The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Cerebral perfusion pressure in head-injured patients: a noninvasive assessment using transcranial Doppler ultrasonography
Abstract
Object. The authors studied the reliability of a new method for noninvasive assessment of cerebral perfusion pressure (CPP) in head-injured patients in which mean arterial blood pressure (ABP) and transcranial Doppler middle cerebral artery mean and diastolic flow velocities are measured. Methods. Cerebral perfusion pressure was estimated (eCPP) over periods of continuous monitoring (20 minutes—2 hours, 421 daily examinations) in 96 head-injured patients (Glasgow Coma Scale score < 13) who were admitted to the intensive care unit. All patients were sedated, paralyzed, and ventilated. The eCPP and the measured CPP (ABP minus intracranial pressure, measured using an intraparenchymal microsensor) were compared. The correlation between eCPP and measured CPP was r = 0.73; p < 10−6. In 71% of the examinations, the estimation error was less than 10 mm Hg and in 84% of the examinations, the error was less than 15 mm Hg. The method had a high positive predictive power (94%) for detecting low CPP (< 60 mm Hg). The eCPP also accurately reflected changes in measured CPP over time (r > 0.8; p < 0.001) in situations such as plateau and B waves of intracranial pressure, arterial hypotension, and refractory intracranial hypertension. A good correlation was found between the average measured CPP and eCPP when day-by-day variability was assessed in a group of 41 patients (r = 0.71). Conclusions. Noninvasive estimation of CPP by using transcranial Doppler ultrasonography may be of value in situations in which monitoring relative changes in CPP is required without invasive measurement of intracranial pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Recipes--The Art of Scientific Computing.
Fritsch, F. N., Press, W. H., Flannery, B. P., Teukolsky, S. A., & Vetterling, W. T. (1988) · Mathematics of Computation · doi:10.2307/2007938 · Cited by 4,845
Cerebral perfusion pressure: management protocol and clinical results
Rosner, M. J., Rosner, S. D., & Johnson, A. H. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.6.0949 · Cited by 963
Impact of ICP instability and hypotension on outcome in patients with severe head trauma
Marmarou, A., Anderson, R. L., Ward, J. D., Choi, S. C., Young, H. F., Eisenberg, H. M., Foulkes, M. A., Marshall, L. F., & Jane, J. A. (1991) · Journal of Neurosurgery · doi:10.3171/sup.1991.75.1s.0s59 · Cited by 819
Chan, K.-H., Miller, J. D., Dearden, N. M., Andrews, P. J. D., & Midgley, S. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.1.0055 · Cited by 397
Autoregulation and CO2 responses of cerebral blood flow in patients with acute severe head injury
Enevoldsen, E. M., & Jensen, F. T. (1978) · Journal of Neurosurgery · doi:10.3171/jns.1978.48.5.0689 · Cited by 334
Role of pressure gradients and bulk flow in dynamics of vasogenic brain edema
Reulen, H. J., Graham, R., Spatz, M., & Klatzo, I. (1977) · Journal of Neurosurgery · doi:10.3171/jns.1977.46.1.0024 · Cited by 327
Czosnyka, M., Richards, H. K., Whitehouse, H. E., & Pickard, J. D. (1996) · Journal of Neurosurgery · doi:10.3171/jns.1996.84.1.0079 · Cited by 208
Self-citationSecondary insults to the injured brain.
Jd, M., & Dp, B. (1982) · PubMed · Cited by 202
Secondary brain insults after head injury: clinical perspectives.
Chesnut, R. M. (1995) · PubMed · Cited by 173
Evaluation of intracranial pressure from transcranial Doppler studies in cerebral disease
Klingelh�fer, J., Conrad, B., Benecke, R., Sander, D., & Markakis, E. (1988) · Journal of Neurology · doi:10.1007/bf00314307 · Cited by 165
Enevoldsen, E. M., Cold, G., Taagehøj Jensen, F., & Malmros, R. (1976) · Journal of Neurosurgery · doi:10.3171/jns.1976.44.2.0191 · Cited by 164
永井, 肇., Kamiya, K., & 石井, 昌. (1994) · Springer eBooks · Cited by 152
Mean intracranial pressure monitoring by a non-invasive audiological technique: a pilot study.
Reid, A., Marchbanks, R. J., Bateman, D. E., Martin, A. M., Brightwell, A. P., & Pickard, J. D. (1989) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.52.5.610 · Cited by 76
Self-citationSystematic overestimation of intracranial pressure measured using a Camino pressure monitor.
Czosnyka, M., Harland, S. P., Piechnik, S. K., Kirkpatrick, P. J., Czosnyka, Z. H., & Menon, D. K. (1996) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.61.4.427 · Cited by 7
Self-citation
Cited by
Monitoring and interpretation of intracranial pressure
Czosnyka, M. (2004) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2003.033126 · Cited by 794
Self-citationTranscranial Doppler sonography pulsatility index (PI) reflects intracranial pressure (ICP)
Bellner, J., Romner, B., Reinstrup, P., Kristiansson, K.-A., Ryding, E., & Brandt, L. (2004) · Surgical Neurology · doi:10.1016/j.surneu.2003.12.007 · Cited by 527
Monitoring the injured brain: ICP and CBF
Steiner, L. A., & Andrews, P. J. D. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael110 · Cited by 400
Monitoring Intracranial Pressure in Traumatic Brain Injury
Smith, M. (2008) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000297296.52006.8e · Cited by 294
Risdall, J. E., & Menon, D. K. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0230 · Cited by 185
Metadata
- Authors
- Czosnyka, M., Matta, B. F., Smielewski, P., Kirkpatrick, P. J., & Pickard, J. D.
- Venue
- Journal of Neurosurgery
- Published
- 1998-05
- Volume
- 88
- Issue
- 5
- Pages
- 802-808
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2017968594
- Cited by
- 285
- References
- 14
- FWCI
- 4.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.