Blood-brain barrier disruption in humans using an implantable ultrasound device: quantification with MR images and correlation with local acoustic pressure
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: One of the goals in this study was to set up a semiautomatic method to estimate blood-brain barrier disruption obtained in patients with glioblastoma by using an implantable, unfocused, ultrasound device. Another goal was to correlate the probability of significant ultrasound-induced signal enhancement (SUISE) with local acoustic pressure in the brain. METHODS: Gd-enhanced MR images acquired before and after ultrasound treatments were analyzed prospectively. The image sets were segmented, normalized, and coregistered to evaluate contrast enhancement. The volume of SUISE was calculated with voxels labeled as gray or white matter, in a cylindrical region of interest, and with enhancement above a given threshold. To validate the method, the resulting volumes of SUISE were compared to qualitative grades previously assigned by 3 clinicians for 40 ultrasound treatments in 15 patients. A parametric study was performed to optimize the algorithm prediction of the qualitative grades. The 3D acoustic field in the brain was estimated from measurements in water combined with simulations accounting for ultrasound attenuation in brain and overlaid on each MR image to correlate local acoustic pressure with the probability of SUISE (defined as enhancement > 10%). RESULTS: The algorithm predicted grade 2 or 3 and grade 3 openings with areas under the receiver operating characteristic curve of 0.831 and 0.995, respectively. The probability of SUISE was correlated with local acoustic pressure (R 2 = 0.98) and was 3.33 times higher for gray matter than for white matter. CONCLUSIONS: An algorithm for evaluating blood-brain barrier disruption was validated and can be used for future clinical trials to further understand and quantify this technique in humans. Clinical trial registration no.: NCT02253212 (clinicaltrials.gov)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
Clinical trial of blood-brain barrier disruption by pulsed ultrasound
Carpentier, A., Canney, M., Vignot, A., Reina, V., Beccaria, K., Horodyckid, C., Karachi, C., Leclercq, D., Lafon, C., Chapelon, J.-Y., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf6086 · Cited by 757
Self-citationBurgess, A., Dubey, S., Yeung, S., Hough, O., Eterman, N., Aubert, I., & Hynynen, K. (2014) · Radiology · doi:10.1148/radiol.14140245 · Cited by 286
Cited by
Nanomaterial-based blood-brain-barrier (BBB) crossing strategies
Xie, J., Shen, Z., Anraku, Y., Kataoka, K., & Chen, X. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119491 · Cited by 604
Applications of focused ultrasound in the brain: from thermoablation to drug delivery
Meng, Y., Hynynen, K., & Lipsman, N. (2021) · Nature Reviews Neurology · doi:10.1038/s41582-020-00418-z · Cited by 505
Idbaih, A., Canney, M., Belin, L., Desseaux, C., Vignot, A., Bouchoux, G., Asquier, N., Law-Ye, B., Leclercq, D., Bissery, A., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-3643 · Cited by 362
Self-citationSonabend, A. M., Gould, A., Amidei, C., Ward, R., Schmidt, K. A., Zhang, D. Y., Gomez, C., Bebawy, J. F., Liu, B. P., Bouchoux, G., et al. (2023) · The Lancet Oncology · doi:10.1016/s1470-2045(23)00112-2 · Cited by 260
Self-citationFrontiers in the treatment of glioblastoma: Past, present and emerging
Janjua, T. I., Rewatkar, P., Ahmed-Cox, A., Saeed, I., Mansfeld, F. M., Kulshreshtha, R., Kumeria, T., Ziegler, D. S., Kavallaris, M., Mazzieri, R., et al. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.01.012 · Cited by 257
Metadata
- Authors
- Asquier, N., Bouchoux, G., Canney, M., Martin, C., Law-Ye, B., Leclercq, D., Chapelon, J.-Y., Lafon, C., Idbaih, A., & Carpentier, A.
- Venue
- Journal of Neurosurgery
- Published
- 2020-03
- Volume
- 132
- Issue
- 3
- Pages
- 875-883
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2915492392
- Cited by
- 50
- References
- 3
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood-brain barrier disruption in humans using an implantable ultrasound device: quantification with MR images and correlation with local acoustic pressure. https://app.cochat.ai/papers/10.3171/2018.9.jns182001
- The paper
- Asquier, N., Bouchoux, G., Canney, M., Martin, C., Law-Ye, B., Leclercq, D., Chapelon, J.-Y., Lafon, C., Idbaih, A., & Carpentier, A. (2020). Blood-brain barrier disruption in humans using an implantable ultrasound device: quantification with MR images and correlation with local acoustic pressure. Journal of Neurosurgery. https://doi.org/10.3171/2018.9.jns182001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.