Role of liquid chromatography–high-resolution mass spectrometry (LC-HR/MS) in clinical toxicology
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Gas chromatography (GC) and liquid chromatography (LC) coupled with mass spectrometry (MS) are widely used to confirm drug screening results and for urine screening in presumed intoxicated patients. These techniques are better suited to targeted analysis than to general unknown screening and, due to the complexity of testing, results are seldom available rapidly enough to contribute to the immediate care of the patient. High resolution (HR)/MS with time-of-flight (TOF) or orbitrap instruments offer potential advantages in clinical toxicology. COMPARISON OF GC-MS, LC-MS/MS AND LC-HR/MS: For unknown analyses, GC-MS and LC-MS/MS require comparison of full-scan spectra against preestablished libraries. Operation in full-scan mode greatly reduces sensitivity and some drugs present in low but significant concentrations may be missed. Selected ion monitoring (SIM) in GC/MS and selected reaction monitoring (SRM) in LC-MS/MS, where only targeted ions are monitored, increase sensitivity but require prior knowledge of what compound is to be measured. LC-HR/MS offers mass assignment with an accuracy of 0.001 atomic mass units (amu) compared with 1 amu in conventional MS. Tentative identification is thus directed to a very limited set of compounds (or even one unique compound) based on the exact molecular formula rather than a fragmentation pattern, since HR/MS can discriminate between compounds with the same nominal molecular mass. LC-MS/MS has clear advantages over GC/MS in ease and speed of sample preparation and the opportunities for its automation. LC-HR/MS is more suitable to clinical toxicology because the drugs present in a sample are rarely known a priori, and tentative identifications of unknowns can be made without the availability of a reference standard or a library spectrum. Blood can be used in preference to urine which is more relevant to the patient's current clinical situation. METHODS: A literature search was conducted using PUBMED for clinical toxicology, adulterants in illicit drugs and herbal supplements, and case reports using LC-TOF/MS and LC-HR/MS. Only 42 papers in English were identified in these searches. LC-HR/MS IN CLINICAL TOXICOLOGY: LC-HR/MS has been used to detect designer drugs, doping agents, (neurosteroids) and adulterants such as levamisole, a veterinary antihelmitic found in street cocaine, and pharmaceuticals in herbal medications marketed to contain only natural ingredients. LC-HR/MS has proved useful for cases where existing tests were unable to identify the cause of the intoxication. One patient suffered a drug-induced seizure which was originally thought to be caused by an herbal medication, but diphenhydramine was determined to be the culprit. In another, 5-oxoproline was identified as the cause of metabolic acidosis seen in chronic acetaminophen (paracetamol) use. LC-HR/MS has successfully identified medications that were mislabeled or misrepresented street drugs. In one case, medications sold as diazepam were determined to be glyburide instead. The identification of novel designer amines, stimulants found in "bath salts", and synthetic cannabinoids are well suited to LC-HR/MS. Dozens or even hundreds of possible compounds cannot realistically be tested on an individual basis by targeted LC-MS/MS or GC/MS analysis. CONCLUSIONS: LC-HR/MS offers unique opportunities for time-sensitive clinical analysis of blood samples from intoxicated patients and for comprehensive screening in a wide range of situations and materials. While the identification is not as definitive as that obtained by conventional fragmentation MS, the presumptive identification can be confirmed later with standards and spectral library matches. Optimum utilization of the presumptive diagnosis requires close collaboration between the laboratory analysts and their clinical counterparts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matuszewski, B. K., Constanzer, M. L., & Chavez-Eng, C. M. (2003) · Analytical Chemistry · doi:10.1021/ac020361s · Cited by 5,335
Bronstein, A. C., Spyker, D. A., Cantilena, L. R., Green, J. L., Rumack, B. H., & Dart, R. C. (2011) · Clinical Toxicology · doi:10.3109/15563650.2011.635149 · Cited by 388
Dresen, S., Ferreirós, N., Pütz, M., Westphal, F., Zimmermann, R., & Auwärter, V. (2010) · Journal of Mass Spectrometry · doi:10.1002/jms.1811 · Cited by 309
Adulterants in illicit drugs: a review of empirical evidence
Cole, C., Jones, L., McVeigh, J., Kicman, A., Syed, Q., & Bellis, M. (2011) · Drug Testing and Analysis · doi:10.1002/dta.220 · Cited by 281
Wu, A. H. B., McKay, C. A., Broussard, L. A., Hoffman, R. S., Kwong, T. C., Moyer, T. P., Otten, E. M., Welch, S. L., & Wax, P. M. (2003) · Clinical Chemistry · doi:10.1373/49.3.357 · Cited by 250
Self-citation“Spice” Girls: Synthetic Cannabinoid Intoxication
Schneir, A. B., Cullen, J., & Ly, B. T. (2011) · The Journal of Emergency Medicine · doi:10.1016/j.jemermed.2010.10.014 · Cited by 215
Lacorte, S., & Fernandez‐Alba, A. R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20094 · Cited by 204
Remane, D., Wissenbach, D. K., & Peters, F. T. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.07.010 · Cited by 203
Identification of a Cannabinoid Analog as a New Type of Designer Drug in a Herbal Product
Uchiyama, N., Kikura-Hanajiri, R., Kawahara, N., Haishima, Y., & Goda, Y. (2009) · Chemical and Pharmaceutical Bulletin · doi:10.1248/cpb.57.439 · Cited by 172
Ferrer, I. (2003) · TrAC Trends in Analytical Chemistry · doi:10.1016/s0165-9936(03)01013-6 · Cited by 170
Cited by
Fentanyl, fentanyl analogs and novel synthetic opioids: A comprehensive review
Armenian, P., Vo, K. T., Barr-Walker, J., & Lynch, K. L. (2018) · Neuropharmacology · doi:10.1016/j.neuropharm.2017.10.016 · Cited by 710
Self-citationKocherlakota, P. (2014) · Pediatrics · doi:10.1542/peds.2013-3524 · Cited by 612
Gorrochategui, E., Jaumot, J., Lacorte, S., & Tauler, R. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.07.004 · Cited by 352
Remane, D., Wissenbach, D. K., & Peters, F. T. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.07.010 · Cited by 203
Strathmann, F. G., Schulte, S., Goerl, K., & Petron, D. J. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.01.028 · Cited by 98
Metadata
- Authors
- Wu, A. H., Gerona, R., Armenian, P., French, D., Petrie, M., & Lynch, K. L.
- Venue
- Clinical Toxicology
- Publisher
- Informa UK Limited
- Published
- 2012-08-13
- Volume
- 50
- Issue
- 8
- Pages
- 733-742
- ISSN
- 0009-9309 (ISSN-L)
- 1556-3650
- 1556-9519
- OpenAlex
- W1993754270
- Cited by
- 184
- References
- 36
- FWCI
- 17.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.