Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 292

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Reliability assessment of a novel cervical spine deformity classification system

Open access
Ames, Christopher P., Smith, Justin S., Eastlack, Robert, Blaskiewicz, Donald J., Shaffrey, Christopher I., Schwab, Frank, Bess, Shay, Kim, Han Jo, Mundis, Gregory M., Klineberg, Eric, Gupta, Munish, O’Brien, Michael, Hostin, Richard, Scheer, Justin K., Protopsaltis, Themistocles S., Fu, Kai-Ming G., Hart, Robert, Albert, Todd J., Riew, K. Daniel, Fehlings, Michael G., Deviren, Vedat, Lafage, Virginie, _, _·2015·Journal of Neurosurgery: Spine

Abstract

OBJECT: Despite the complexity of cervical spine deformity (CSD) and its significant impact on patient quality of life, there exists no comprehensive classification system. The objective of this study was to develop a novel classification system based on a modified Delphi approach and to characterize the intra- and interobserver reliability of this classification. METHODS: Based on an extensive literature review and a modified Delphi approach with an expert panel, a CSD classification system was generated. The classification system included a deformity descriptor and 5 modifiers that incorporated sagittal, regional, and global spinopelvic alignment and neurological status. The descriptors included: “C,” “CT,” and “T” for primary cervical kyphotic deformities with an apex in the cervical spine, cervicothoracic junction, or thoracic spine, respectively; “S” for primary coronal deformity with a coronal Cobb angle ≥ 15°; and “CVJ” for primary craniovertebral junction deformity. The modifiers included C2–7 sagittal vertical axis (SVA), horizontal gaze (chin-brow to vertical angle [CBVA]), T1 slope (TS) minus C2–7 lordosis (TS–CL), myelopathy (modified Japanese Orthopaedic Association [mJOA] scale score), and the Scoliosis Research Society (SRS)-Schwab classification for thoracolumbar deformity. Application of the classification system requires the following: 1) full-length standing posteroanterior (PA) and lateral spine radiographs that include the cervical spine and femoral heads; 2) standing PA and lateral cervical spine radiographs; 3) completed and scored mJOA questionnaire; and 4) a clinical photograph or radiograph that includes the skull for measurement of the CBVA. A series of 10 CSD cases, broadly representative of the classification system, were selected and sufficient radiographic and clinical history to enable classification were assembled. A panel of spinal deformity surgeons was queried to classify each case twice, with a minimum of 1 intervening week. Inter- and intrarater reliability measures were based on calculations of Fleiss k coefficient values. RESULTS: Twenty spinal deformity surgeons participated in this study. Interrater reliability (Fleiss k coefficients) for the deformity descriptor rounds 1 and 2 were 0.489 and 0.280, respectively, and mean intrarater reliability was 0.584. For the modifiers, including the SRS-Schwab components, the interrater (round 1/round 2) and intrarater reliabilities (Fleiss k coefficients) were: C2–7 SVA (0.338/0.412, 0.584), horizontal gaze (0.779/0.430, 0.768), TS-CL (0.721/0.567, 0.720), myelopathy (0.602/0.477, 0.746), SRS-Schwab curve type (0.590/0.433, 0.564), pelvic incidence-lumbar lordosis (0.554/0.386, 0.826), pelvic tilt (0.714/0.627, 0.633), and C7-S1 SVA (0.071/0.064, 0.233), respectively. The parameter with the poorest reliability was the C7–S1 SVA, which may have resulted from differences in interpretation of positive and negative measurements. CONCLUSIONS: The proposed classification provides a mechanism to assess CSD within the framework of global spinopelvic malalignment and clinically relevant parameters. The intra- and interobserver reliabilities suggest moderate agreement and serve as the basis for subsequent improvement and study of the proposed classification.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2014.12.spine14780

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Metadata

Authors
Ames, C. P., Smith, J. S., Eastlack, R., Blaskiewicz, D. J., Shaffrey, C. I., Schwab, F., Bess, S., Kim, H. J., Mundis, G. M., Klineberg, E., Gupta, M., O’Brien, M., Hostin, R., Scheer, J. K., Protopsaltis, T. S., Fu, K.-M. G., Hart, R., Albert, T. J., Riew, K. D., Fehlings, M. G., Deviren, V., Lafage, V., & _, _.
Venue
Journal of Neurosurgery: Spine
Published
2015-12
Volume
23
Issue
6
Pages
673-683
ISSN
  • 1547-5646 (ISSN-L)
  • 1547-5654
OpenAlex
W2155291098
Cited by
292
References
12
FWCI
19.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability assessment of a novel cervical spine deformity classification system. https://app.cochat.ai/papers/10.3171/2014.12.spine14780
The paper
Ames, C. P., Smith, J. S., Eastlack, R., Blaskiewicz, D. J., Shaffrey, C. I., Schwab, F., Bess, S., Kim, H. J., Mundis, G. M., Klineberg, E., Gupta, M., O’Brien, M., Hostin, R., Scheer, J. K., Protopsaltis, T. S., Fu, K.-M. G., Hart, R., Albert, T. J., Riew, K. D., . . . _, _. (2015). Reliability assessment of a novel cervical spine deformity classification system. Journal of Neurosurgery: Spine. https://doi.org/10.3171/2014.12.spine14780

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.