CoChat

Increased bronchial nitric oxide production in patients with asthma measured with a novel method of different exhalation flow rates

Open access
Lehtimäki, Lauri, Turjanmaa, Väinö, Kankaanranta, Hannu, Saarelainen, Seppo, Hahtola, Paula, Moilanen, Eeva · 2000 · Annals of Medicine
Cited by 64

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The concentration of nitric oxide (NO) in exhaled air is increased in patients with asthma, suggesting that measuring fractional exhaled NO concentration (FE(NO)) may be used to monitor asthmatic airway inflammation. However, increased FE(NO) is not specific for asthma, as other inflammatory lung diseases may also increase FE(NO). To augment the specificity of FE(NO) measurement, we tested a novel theoretical modelling of pulmonary NO dynamics that allows the approximation of alveolar NO concentration and bronchial NO flux separately by measuring FE(NO) at several exhalation flow rates. We measured FE(NO) at four exhalation flow rates in 10 steroid-naive asthmatics, 5 patients with extrinsic allergic alveolitis, and in 10 healthy controls. Both the asthmatics and the patients with alveolitis had significantly higher FE(NO) than the healthy controls. The increased NO concentration originated from the bronchial level in the asthmatics and from the alveolar level in the patients with alveolitis. In the second part of the study we assessed the repeatability of FE(NO) test, within-day and day-to-day (during two weeks) variation in FE(NO), and the effects of mouth pressure and cigarette smoking on FE(NO) in healthy volunteers. Repeatability of 10 subsequent measurements was high (coefficient of variation (CV) 4.6% +/- 0.4%), and no diurnal variation was found. The day-to-day variation during a 2-week period gave a CV of 10.6% +/- 1.0%. The magnitude of mouth pressure (5-20 cmH2O in adults, 5-40 cmH2O in children) during measurement had no effect on FE(NO). Smoking a cigarette caused a small and transient but statistically significant increase in FE(NO) at 1 and 5 min after smoking. In conclusion, FE(NO) measurement is highly repeatable with low day-to-day variation among healthy subjects. Our results also suggest that the present novel method of measuring FE(NO) at several exhalation flow rates can be used to approximate alveolar and bronchial contributions to FE(NO) separately and thus increase the clinical value of this test.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/07853890008995949

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 64

Metadata

Authors
Lehtimäki, L., Turjanmaa, V., Kankaanranta, H., Saarelainen, S., Hahtola, P., & Moilanen, E.
Venue
Annals of Medicine
Published
2000-01
Volume
32
Issue
6
Pages
417-423
ISSN
  • 0785-3890 (ISSN-L)
  • 1365-2060
OpenAlex
W2043506162
Cited by
64
References
4
FWCI
2.46
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Increased bronchial nitric oxide production in patients with asthma measured with a novel method of different exhalation flow rates. https://app.cochat.ai/papers/10.3109/07853890008995949
The paper
Lehtimäki, L., Turjanmaa, V., Kankaanranta, H., Saarelainen, S., Hahtola, P., & Moilanen, E. (2000). Increased bronchial nitric oxide production in patients with asthma measured with a novel method of different exhalation flow rates. Annals of Medicine. https://doi.org/10.3109/07853890008995949

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.