Reaction of Ferrate (VI)/Ferrate (V) with Hydrogen Peroxide and Superoxide Anion - a Stopped-Flow and Premix Pulse Radiolysis Study
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
The reduction of ferrate(VI) to ferrate(V) by superoxide ions was studied over the pH range 2.6-13.0 using the premix pulse radiolysis technique. The pH dependence indicates that only the unstable protonated forms of ferrate, H2FeO4 (pKa3.5) and HFeO4- (pKa7.3) are reactive, k(HFeO4(-) + O2) = (1.7 +/- 0.2) x 10(7) M-1 s-1. The stable ferrate ion, FeO4(2-), showed no significant reactivity towards either hydrogen peroxide or superoxide anion. The rate constants for the spontaneous dimerization and decomposition of the protonated ferrates, e.g. k(HFeO4(-) + HFe04) approximately 250 M-1s-1, are orders of magnitude slower than their corresponding reduction reduction by superoxide indicating an outer-sphere mode of electron transfer for the latter process. In contrast the ferrate(VI) species H3FeO4+ (pKa = 1.6 +/- 0.2), H2FeO4, and HFeO4- oxidize hydrogen peroxide, e.g. k(HFeO4(-) + H2O2) = 170 M-1 s-1), at rates which correspond closely to their dimerization rates suggesting an inner-sphere controlled mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Buxton, G. V., Greenstock, C. L., Helman, W. P., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555805 · Cited by 12,332
Rate Constants for Reactions of Inorganic Radicals in Aqueous Solution
Neta, P., Huie, R. E., & Ross, A. B. (1988) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555808 · Cited by 3,651
Reactivity of HO2/O− 2 radicals in aqueous solution
Bielski, B. H. J., Cabelli, D. E., Arudi, R. L., & Ross, A. B. (1985) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555739 · Cited by 2,169
Self-citationReduction potentials of one-electron couples involving free radicals in aqueous solution
Wardman, P. (1989) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555843 · Cited by 2,123
(1966) · Index to Reviews, Symposia Volumes and Monographs in Organic Chemistry · doi:10.1016/b978-0-08-012210-6.50069-7 · Cited by 838
Aliphatic hydroxylation via oxygen rebound. Oxygen transfer catalyzed by iron
Groves, J. T., & McClusky, G. A. (1976) · Journal of the American Chemical Society · doi:10.1021/ja00419a049 · Cited by 482
Radiation Physics and Chemistry
Ohno, K. (2018) · EPR Imaging and In Vivo EPR · doi:10.1201/9781351071888-22 · Cited by 380
Rush, J. D., & Bielski, B. H. J. (1985) · The Journal of Physical Chemistry · doi:10.1021/j100269a035 · Cited by 339
Self-citationPreparation and Purification of Potassium Ferrate. VI
Thompson, G. W., Ockerman, L. T., & Schreyer, J. M. (1951) · Journal of the American Chemical Society · doi:10.1021/ja01147a536 · Cited by 280
Free radicals generated by radiolysis of aqueous solutions
Schwarz, H. A. (1981) · Journal of Chemical Education · doi:10.1021/ed058p101 · Cited by 232
Cited by
Superoxide Ion: Generation and Chemical Implications
Hayyan, M., Hashim, M. A., & AlNashef, I. M. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00407 · Cited by 2,180
Potassium ferrate(VI): an environmentally friendly oxidant
Sharma, V. K. (2002) · Advances in Environmental Research · doi:10.1016/s1093-0191(01)00119-8 · Cited by 493
Ferrate(VI) and ferrate(V) oxidation of organic compounds: Kinetics and mechanism
Sharma, V. K. (2013) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2012.04.014 · Cited by 373
Lee, Y., Zimmermann, S. G., Kieu, A. T., & von Gunten, U. (2009) · Environmental Science & Technology · doi:10.1021/es803588k · Cited by 336
Reaction of Ferrate(VI) with ABTS and Self-Decay of Ferrate(VI): Kinetics and Mechanisms
Lee, Y., Kissner, R., & von Gunten, U. (2014) · Environmental Science & Technology · doi:10.1021/es500804g · Cited by 331
Oxidation of inorganic contaminants by ferrates (VI, V, and IV)–kinetics and mechanisms: A review
Sharma, V. K. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.026 · Cited by 321
Lee, Y., Um, I.-H., & Yoon, J. (2003) · Environmental Science & Technology · doi:10.1021/es034203+ · Cited by 299
Spectrophotometric determination of ferrate (Fe(VI)) in water by ABTS
Lee, Y., Yoon, J., & von Gunten, U. (2005) · Water Research · doi:10.1016/j.watres.2005.03.005 · Cited by 251
Overlooked Role of Fe(IV) and Fe(V) in Organic Contaminant Oxidation by Fe(VI)
Zhu, J., Yu, F., Meng, J., Shao, B., Dong, H., Chu, W., Cao, T., Wei, G., Wang, H., & Guan, X. (2020) · Environmental Science & Technology · doi:10.1021/acs.est.0c03212 · Cited by 246
Sharma, V. K. (2010) · Environmental Science & Technology · doi:10.1021/es1005187 · Cited by 229
Sharma, V. K. (2008) · Chemosphere · doi:10.1016/j.chemosphere.2008.08.033 · Cited by 212
“The oxidations are strongly pH dependent and the k vary from 3.0 10 2 to 1.7 107 M 1 s 1 (Rush et al., 1996; Sharma, 2002).”
BackgroundInfluentialReactive High-Valent Iron Intermediates in Enhancing Treatment of Water by Ferrate
Sharma, V. K., Feng, M., Dionysiou, D. D., Zhou, H.-C., Jinadatha, C., Manoli, K., Smith, M. F., Luque, R., Ma, X., & Huang, C.-H. (2022) · Environmental Science & Technology · doi:10.1021/acs.est.1c04616 · Cited by 171
A mini review of preoxidation to improve coagulation
Xie, P., Chen, Y., Ma, J., Zhang, X., Zou, J., & Wang, Z. (2016) · Chemosphere · doi:10.1016/j.chemosphere.2016.04.003 · Cited by 171
Huang, Z.-S., Wang, L., Liu, Y.-L., Zhang, H.-Y., Zhao, X.-N., Bai, Y., & Ma, J. (2021) · Water Research · doi:10.1016/j.watres.2021.117094 · Cited by 158
Jiang, Y., Goodwill, J. E., Tobiason, J. E., & Reckhow, D. A. (2015) · Environmental Science & Technology · doi:10.1021/es505516w · Cited by 147
Advances in the development and application of ferrate(VI) for water and wastewater treatment
Jiang, J. (2014) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4214 · Cited by 146
Research progress in the electrochemical synthesis of ferrate(VI)
Mácová, Z., Bouzek, K., Híveš, J., Sharma, V. K., Terryn, R. J., & Baum, J. C. (2009) · Electrochimica Acta · doi:10.1016/j.electacta.2008.11.034 · Cited by 141
Metadata
- Authors
- Rush, J. D., Zhao, Z., & Bielski, B. H. J.
- Venue
- Free Radical Research
- Publisher
- Informa UK Limited
- Published
- 1996-01
- Volume
- 24
- Issue
- 3
- Pages
- 187-198
- ISSN
- 1029-2470 (ISSN-L)
- 1071-5762
- OpenAlex
- W2086222466
- Cited by
- 181
- References
- 29
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.