The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment
Open accessAbstract
BACKGROUND AND PURPOSE: Flow-diverting approaches to intracranial aneurysm treatment had many promising early results, but recent apparently successful treatments have been complicated by later aneurysm hemorrhage. We analyzed 7 cases of aneurysms treated with flow diversion to explore the possible rupture mechanisms. MATERIALS AND METHODS: CFD analysis of pre- and posttreatment conditions was performed on 3 giant aneurysms that ruptured after treatment and 4 successfully treated aneurysms. Pre- and posttreatment hemodynamics were compared including WSS, relative blood flows, vascular resistances, and pressures, to identify the effects of flow-diverter placements. RESULTS: Expected reductions in aneurysm velocity and WSS were obtained, indicating effective flow diversion from the sac into the parent artery, consistent with periprocedural observations. In each case with postaneurysm rupture, the result of flow diversion led to an increase in pressure within the aneurysm. This pressure increase is related to larger effective resistance in the parent artery from placement of the devices and, in 2 cases, the reduction of a preaneurysm stenosis. CONCLUSIONS: Flow-diversion devices can cause intra-aneurysmal pressure increases, which can potentially lead to rupture, especially for giant aneurysms. This relates both to changes in the parent artery configuration, such as reduction of a proximal stenosis, and to the flow diversion into higher resistance parent artery pathways combined with cerebral autoregulation, leading to higher pressure gradients. These may be important effects that should be considered when planning interventions. Potentially dangerous cases could be identified with angiography and/or patient-specific CFD models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
Cebral, J. R., Castro, M. A., Appanaboyina, S., Putman, C. M., Millan, D., & Frangi, A. F. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.844159 · Cited by 545
Self-citationLylyk, P., Ferrario, A., Pabón, B., Miranda, C., & Doroszuk, G. (2005) · Journal of Neurosurgery · doi:10.3171/jns.2005.102.2.0235 · Cited by 211
Self-citationFlow–area relationship in internal carotid and vertebral arteries
Cebral, J. R., Castro, M. A., Putman, C. M., & Alperin, N. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/5/005 · Cited by 158
Self-citationCebral, J. R., & Löhner, R. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2005.844172 · Cited by 136
Self-citationAppanaboyina, S., Mut, F., Löhner, R., Putman, C. M., & Cebral, J. R. (2007) · International Journal for Numerical Methods in Fluids · doi:10.1002/fld.1590 · Cited by 98
Self-citation
Cited by
Fischer, S., Vajda, Z., Aguilar Perez, M., Schmid, E., Hopf, N., Bäzner, H., & Henkes, H. (2012) · Neuroradiology · doi:10.1007/s00234-011-0948-x · Cited by 393
Saatci, I., Yavuz, K., Ozer, C., Geyik, S., & Cekirge, H. S. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3246 · Cited by 368
Endovascular Treatment of Intracranial Aneurysms: Current Status
Pierot, L., & Wakhloo, A. K. (2013) · Stroke · doi:10.1161/strokeaha.113.000733 · Cited by 289
Multiple aneurysms anatomy challenge 2018 (MATCH): phase I: segmentation
Berg, P., Voß, S., Saalfeld, S., Janiga, G., Bergersen, A. W., Valen-Sendstad, K., Bruening, J., Goubergrits, L., Spuler, A., Cancelliere, N. M., et al. (2018) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-018-00376-0 · Cited by 79
Cito, S., Geers, A. J., Arroyo, M. P., Palero, V. R., Pallarés, J., Vernet, A., Blasco, J., San Román, L., Fu, W., Qiao, A., et al. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1082-9 · Cited by 20
Metadata
- Authors
- Cebral, J. R., Mut, F., Raschi, M., Scrivano, E., Ceratto, R., Lylyk, P., & Putman, C. M.
- Venue
- American Journal of Neuroradiology
- Published
- 2010-11-11
- Volume
- 32
- Issue
- 1
- Pages
- 27-33
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2171531249
- Cited by
- 390
- References
- 6
- FWCI
- 16.67
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.