Skeletal Muscle Quantitative Nuclear Magnetic Resonance Imaging and Spectroscopy as an Outcome Measure for Clinical Trials
Open accessThe DOI matches its Crossref record; 293 of the 293 references it cites were found in a registry or an index.
Abstract
Recent years have seen tremendous progress towards therapy of many previously incurable neuromuscular diseases. This new context has acted as a driving force for the development of novel non-invasive outcome measures. These can be organized in three main categories: functional tools, fluid biomarkers and imagery. In the latest category, nuclear magnetic resonance imaging (NMRI) offers a considerable range of possibilities for the characterization of skeletal muscle composition, function and metabolism. Nowadays, three NMR outcome measures are frequently integrated in clinical research protocols. They are: 1/ the muscle cross sectional area or volume, 2/ the percentage of intramuscular fat and 3/ the muscle water T2, which quantity muscle trophicity, chronic fatty degenerative changes and oedema (or more broadly, “disease activity”), respectively. A fourth biomarker, the contractile tissue volume is easily derived from the first two ones. The fat fraction maps most often acquired with Dixon sequences have proven their capability to detect small changes in muscle composition and have repeatedly shown superior sensitivity over standard functional evaluation. This outcome measure will more than likely be the first of the series to be validated as an endpoint by regulatory agencies. The versatility of contrast generated by NMR has opened many additional possibilities for characterization of the skeletal muscle and will result in the proposal of more NMR biomarkers. Ultra-short TE (UTE) sequences, late gadolinium enhancement and NMR elastography are being investigated as candidates to evaluate skeletal muscle interstitial fibrosis. Many options exist to measure muscle perfusion and oxygenation by NMR. Diffusion NMR as well as texture analysis algorithms could generate complementary information on muscle organization at microscopic and mesoscopic scales, respectively. 31 P NMR spectroscopy is the reference technique to assess muscle energetics non-invasively during and after exercise. In dystrophic muscle, 31 P NMR spectrum at rest is profoundly perturbed, and several resonances inform on cell membrane integrity. Considerable efforts are being directed towards acceleration of image acquisitions using a variety of approaches, from the extraction of fat content and water T2 maps from one single acquisition to partial matrices acquisition schemes. Spectacular decreases in examination time are expected in the near future. They will reinforce the attractiveness of NMR outcome measures and will further facilitate their integration in clinical research trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Precise measurement of muscle72 cell lipid content can be achieved through 1H magnetic resonance spectroscopy (1H MRS).73”
From Imaging of Sarcopenia in Type 2 Diabetes Mellitus (2024) · cites this paper as [72]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Brain magnetic resonance imaging with contrast dependent on blood oxygenation.
Ogawa, S., Lee, T. M., Kay, A. R., & Tank, D. W. (1990) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.87.24.9868 · Cited by 6,483
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“The ability to assess displacement of water protons in vitro and in vivo using diffusion-sensitizing pulsed-field gradients has motivated its use to probe microstructural information beyond the resolution of conventional NMR imaging, i.e. in the range of several microns.”
BackgroundGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“The ability to assess displacement of water protons in vitro and in vivo using diffusion-sensitizing pulsed-field gradients has motivated its use to probe microstructural information beyond the resolution of conventional NMR imaging, i.e. in the range of several microns.”
BackgroundCellular and molecular mechanisms of fibrosis
Wynn, T. (2008) · The Journal of Pathology · doi:10.1002/path.2277 · Cited by 4,495
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Lustig, M., Donoho, D. L., Santos, J. M., & Pauly, J. M. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914728 · Cited by 2,246 · cited 1×
“The ability to assess displacement of water protons in vitro and in vivo using diffusion-sensitizing pulsed-field gradients has motivated its use to probe microstructural information beyond the resolution of conventional NMR imaging, i.e. in the range of several microns.”
BackgroundStrimbu, K., & Tavel, J. A. (2010) · Current Opinion in HIV and AIDS · doi:10.1097/coh.0b013e32833ed177 · Cited by 2,062 · cited 1×
“∗Correspondence to: P.G. Carlier, Institut de Myologie and CEA, DSV, I2BM, MIRCen, Laboratoire de RMN, Pitie- Salpetriere University Hospital, Bd de l’Hôpital, 75651 Paris Cedex 13, France.”
Background
Research works printed but not linked: 2
- Rooney WD, Pollaro JR, Forbes SC, et al Application of the Extended Phas e Graph Technique to Improve T2 Quantitation Across Sites. 2011 In: Proceedings ISMRM 5419.
- Wary C, Azzabou N, Giraudeau C, et al Quantitative NMRI and NMRS identify augmented disease progression after loss of ambulation in forearms of boys with Duchenne muscular dystrophy. NMR Biomed. 2015 b; 28: 1150– 62. 26215733 · DOI
Cited by
MR biomarkers predict clinical function in Duchenne muscular dystrophy
Barnard, A. M., Willcocks, R. J., Triplett, W. T., Forbes, S. C., Daniels, M. J., Chakraborty, S., Lott, D. J., Senesac, C., Finanger, E. L., Harrington, A. T., et al. (2020) · Neurology · doi:10.1212/wnl.0000000000009012 · Cited by 99
“Skeletal muscle MRI and magnetic resonance (MR) spectroscopy (MRS) measures are noninvasive biomarkers that are sensitive to pathologic changes in dystrophic muscles, and MR biomarkers have the potential to serve as clinical trial endpoints.(6,7) Muscle MRI transverse magnetization relaxation time constant (T2) is alt…”
BackgroundMRI in Neuromuscular Diseases: An Emerging Diagnostic Tool and Biomarker for Prognosis and Efficacy
Dahlqvist, J. R., Widholm, P., Leinhard, O. D., & Vissing, J. (2020) · Annals of Neurology · doi:10.1002/ana.25804 · Cited by 90
“In primary inflammatory myopathies, it can act as an indicator of disease activity.(6) STIR sequences cannot quantify level of edema.”
BackgroundMethodSchlaffke, L., Rehmann, R., Rohm, M., Otto, L. A. M., Luca, A. D., Burakiewicz, J., Baligand, C., Monte, J. R., den Harder, C., Hooijmans, M. T., et al. (2019) · NMR in Biomedicine · doi:10.1002/nbm.4119 · Cited by 90
“Therefore, changing from a standing to a lying position could cause a signal drop in the T2 time due to a change in muscle activity, which should, however, be a process lasting several minutes rather than one hour.(32) The decrease in water‐T2 time could also be a consequence of altered intramuscular perfusion resulti…”
BackgroundEngelke, K., Chaudry, O., Gast, L. V., Eldib, M., Wang, L., Larédo, J.-D., Schett, G. A., & Nagel, A. M. (2023) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2023.07.005 · Cited by 109
MR Imaging of Atraumatic Muscle Disorders
Smitaman, E. E., Flores, D. V., Gómez, C. M., & Pathria, M. N. (2018) · Radiographics · doi:10.1148/rg.2017170112 · Cited by 82
Metadata
- Authors
- Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D.
- Affiliations
- National Academy of Sciences of Belarus (BY)
- Commissariat à l'Énergie Atomique et aux Énergies Alternatives (FR)
- University of Bern (CH)
- Strasbourg University, CNRS, ICube, Strasbourg, France
- Consultants for Research in Imaging and Spectroscopy, Tournai, Belgium
- N.I. Prirogov Russian National Medical Research University, Clinical Research Institute of Pediatrics, Moscow, Russian Federation
- Corresponding author
- Carlier, Pierre G.
- Venue
- Journal of Neuromuscular Diseases
- Publisher
- SAGE Publications
- Published
- 2016-03-03
- Volume
- 3
- Issue
- 1
- Pages
- 1-28
- ISSN
- 2214-3599 (ISSN-L)
- 2214-3602
- PMC
- PMC5271435
- OpenAlex
- W2328069846
- Cited by
- 186
- References
- 292
- Citations by year
- 2026: 8 · 2025: 19 · 2024: 21 · 2023: 21 · 2022: 16 · 2021: 25 · 2020: 34 · 2019: 25 · 2018: 8 · 2017: 7
- FWCI
- 2.06
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Neuromuscular Diseases (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- HAL (submittedVersion, other-oa)
- Bern Open Repository and Information System (University of Bern) (submittedVersion, cc-by-nc)
- Open Access CRIS of the University of Bern
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- skeletal muscle, NMR spectroscopy, clinical trial outcome measures, neuromuscular disorders, Dixon sequence, muscle cross-sectional area, 31P NMR, muscle energetics, late gadolinium enhancement, interstitial fibrosis, diffusion NMR, texture analysis, muscle blood flow, plasma membrane integrity
- MeSH terms
- Clinical Trials as Topic, Humans, Magnetic Resonance Imaging, Neuromuscular Diseases, Outcome Assessment, Health Care, Muscle, Skeletal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.