Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 293

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum

Open access
Quigley, J.D., Lago, A., Chapman, C., Erickson, P., Polo, J. · 2013 · Journal of Dairy Science

Abstract

Refractometry using a Brix refractometer has been proposed as a means to estimate IgG concentration in bovine maternal colostrum (MC). The refractometer has advantages over other methods of estimating IgG concentration in that the Brix refractometer is inexpensive, readily available, less fragile, and less sensitive to variation in colostral temperature, season of the year and other factors. Samples of first-milking MC were collected from 7 dairy farms in Maine, New Hampshire, Vermont, and Connecticut (n=84) and 1 dairy farm in California (n=99). The MC was milked from the cow at 6.1 ± 5.6h postparturition and a sample was evaluated for Brix percentage by using an optical refractometer. Two additional samples (30 mL) were collected from the milk bucket, placed in vials, and frozen before analysis of total IgG by radial immunodiffusion (RID) using commercially available plates and by turbidimetric immunoassay (TIA). The second sample was analyzed for total bacterial counts and coliform counts at laboratories in New York (Northeast samples) and California (California samples). The Brix percentage (mean ± SD) was 23.8 ± 3.5, IgG concentration measured by RID was 73.4 ± 26.2g/L, and IgG concentration measured by TIA was 67.5 ± 25.0 g/L. The Brix percentage was highly correlated (r=0.75) with IgG analyzed by RID. The Brix percentage cut point to define high- or low-quality colostrum (50 g of IgG/L measured by RID) that classified more samples correctly given the proportion of high- (86%) and low-quality (14%) samples in this study was 21%, which is slightly lower than other recent estimates of Brix measurements. At this cut point, the test sensitivity, specificity, positive and negative predictive values, and accuracy were 92.9, 65.5, 93.5, 63.3, and 88.5%, respectively. Measurement of IgG by TIA correlated with Brix (r=0.63) and RID (r=0.87); however, TIA and RID methods of IgG measurement were not consistent throughout the range of samples tested. We conclude that Brix measurement of total solids in fresh MC is an inexpensive, rapid, and satisfactorily accurate method of estimating IgG concentration. A cut point of 21% Brix to estimate samples of MC >50 g/L was most appropriate for our data. Measurement of IgG in MC by TIA differed from measurement by RID.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3168/jds.2012-5823

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 293

Metadata

Authors
Quigley, J. D., Lago, A., Chapman, C., Erickson, P., & Polo, J.
Venue
Journal of Dairy Science
Published
2013-02
Volume
96
Issue
2
Pages
1148-1155
ISSN
0022-0302 (ISSN-L)
OpenAlex
W2096645568
Cited by
293
References
14
FWCI
11.51
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum. https://app.cochat.ai/papers/10.3168/jds.2012-5823
The paper
Quigley, J. D., Lago, A., Chapman, C., Erickson, P., & Polo, J. (2013). Evaluation of the Brix refractometer to estimate immunoglobulin G concentration in bovine colostrum. Journal of Dairy Science. https://doi.org/10.3168/jds.2012-5823

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.