Abstract
Numerous methods have been pursued to evaluate function in central motor pathways during surgery in the anesthetized patient. At this time, no standard has emerged, possibly because each of the methods described to date requires some degree of compromise and/or lacks sensitivity. Object. The goal of this study was to develop and evaluate a protocol for intraoperative monitoring of spinal motor conduction that: 1) is safe; 2) is sensitive and specific to motor pathways; 3) provides immediate feedback; 4) is compatible with anesthesia requirements; 5) allows monitoring of spontaneous and/or nerve root stimulus—evoked electromyography; 6) requires little or no involvement of the surgical team; and 7) requires limited equipment beyond that routinely used for somatosensory evoked potential (SSEP) monitoring. Using a multipulse electrical stimulator designed for transcranial applications, the authors have developed a protocol that they term “threshold-level” multipulse transcranial electrical stimulation (TES). Methods. Patients considered at high risk for postoperative deficit were studied. After anesthesia had been induced and the patient positioned, but prior to incision, “baseline” measures of SSEPs were obtained as well as the minimum (that is, threshold-level) TES voltage needed to evoke a motor response from each of the muscles being monitored. A brief, high-frequency pulse train (three pulses; 2-msec interpulse interval) was used for TES in all cases. Data (latency and amplitude for SSEP; threshold voltage for TES) were collected at different times throughout the surgical procedure. Postoperative neurological status, as judged by evaluation of sensory and motor status, was compared with intraoperative SSEP and TES findings for determination of the sensitivity and specificity of each electrophysiological monitoring technique. Of the 34 patients enrolled, 32 demonstrated TES-evoked responses in muscles innervated at levels caudal to the lesion when examined after anesthesia induction and positioning but prior to incision (that is, baseline). In contrast, baseline SSEPs could be resolved in only 25 of the 34 patients. During surgery, significant changes in SSEP waveforms were noted in 12 of these 25 patients, and 10 patients demonstrated changes in TES thresholds. Fifteen patients experienced varying degrees and durations of postoperative neurological deficit. Intraoperative changes in TES thresholds accurately predicted each instance of postoperative motor weakness without error, but failed to predict four instances of postoperative sensory deficit. Intraoperative SSEP monitoring was not 100% accurate in predicting postoperative sensory status and failed to predict five instances of postoperative motor deficit. As a result of intraoperative TES findings, the surgical plan was altered or otherwise influenced in six patients (roughly 15% of the sample population), possibly limiting the extent of postoperative motor deficit experienced by these patients. Conclusions. This novel method for intraoperative monitoring of spinal motor conduction appears to meet all of the goals outlined above. Although the risk of postoperative motor deficit is relatively low for the majority of spine surgeries (for example, a simple disc), high-risk procedures, such as tumor resection, correction of vascular abnormalities, and correction of major deformities, should benefit from the virtually immediate and accurate knowledge of spinal motor conduction provided by this new monitoring approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ROTHWELL, J. C., THOMPSON, P. D., DAY, B. L., DICK, J. P. R., KACHI, T., COWAN, J. M. A., & MARSDEN, C. D. (1987) · Brain · doi:10.1093/brain/110.5.1173 · Cited by 585
Pyramidal tract activity associated with a conditioned hand movement in the monkey.
Evarts, E. V. (1966) · Journal of Neurophysiology · doi:10.1152/jn.1966.29.6.1011 · Cited by 574
Barker, A. T., Freeston, I. L., Jalinous, R., & Jarratt, J. A. (1987) · Neurosurgery · doi:10.1097/00006123-198701000-00024 · Cited by 512
Variability of motor potentials evoked by transcranial magnetic stimulation
Kiers, L., Cros, D., Chiappa, K. H., & Fang, J. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90115-6 · Cited by 477
Safety of rapid-rate transcranial magnetic stimulation in normal volunteers
Pascual-Leone, A., Houser, C. M., Reese, K., Shotland, L. I., Grafman, J., Sato, S., Valls-Solé, J., Brasil-Neto, J. P., Wassermann, E. M., Cohen, L. G., et al. (1993) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(93)90094-6 · Cited by 408
Boyd, S. G., Rothwell, J. C., Cowan, J. M., Webb, P. J., Morley, T., Asselman, P., & Marsden, C. D. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.3.251 · Cited by 329
Corticospinal Neurones. Their Role in Movement
GILMAN, S. (1979) · Neurology · doi:10.1212/wnl.29.6.915-b · Cited by 273
The mode of activation of pyramidal tract cells by intracortical stimuli.
Jankowska, E., Padel, Y., & Tanaka, R. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011034 · Cited by 267
Burke, D., Hicks, R., Gandevia, S. C., Stephen, J., Woodforth, I., & Crawford, M. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019864 · Cited by 259
Kalkman, C. J., Drummond, J. C., Ribberink, A. A., Patel, P. M., Sano, T., & Bickford, R. G. (1992) · Anesthesiology · doi:10.1097/00000542-199204000-00003 · Cited by 227
Cited by
Datta, A., Bansal, V., Diaz, J., Patel, J., Reato, D., & Bikson, M. (2009) · Brain Stimulation · doi:10.1016/j.brs.2009.03.005 · Cited by 1,290
MacDonald, D. B., Skinner, S., Shils, J., & Yingling, C. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.07.025 · Cited by 568
Sala, F., Palandri, G., Basso, E., Lanteri, P., Deletis, V., Faccioli, F., & Bricolo, A. (2006) · Neurosurgery · doi:10.1227/01.neu.0000215948.97195.58 · Cited by 452
Intraoperative Motor Evoked Potential Monitoring: Overview and Update
MacDonald, D. B. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9033-0 · Cited by 348
Safety of Intraoperative Transcranial Electrical Stimulation Motor Evoked Potential Monitoring
MacDonald, D. B. (2002) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200210000-00005 · Cited by 342
Metadata
- Authors
- Calancie, B., Harris, W., Broton, J. G., Alexeeva, N., & Green, B. A.
- Venue
- Journal of Neurosurgery
- Published
- 1998-03
- Volume
- 88
- Issue
- 3
- Pages
- 457-470
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W2139673190
- Cited by
- 289
- References
- 21
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Threshold-level” multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring. https://app.cochat.ai/papers/10.3171/jns.1998.88.3.0457
- The paper
- Calancie, B., Harris, W., Broton, J. G., Alexeeva, N., & Green, B. A. (1998). “Threshold-level” multipulse transcranial electrical stimulation of motor cortex for intraoperative monitoring of spinal motor tracts: description of method and comparison to somatosensory evoked potential monitoring. Journal of Neurosurgery. https://doi.org/10.3171/jns.1998.88.3.0457
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.