Vagus nerve stimulation for complex partial seizures: surgical technique, safety, and efficacy
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
✓ Electrical stimulation of the vagus nerve has shown efficacy in controlling seizures in experimental models, and early clinical trials have suggested possible benefit in humans. Eleven patients with complex partial seizures were subjected to implantation of vagus nerve stimulators. Electrode contacts embedded in silicone rubber spirals were placed on the left vagus nerve in the low cervical area. A transcutaneously programmable stimulator module was placed in an infraclavicular subcutaneous pocket and connected to the electrode. One patient required replacement of the system due to electrode fracture. Another patient developed delayed ipsilateral vocal-cord paralysis; the technique was then modified to allow more tolerance for postoperative nerve edema. A third patient showed asymptomatic vocal-cord paresis on immediate postoperative laryngoscopy. Vagus nerve stimulation produces transient vocal-cord dysfunction while the current is on. Nine patients were randomly assigned to receive either high- or low-current stimulation, and seizure frequency was recorded. The high-current stimulation group showed a median reduction in seizure frequency of 27.7% compared to the preimplantation baseline, while the low-current stimulation group showed a median increase of 6.3%. This difference approached statistical significance. The entire population then received maximally tolerable stimulation. The high-current stimulation group showed a further 14.3% reduction, while the low-current stimulation group showed a 25.4% reduction compared to the blinded period. The efficacy of vagus nerve stimulation seemed to depend on stimulus parameters, and a cumulative effect was evident. These results are encouraging, and further study of this modality as an adjunct treatment for epilepsy is warranted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effects of Vagal Stimulation on Experimentally Induced Seizures in Rats
Woodbury, D. M., & Woodbury, J. W. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05852.x · Cited by 369
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184
Cited by
Englot, D. J., Chang, E. F., & Auguste, K. I. (2011) · Journal of Neurosurgery · doi:10.3171/2011.7.jns11977 · Cited by 514
(2020) · Operative Techniques in Epilepsy Surgery · doi:10.1055/b-0040-177306 · Cited by 397
Schachter, S. C., & Saper, C. B. (1998) · Epilepsia · doi:10.1111/j.1528-1157.1998.tb01151.x · Cited by 348
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258
“Indications for VNS use in epilepsy include the following: partial and generalized idiopathic epilepsy, multifocal epilepsy, drop attacks (tonic/atonic seizures), generalized tonic–clonic seizures, Lennox-Gastaut syndrome, and tuberous sclerosis complex (TSC)–related multifocal epilepsy.(5,6,13,14) VNS may be an alter…”
BackgroundAmar, A. P., Heck, C. N., Levy, M. L., Thomas, S., DeGiorgio, C. M., Oviedo, S., & Apuzzo, M. L. J. (1998) · Neurosurgery · doi:10.1097/00006123-199812000-00001 · Cited by 164
Metadata
- Authors
- Landy, H. J., Ramsay, R. E., Slater, J., Casiano, R. R., & Morgan, R.
- Venue
- Journal of Neurosurgery
- Published
- 1993-01
- Volume
- 78
- Issue
- 1
- Pages
- 26-31
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2094837814
- Cited by
- 110
- References
- 2
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.