Visible and near-infrared spectroscopic analysis of raw milk for cow health monitoring: Reflectance or transmittance?
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The composition of produced milk has great value for the dairy farmer. It determines the economic value of the milk and provides valuable information about the metabolism of the corresponding cow. Therefore, online measurement of milk components during milking 2 or more times per day would provide knowledge about the current health and nutritional status of each cow individually. This information provides a solid basis for optimizing cow management. The potential of visible and near-infrared (Vis/NIR) spectroscopy for predicting the fat, crude protein, lactose, and urea content of raw milk online during milking was, therefore, investigated in this study. Two measurement modes (reflectance and transmittance) and different wavelength ranges for Vis/NIR spectroscopy were evaluated and their ability to measure the milk composition online was compared. The Vis/NIR reflectance measurements allowed for very accurate monitoring of the fat and crude protein content in raw milk (R(2)>0.95), but resulted in poor lactose predictions (R(2)<0.75). In contrast, Vis/NIR transmittance spectra of the milk samples gave accurate fat and crude protein predictions (R(2)>0.90) and useful lactose predictions (R(2)=0.88). Neither Vis/NIR reflectance nor transmittance spectroscopy lead to an acceptable prediction of the milk urea content. Transmittance spectroscopy can thus be used to predict the 3 major milk components, but with lower accuracy for fat and crude protein than the reflectance mode. Moreover, the small sample thickness (1mm) required for NIR transmittance measurement considerably complicates its online use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International Organization for Standardization
(2015) · Encyclopedia of Astrobiology · doi:10.1007/978-3-662-44185-5_100574 · Cited by 6,716
Near-Infrared Technology: In the Agricultural and Food Industries
Williams, P. C., & Norris, K. (2001) · Andalas University Repository (Andalas University) · Cited by 2,749
Haaland, D. M., & Thomas, E. V. (1988) · Analytical Chemistry · doi:10.1021/ac00162a020 · Cited by 2,539 · cited 1×
“The model complexity was optimized by choosing the lowest number of latent variables for which the cumulative prediction error was not significantly worse than the lowest error obtained with up to 20 latent variables (Haaland and Thomas, 1988).”
Nondestructive measurement of fruit and vegetable quality by means of NIR spectroscopy: A review
Nicolaï, B. M., Beullens, K., Bobelyn, E., Peirs, A., Saeys, W., Theron, K. I., & Lammertyn, J. (2007) · Postharvest Biology and Technology · doi:10.1016/j.postharvbio.2007.06.024 · Cited by 2,252 · cited 1×
“Visible and near-infrared (Vis/NIR) spectroscopy is a valuable technique for rapid, non-destructive, and online analysis of the quality and composition of agricultural products (Saeys et al., 2005; Nicolaï et al., 2007; Huang et al., 2008).”
Self-citationISO (International Organization for Standardization)
Nollet, L. M. L. (2019) · Testing and Analysis of GMO-containing Foods and Feed · doi:10.1201/9781315178592-10 · Cited by 1,895
Validation of Regression Models: Methods and Examples
Snee, R. D. (1977) · Technometrics · doi:10.1080/00401706.1977.10489581 · Cited by 1,283 · cited 1×
“The sets of raw milk samples were separated in a calibration set of two-thirds (200 samples) and a test set of one-thirds (100 samples) by applying the duplex algorithm (Snee, 1977) on the reference composition data.”
Practical Guide to Interpretive Near-Infrared Spectroscopy
Workman, Jr., & Weyer, L. (2007) · CRC Press eBooks · doi:10.1201/9781420018318 · Cited by 1,144 · cited 1×
“Moreover, the most important NIR absorption peaks for urea are located in a region having a high absorption by water (1,990–2,250 nm; Workman and Weyer, 2007).”
Subacute ruminal acidosis in dairy cows: The physiological causes, incidence and consequences
Plaizier, J. C., Krause, D. O., Gozho, G. N., & McBride, B. W. (2008) · The Veterinary Journal · doi:10.1016/j.tvjl.2007.12.016 · Cited by 1,003 · cited 1×
“Milk fat depression could imply subacute ruminal acidosis (Plaizier et al., 2008).”
Dairy Technology: Principles of Milk Properties and Processes
Walstra, P., Geurts, T. J., Noomen, A., Jellema, A., & van Boekel, M. A. J. S. (1999) · Socio-Environmental Systems Modeling · Cited by 625
Near infrared spectroscopy for on/in-line monitoring of quality in foods and beverages: A review
Huang, H., Yu, H., Xu, H., & Ying, Y. (2008) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2007.12.022 · Cited by 560 · cited 1×
“Visible and near-infrared (Vis/NIR) spectroscopy is a valuable technique for rapid, non-destructive, and online analysis of the quality and composition of agricultural products (Saeys et al., 2005; Nicolaï et al., 2007; Huang et al., 2008).”
Saeys, W., Mouazen, A. M., & Ramón, H. (2005) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2005.05.001 · Cited by 540 · cited 5×
“Both models allow for rough screening of the lactose content in raw milk (Saeys et al., 2005).”
InfluentialSelf-citationBiological applications of infrared spectroscopy
Stuart, B. H., & Ando, D. (1997) · Medical Entomology and Zoology · Cited by 339
A herd health approach to dairy cow nutrition and production diseases of the transition cow
Mulligan, F. J., O’Grady, L., Rice, D. A., & Doherty, M. L. (2006) · Animal Reproduction Science · doi:10.1016/j.anireprosci.2006.08.011 · Cited by 235 · cited 3×
“Changes in the milk composition (e.g., somatic cells, lactose, minerals, and enzymes) can also be attributed to a disease-combating response of the cow in the case of mastitis, decreased secretory activity, and alteration of the blood-milk barrier (Mulligan et al., 2006).”
InfluentialŠašić, S., & Ozaki, Y. (2000) · Analytical Chemistry · doi:10.1021/ac000469c · Cited by 225 · cited 2×
“Absorption of NIR radiation by the first overtone of C–H stretch vibrations occurred between 1,660 and 1,730 nm (Šaši and Ozaki, 2001), indicated by high PLS regression coefficients for fat prediction based on the transmittance spectra (Figure 4).”
Near-Infrared Spectroscopy for Dairy Management: Measurement of Unhomogenized Milk Composition
Tsenkova, R., Atanassova, S., Toyoda, K., Ozaki, Y., Itoh, K., & Fearn, T. (1999) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(99)75484-6 · Cited by 212 · cited 8×
“When measurements were limited to the Si range (400–1,100 nm) best results were obtained with a path length of 10 mm (Tsenkova et al., 1999) to 13.6 mm (Saranwong and Kawano, 2008).”
InfluentialMilk fat globule size is affected by fat production in dairy cows
Wiking, L., Stagsted, J., Björck, L., & Nielsen, J. H. (2004) · International Dairy Journal · doi:10.1016/j.idairyj.2004.03.005 · Cited by 169 · cited 1×
“These scatter phenomena are most likely caused by fat globules whose size and number are related to the milk fat content (Wiking et al., 2004).”
Near-Infrared Analysis of Fat, Protein, and Casein in Cow's Milk
Laporte, M.-F., & Paquin, P. (1999) · Journal of Agricultural and Food Chemistry · doi:10.1021/jf980929r · Cited by 166
Frank, B., & Swensson, C. (2002) · Journal of Dairy Science · doi:10.3168/jds.s0022-0302(02)74257-4 · Cited by 149 · cited 1×
“For example, the urea content, together with the protein content of the produced milk, indicate the balance between protein and energy in the rumen and can be used to optimize the efficiency of nitrogen utilization (Frank and Swensson, 2002).”
Near-infrared spectroscopic sensing system for on-line milk quality assessment in a milking robot
Kawasaki, M., Kawamura, S., Tsukahara, M., Morita, S., Komiya, M., & Natsuga, M. (2008) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2008.01.006 · Cited by 134 · cited 3×
“Journal of Dairy Science Vol. 94 No. 11, 2011 and Šustová (2003) and Kawasaki et al. (2008) obtained inadequate results with coefficient of determination below 0.68 for an independent test set.”
InfluentialNear-infrared spectroscopic sensing system for online monitoring of milk quality during milking
Kawamura, S., Kawasaki, M., Nakatsuji, H., & Natsuga, M. (2007) · Sensing and Instrumentation for Food Quality and Safety · doi:10.1007/s11694-006-9001-x · Cited by 93 · cited 3×
“Nevertheless, Kawamura et al. (2007) reported very good results (R2 = 0.9) for urea prediction for an independent set of milk samples by using only the short wavelength range (600–1,050 nm).”
InfluentialReview of systems for monitoring curd setting during cheesemaking
O'Callaghan, D. J., O’Donnell, C. P., & Payne, F. A. (2002) · International Journal of Dairy Technology · doi:10.1046/j.1471-0307.2002.00043.x · Cited by 92 · cited 1×
“Because cheese and milk powder are too dense to measure Vis/NIR transmittance, reflectance measurements are typically used (Barabássy, 2001; O’Callaghan et al., 2002).”
Czarnik‐Matusewicz, B., Murayama, K., Tsenkova, R., & Ozaki, Y. (1999) · Applied Spectroscopy · doi:10.1366/0003702991946046 · Cited by 83 · cited 1×
“…1,000 to 1,700 nm for reflectance and 1,000 to 2,500 nm for transmittance were found to be very informative for CP detection in milk (Figure 6), probably because this range included the first-overtone amide B absorption band (Figures 3 and 4) at 1,640 to 1,670 nm (Czarnik-Matusewicz et al.,1999).”
Saranwong, S., & Kawano, S. (2008) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.807 · Cited by 39 · cited 2×
“Several researchers have shown the potential of Vis/NIR spectroscopic analysis of raw milk in the reflectance, transmittance, or transflectance mode for reliable determination of the fat, protein, and lactose concentration in the laboratory (Laporte and Paquin, 1999; Purnomoadi et al., 1999; Tsenkova et al., 1999; Jan…”
Influence of feed source on determination of fat and protein in milk by near-infrared spectroscopy
Purnomoadi, A., Batajoo, K. K., Ueda, K., & Terada, F. (1999) · International Dairy Journal · doi:10.1016/s0958-6946(99)00050-3 · Cited by 27 · cited 5×
“…transmittance, or transflectance mode for reliable determination of the fat, protein, and lactose concentration in the laboratory (Laporte and Paquin, 1999; Purnomoadi et al., 1999; Tsenkova et al., 1999; Jankovská and Šustová, 2003; Navrátilová et al., 2006; Saranwong and Kawano, 2008).”
Influential
Metadata
- Authors
- Aernouts, B., Polshin, E., Lammertyn, J., & Saeys, W.
- Venue
- Journal of Dairy Science
- Publisher
- American Dairy Science Association
- Published
- 2011-11
- Volume
- 94
- Issue
- 11
- Pages
- 5315-5329
- ISSN
- 0022-0302 (ISSN-L)
- OpenAlex
- W2055157917
- Cited by
- 159
- References
- 24
- FWCI
- 3.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.