The GlucoWatch®biographer: a frequent, automatic and noninvasive glucose monitor
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The GlucoWatch (Cygnus, Inc, Redwood City, CA, USA) biographer provides automatic, frequent and noninvasive blood glucose measurements for up to 12 h. The device extracts glucose through intact skin where it is measured by an amperometric biosensor. Clinical trials in a variety of environments have shown that the biographer provides accurate and precise glucose measurements when compared with serial fingerstick blood glucose measurements. Mean difference between these measurements was 0.26 mmol/L in the home environment (r = 0.80). Over 94% of biographer readings were in the clinically acceptable A+B region of the Clarke Error Grid. A slight positive bias is observed for the biographer readings at low glucose levels. Biographer precision, as measured by coefficient of variation (CV)%, is approximately 10%. The low glucose alert function of the biographer was able to detect up to 75% of hypoglycaemic episodes with a low false alert level. Skin irritation, characterized by erythema and oedema was either nonexistent or mild in over 87% of subjects and resolved in virtually all subjects without treatment in several days. The GlucoWatch biographer has been shown to be a safe and effective method to track glucose level trends and patterns, which should enable improved glycaemic control for many patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200002103420603 · Cited by 1,534
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Noninvasive Glucose Monitoring: Comprehensive Clinical Results
Tamada, J. A., Garg, S., Jovanovic, L., Pitzer, K. R., Fermi, S., Potts, R. O., & and the Cygnus Research Team (1999) · JAMA · doi:10.1001/jama.282.19.1839 · Cited by 282
Self-citation
Cited by
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Tierney, M. J., Tamada, J. A., Potts, R. O., Jovanovic, L., & Garg, S. (2001) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(01)00189-0 · Cited by 390
Self-citationPerformance Evaluation of the MiniMed® Continuous Glucose Monitoring System During Patient Home Use
Gross, T. M., Bode, B. W., Einhorn, D., Kayne, D. M., Reed, J. H., White, N. H., & Mastrototaro, J. J. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/152091500316737 · Cited by 303
Metadata
- Authors
- Tierney, M. J., Tamada, J. A., Potts, R. O., Eastman, R. C., Pitzer, K., Ackerman, N. R., & Fermi, S. J.
- Venue
- Annals of Medicine
- Publisher
- Informa UK Limited
- Published
- 2000-01
- Volume
- 32
- Issue
- 9
- Pages
- 632-641
- ISSN
- 0785-3890 (ISSN-L)
- 1365-2060
- OpenAlex
- W2087472946
- Cited by
- 154
- References
- 3
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The GlucoWatch®biographer: a frequent, automatic and noninvasive glucose monitor. https://app.cochat.ai/papers/10.3109/07853890009002034
- The paper
- Tierney, M. J., Tamada, J. A., Potts, R. O., Eastman, R. C., Pitzer, K., Ackerman, N. R., & Fermi, S. J. (2000). The GlucoWatch®biographer: a frequent, automatic and noninvasive glucose monitor. Annals of Medicine. https://doi.org/10.3109/07853890009002034
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.