CoChat

Potential utility of FLAIR in MRI-negative Cushing’s disease

Open access
Chatain, Grégoire P., Patronas, Nicholas, Smirniotopoulos, James G., Piazza, Martin, Benzo, Sarah, Ray-Chaudhury, Abhik, Sharma, Susmeeta, Lodish, Maya, Nieman, Lynnette, Stratakis, Constantine A., Chittiboina, Prashant · 2018 · Journal of Neurosurgery
Cited by 48

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: Accurate presurgical localization of microadenomas in Cushing’s disease (CD) leads to improved remission rates and decreased adverse events. Volumetric gradient recalled echo (3D-GRE) MRI detects pituitary microadenomas in CD in up to 50%–80% cases as a focus of hypointensity due to delayed contrast wash-in. The authors have previously reported that postcontrast FLAIR imaging may be useful in detecting otherwise MRI-negative pituitary microadenomas as foci of hyperintensity. This reflects theoretically complementary imaging of microadenomas due to delayed contrast washout. The authors report on the diagnostic accuracy and clinical utility of FLAIR imaging in the detection of microadenomas in patients with CD. METHODS: The authors prospectively analyzed imaging findings in 23 patients (24 tumors) with biochemically proven CD who underwent transsphenoidal surgery for CD. Preoperatively, the patients underwent pituitary MRI with postcontrast FLAIR and postcontrast 3D-GRE sequences. RESULTS: Postcontrast FLAIR hyperintensity was detected in macroadenomas, and in 3D-GRE–positive or –negative microadenomas. Overall, 3D-GRE was superior in detecting surgically and histopathologically confirmed, location-concordant microadenomas. Of 24 pituitary adenomas, 18 (75%; sensitivity 82%, positive predictive value 95%) were found on 3D-GRE, and 13 (50% [1 was false positive]; sensitivity 55%, positive predictive value 92%) were correctly identified on FLAIR. The stand-alone specificity of 3D-GRE and FLAIR was similar (50%). These results confirm the superiority of 3D-GRE as a stand-alone imaging modality. The authors then tested the utility of FLAIR as a complementary tool to 3D-GRE imaging. All 5 patients with negative 3D-GRE MRI displayed a distinct focus of FLAIR enhancement. Four of those 5 cases (80%) had location-concordant positive histopathological results and achieved postsurgical biochemical remission. The remaining patient was not cured, because resection did not include the region of FLAIR hyperintensity. CONCLUSIONS: This study suggests that delayed microadenoma contrast washout may be detected as FLAIR hyperintensity in otherwise MRI-negative CD cases. The authors propose adding postcontrast FLAIR sequences to complement 3D-GRE for surgical planning in patients with CD. Clinical trial registration no.: NIH protocol 03-N-0164, NCT00060541 (clinicaltrials.gov)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3171/2017.4.jns17234

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 48

Metadata

Authors
Chatain, G. P., Patronas, N., Smirniotopoulos, J. G., Piazza, M., Benzo, S., Ray-Chaudhury, A., Sharma, S., Lodish, M., Nieman, L., Stratakis, C. A., & Chittiboina, P.
Venue
Journal of Neurosurgery
Published
2018-09
Volume
129
Issue
3
Pages
620-628
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W2762579272
Cited by
48
References
4
FWCI
2.60
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.