometry · doi:10.1111/cxo.12851 · Cited by 302
IMI – Clinical Management Guidelines Report
Gifford, K. L., Richdale, K., Kang, P., Aller, T. A., Lam, C. S., Liu, Y. M., Michaud, L., Mulder, J., Orr, J. B., Rose, K. A., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25977 · Cited by 246
Metadata
- Authors
- Cardona, G., García, C., Serés, C., Vilaseca, M., & Gispets, J.
- Venue
- Current Eye Research
- Publisher
- Informa UK Limited
- Published
- 2011-01-28
- Volume
- 36
- Issue
- 3
- Pages
- 190-197
- ISSN
- 0271-3683 (ISSN-L)
- 1460-2202
- OpenAlex
- W2079620582
- Cited by
- 238
- References
- 32
- FWCI
- 8.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.