CoChat

Cerebral Microbleeds on MR Imaging: Comparison between 1.5 and 7T

Open access
Conijn, M.M.A., Geerlings, M.I., Biessels, G.-J., Takahara, T., Witkamp, T.D., Zwanenburg, J.J.M., Luijten, P.R., Hendrikse, J. · 2011 · American Journal of Neuroradiology
Cited by 99

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

BACKGROUND AND PURPOSE: The detection of microbleeds differs strongly between studies, due to differences in scan protocol. This study aims to compare the visualization of microbleeds with 3D T2*-weighted imaging at 1.5T with 3D dual-echo T2*-weighted imaging at 7T. MATERIALS AND METHODS: Thirty-four patients (29 male; mean age, 58 ± 12 years) with atherosclerotic disease from the Second Manifestations of ARTerial Disease study were included. 3D T2*-weighted imaging at 1.5T and dual-echo T2*-weighted imaging at 7T were done in all patients. The presence and number of definite microbleeds were recorded on minimal intensity projections. Inter- and intraobserver reliability was assessed with Cohen κ test and the ICC. The difference in presence and number of microbleeds was tested with the McNemar test and Wilcoxon signed rank test. RESULTS: The interobserver ICC at 7T was 0.61 and the intraobserver ICC was 0.94, whereas at 1.5T the interobserver ICC was 0.50 and the intraobserver ICC was 0.59. Microbleeds were detected in significantly more patients on 7T (50%) than on 1.5T scans (21%) (P = .001). The number of microbleeds was also higher at 7T (median, 0.5; range, 0-5) than on 1.5T (median, 0.0; range, 0-6) (P = .002). CONCLUSIONS: 3D dual-echo T2*-weighted imaging at 7T results in better and more reliable detection of microbleeds compared with 3D T2*-weighted imaging at 1.5T.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3174/ajnr.a2450

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 99

Metadata

Authors
Conijn, M. M. A., Geerlings, M. I., Biessels, G.-J., Takahara, T., Witkamp, T. D., Zwanenburg, J. J. M., Luijten, P. R., & Hendrikse, J.
Venue
American Journal of Neuroradiology
Published
2011-05-05
Volume
32
Issue
6
Pages
1043-1049
ISSN
  • 0195-6108 (ISSN-L)
  • 1936-959X
OpenAlex
W2165524578
Cited by
99
References
7
FWCI
8.04
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Cerebral Microbleeds on MR Imaging: Comparison between 1.5 and 7T. https://app.cochat.ai/papers/10.3174/ajnr.a2450
The paper
Conijn, M. M. A., Geerlings, M. I., Biessels, G.-J., Takahara, T., Witkamp, T. D., Zwanenburg, J. J. M., Luijten, P. R., & Hendrikse, J. (2011). Cerebral Microbleeds on MR Imaging: Comparison between 1.5 and 7T. American Journal of Neuroradiology. https://doi.org/10.3174/ajnr.a2450

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.