Automated compared to manual office blood pressure and to home blood pressure in hypertensive patients
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We studied the relationships of automated blood pressure (BP), measured in the healthcare centre, with manual office BP and home BP. Stable outpatients treated for hypertension were measured automatically, seated alone in a quiet room, six times after a 5 min rest with the BpTRU device, and immediately afterwards using the auscultatory method. Home BP was measured in a subgroup during 7 days preceding the visit. The automated, office and home BP values were 131.2 ± 21.8/77.8 ± 12.1 mmHg, 146.9 ± 20.8/85.8 ± 12.4 mmHg and 137.7 ± 17.7/79.4 ± 8.2 mmHg, respectively. Limits of agreement between office and automated BP (2 SDs in Bland-Altman plots) were +42.6 to -12.6/+22.6 to -6.6 mmHg for systolic/diastolic BP; for home and automated BP they were +45.8 to -25.8/+20.8 to -12.6 mmHg. For patients with two visits, intraclass correlation coefficients of BP values measured during the first and second visits were 0.66/0.72 for systolic/diastolic automated BP and 0.68/0.74 for systolic/diastolic office BP. Automated BP was lower than home BP and no more closely related to home BP than to office BP. It did not show better repeatability than office BP. Whether automated BP and the "white-coat effect", calculated cas the office BP-automated BP difference, have clinical and prognostic importance deserves further studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Randomized Trial of Intensive versus Standard Blood-Pressure Control
The SPRINT Research Group (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1511939 · Cited by 6,325
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837 · cited 1×
“The data were also recalculated after the exclusion of the first day measurement, as recommended by the European guidelines for home BP monitoring,[12] and the results were practically identical (data not shown).”
Method
Cited by
2018 ESC/ESH Guidelines for the management of arterial hypertension
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy339 · Cited by 10,286
Williams, B., Mancia, G., Spiering, W., Agabiti Rosei, E., Azizi, M., Burnier, M., Clement, D. L., Coca, A., de Simone, G., Dominiczak, A., et al. (2018) · Journal of Hypertension · doi:10.1097/hjh.0000000000001940 · Cited by 2,885
Oparil, S., Acelajado, M. C., Bakris, G. L., Berlowitz, D. R., Cífková, R., Dominiczak, A. F., Grassi, G., Jordan, J., Poulter, N. R., Rodgers, A., et al. (2018) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2018.14 · Cited by 1,167
Diretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Mota-Gomes, M. A., Brandão, A. A., Feitosa, A. D. D. M., Machado, C. A., Poli-de-Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,068
Brunström, M., & Carlberg, B. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.6015 · Cited by 471
Vidal-Petiot, E., Ford, I., Greenlaw, N., Ferrari, R., Fox, K. M., Tardif, J.-C., Tendera, M., Tavazzi, L., Bhatt, D. L., & Steg, P. G. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31326-5 · Cited by 470
Lee, H.-Y., Shin, J., Kim, G.-H., Park, S., Ihm, S.-H., Kim, H. C., Kim, K.-I., Kim, J. H., Lee, J. H., Park, J.-M., et al. (2019) · Clinical Hypertension · doi:10.1186/s40885-019-0124-x · Cited by 264
Roerecke, M., Kaczorowski, J., & Myers, M. G. (2019) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.6551 · Cited by 216
Kjeldsen, S. E., Lund-Johansen, P., Nilsson, P. M., & Mancia, G. (2016) · Hypertension · doi:10.1161/hypertensionaha.116.07257 · Cited by 208
“sive people (n=353) and the difference averaged 16 mm Hg as mentioned above.(14) About mandating the sitting period, this”
Background
Metadata
- Authors
- Filipovský, J., Seidlerová, J., Kratochvíl, Z., Karnosová, P., Hronová, M., & Mayer, O.
- Venue
- Blood Pressure
- Publisher
- Informa UK Limited
- Published
- 2016-02-07
- Volume
- 25
- Issue
- 4
- Pages
- 228-234
- ISSN
- 0803-7051 (ISSN-L)
- 1651-1999
- OpenAlex
- W2271249948
- Cited by
- 149
- References
- 2
- FWCI
- 25.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.