FRACAS: a System for Computer-Aided Image-Guided Long Bone Fracture Surgery
The DOI matches its Crossref record.
Abstract
This article describes FRACAS, a computer-integrated orthopedic system for assisting surgeons in performing closed medullary nailing of long bone fractures. FRACAS's goal is to reduce the surgeon's cumulative exposure to radiation and surgical complications associated with alignment and positioning errors of bone fragments, nail insertion, and distal screw locking. It replaces uncorrelated, static fluoroscopic images with a virtual reality display of three-dimensional bone models created from preoperative computed tomography and tracked intraoperatively in real time. Fluoroscopic images are used to register the bone models to the intraoperative situation and to verify that the registration is maintained. This article describes the system concept, software prototypes of preoperative modules (modeling, nail selection, and visualization), intraoperative modules (fluoroscopic image processing and tracking), and preliminary in vitro experimental results to date. Our experiments suggest that the modeling, nail selection, and visualization modules yield adequate results and that fluoroscopic image processing with submillimetric accuracy is practically feasible on clinical images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Image-Guided Interventions: Technology Review and Clinical Applications
Cleary, K., & Peters, T. M. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105249 · Cited by 453
Frontiers of Medical Robotics: From Concept to Systems to Clinical Translation
Troccaz, J., Dagnino, G., & Yang, G.-Z. (2019) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-060418-052502 · Cited by 194
The History of Robotics in Surgical Specialties
Shah, J., Vyas, A., & Vyas, D. (2014) · American Journal of Robotic Surgery · doi:10.1166/ajrs.2014.1006 · Cited by 189
Computer-assisted Orthopedic Surgery
Sugano, N. (2003) · Journal of Orthopaedic Science · doi:10.1007/s10776-002-0623-6 · Cited by 184
Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
Livyatan, H., Yaniv, Z., & Joskowicz, L. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.819288 · Cited by 176
“We plan to embed the algorithm in navigation and positioning systems for minimally invasive and percutaneous orthopaedic procedures, including the FRACAS system for long bone fracture reduction [3], the MARS robot for percutaneous spinal pedicle screw insertion [48], and a new system for percutaneous pelvic fraction r…”
MethodSelf-citationZheng, G., Gollmer, S., Schumann, S., Dong, X., Feilkas, T., & González Ballester, M. A. (2009) · Medical Image Analysis · doi:10.1016/j.media.2008.12.003 · Cited by 158
Computer Aided Orthopaedic Surgery: Incremental Shift or Paradigm Change?
Joskowicz, L., & Hazan, E. J. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.06.036 · Cited by 58
Self-citationPose Estimation of Periacetabular Osteotomy Fragments With Intraoperative X-Ray Navigation
Grupp, R. B., Hegeman, R. A., Murphy, R. J., Alexander, C. P., Otake, Y., McArthur, B. A., Armand, M., & Taylor, R. H. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2915165 · Cited by 38
Grupp, R. B., Armand, M., & Taylor, R. H. (2018) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-01201-4_17 · Cited by 23
Metadata
- Authors
- Joskowicz, L., Milgrom, C., Simkin, A., Tockus, L., & Yaniv, Z.
- Venue
- Computer Aided Surgery
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 3
- Issue
- 6
- Pages
- 271-288
- ISSN
- 1092-9088 (ISSN-L)
- 1097-0150
- OpenAlex
- W4240260800
- Cited by
- 97
- References
- 0
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.