Transcranial Doppler ultrasonography in raised intra-cranial pressure and in intracranial circulatory arrest
The DOI matches its Crossref record.
Abstract
✓ Transcranial Doppler ultrasonography was used to monitor 71 patients suffering from intracranial hypertension with subsequent brain death. Among these, 29 patients were also assessed for systemic arterial pressure and epidural intracranial pressure, so that a correlation between cerebral perfusion pressure and the Doppler ultrasonography waveforms could be established. Four-vessel angiography was also performed in 33 patients after clinical brain death. With increasing intracranial pressure, the transcranial Doppler ultrasonography waveforms exhibited different characteristic high-resistance profiles with first low, then zero, and then reversed diastolic flow velocities, depending on the relationship between intracranial pressure and blood pressure (that is, cerebral perfusion pressure). This study shows that transcranial. Doppler ultrasonography may be used to assess the degree of intracranial hypertension. This technique further provides a practicable, noninvasive bedside monitor of therapeutic measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dubourg, J., Javouhey, E., Geeraerts, T., Messerer, M., & Kassai, B. (2011) · Intensive Care Medicine · doi:10.1007/s00134-011-2224-2 · Cited by 611
Sloan, M. A., Alexandrov, A. V., Tegeler, C. H., Spencer, M. P., Caplan, L. R., Feldmann, E., Wechsler, L. R., Newell, D. W., Gomez, C. R., Babikian, V. L., et al. (2004) · Neurology · doi:10.1212/wnl.62.9.1468 · Cited by 517
Assessment of cerebral pressure autoregulation in humans - a review of measurement methods
Panerai, R. B. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/3/001 · Cited by 508
Chan, K.-H., Miller, J. D., Dearden, N. M., Andrews, P. J. D., & Midgley, S. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.1.0055 · Cited by 397
Alperin, N. J., Lee, S. H., Loth, F., Raksin, P. B., & Lichtor, T. (2000) · Radiology · doi:10.1148/radiology.217.3.r00dc42877 · Cited by 327
Naqvi, J., Yap, K. H., Ahmad, G., & Ghosh, J. (2013) · International Journal of Vascular Medicine · doi:10.1155/2013/629378 · Cited by 279
The critical closing pressure of the cerebral circulation
Panerai, R. B. (2003) · Medical Engineering & Physics · doi:10.1016/s1350-4533(03)00027-4 · Cited by 219
“In head injury patients with intracranial hypertension, absence of diastolic flow or velocity, or even complete circulatory arrest, can be observed for extreme values of ICP [27].”
BackgroundIntracranial pressure in African children with cerebral malaria
NEWTON, C. (1991) · The Lancet · doi:10.1016/0140-6736(91)91638-b · Cited by 213
Czosnyka, M., Richards, H. K., Whitehouse, H. E., & Pickard, J. D. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.1.0079 · Cited by 208
European brain death codes: a comparison of national guidelines
Haupt, W. F., & Rudolf, J. (1999) · Journal of Neurology · doi:10.1007/s004150050378 · Cited by 183
Cerebral autoregulation in pediatric traumatic brain injury*
Vavilala, M. S., Lee, L. A., Boddu, K., Visco, E., Newell, D. W., Zimmerman, J. J., & Lam, A. M. (2004) · Pediatric Critical Care Medicine · doi:10.1097/01.pcc.0000123545.69133.c3 · Cited by 167
“The progression and change in flow velocity pattern with increasing ICP have been well characterized (26).”
BackgroundMeasurement of arterial blood flow by Doppler ultrasound
Hoskins, P. R. (1990) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/11/1/001 · Cited by 109
Metadata
- Authors
- Hassler, W., Steinmetz, H., & Gawlowski, J.
- Venue
- Journal of Neurosurgery
- Published
- 1988-05
- Volume
- 68
- Issue
- 5
- Pages
- 745-751
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W1209301561
- Cited by
- 335
- References
- 0
- FWCI
- 15.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.