Subthalamic nucleus deep brain stimulation in parkinson's disease: the effect of varying stimulation parameters
Open accessThe DOI matches its Crossref record; 51 of the 52 references it cites were found in a registry or an index.
Abstract
Subthalamic Nucleus Deep Brain Stimulation (STN DBS) is a well-established and effective treatment modality for selected patients with Parkinson’s disease (PD). Since its advent, systematic exploration of the effect of stimulation parameters including the stimulation intensity, frequency, and pulse width have been carried out to establish optimal therapeutic ranges. This review examines published data on these stimulation parameters in terms of efficacy of treatment and adverse effects. Altering stimulation intensity is the mainstay of titration in DBS programming via alterations in voltage or current settings, and is characterised by a lower efficacy threshold and a higher side effect threshold which define the therapeutic window. In addition, much work has been done in exploring the effects of frequency modulation, which may help patients with gait freezing and other axial symptoms. However, there is a paucity of data on the use of ultra-short pulse width settings which are now possible with technological advances. We also discuss current evidence for the use of novel programming techniques including directional and adaptive stimulation, and highlight areas for future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“all psychiatric DBS has used stimulation parameters designed for Parkinson disease, which may not be appropriate for a very different set of brain circuits and specifically may not engage the pathophysiology of psychiatric disease”
From Deep brain stimulation for psychiatric disorders: From focal brain targets to cognitive networks (2021) · cites this paper as Dayal et al. 2017
In the citing paper
“DBS parameters for MDD and OCD are largely derived from those used in Parkinson disease (Dayal et al. 2017).”
From Deep brain stimulation for psychiatric disorders: From focal brain targets to cognitive networks (2021) · cites this paper as Dayal et al. 2017
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Frequency Dependence of Signal Power and Spatial Reach of the Local Field Potential
Leski, S., Lindén, H., Tetzlaff, T., Pettersen, K. H., & Einevoll, G. T. (2013) · PubMed · doi:10.18154/rwth-conv-084442 · Cited by 3,639
Electrical Stimulation of the Subthalamic Nucleus in Advanced Parkinson's Disease
Limousin, P., Krack, P., Pollak, P., Benazzouz, A., Ardouin, C., Hoffmann, D., & Benabid, A.-L. (1998) · New England Journal of Medicine · doi:10.1056/nejm199810153391603 · Cited by 1,853
Self-citationWeaver, F. M. (2009) · JAMA · doi:10.1001/jama.2008.929 · Cited by 1,525
Effect on parkinsonian signs and symptoms of bilateral subthalamic nucleus stimulation
Limousin, P., Pollak, P., Benazzouz, A., Hoffmann, D., Le Bas, J.-F., Perret, J. E., Benabid, A.-L., & Broussolle, E. (1995) · The Lancet · doi:10.1016/s0140-6736(95)90062-4 · Cited by 1,392
Self-citationAdaptive deep brain stimulation in advanced Parkinson disease.
Little, S., Pogosyan, A., Neal, S., Zavala, B., Zrinzo, L., Hariz, M., Foltynie, T., Limousin, P., Ashkan, K., FitzGerald, J., et al. (2013) · Annals of Neurology · doi:10.1002/ana.23951 · Cited by 1,374 · cited 1×
“Not only was there more effective overall control of motor symptoms, but adaptive DBS seemed to have less than half the energy requirements of continuous stimulation by virtue of its intermittent nature [19].”
BackgroundSelf-citationKühn, A. A., Kupsch, A., Schneider, G., & Brown, P. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04717.x · Cited by 892
Stefani, A., Lozano, A. M., Peppe, A., Stanzione, P., Galati, S., Tropepi, D., Pierantozzi, M., Brusa, L., Scarnati, E., & Mazzone, P. (2007) · Brain · doi:10.1093/brain/awl346 · Cited by 807
Kühn, A. A., Tsui, A., Aziz, T., Ray, N., Brücke, C., Kupsch, A., Schneider, G.-H., & Brown, P. (2009) · Experimental Neurology · doi:10.1016/j.expneurol.2008.11.008 · Cited by 630
Weinberger, M., Mahant, N., Hutchison, W. D., Lozano, A. M., Moro, E., Hodaie, M., Lang, A. E., & Dostrovsky, J. O. (2006) · Journal of Neurophysiology · doi:10.1152/jn.00697.2006 · Cited by 588
The impact on Parkinson’s disease of electrical parameter settings in STN stimulation
Moro, E., Esselink, R. J. A., Xie, J., Hommel, M., Benabid, A. L., & Pollak, P. (2002) · Neurology · doi:10.1212/wnl.59.5.706 · Cited by 500 · cited 8×
“As well as these, stimulationinduced dyskinesias were observed in 5 of 12 patients, and foot dystonia in one of these [5].”
BackgroundResultInfluential
Cited by
Biomarkers for closed-loop deep brain stimulation in Parkinson disease and beyond
Bouthour, W., Mégevand, P., Donoghue, J., Lüscher, C., Birbaumer, N., & Krack, P. (2019) · Nature Reviews Neurology · doi:10.1038/s41582-019-0166-4 · Cited by 230
An update on adaptive deep brain stimulation in Parkinson's disease
Habets, J. G. V., Heijmans, M., Kuijf, M. L., Janssen, M. L. F., Temel, Y., & Kubben, P. L. (2018) · Movement Disorders · doi:10.1002/mds.115 · Cited by 169
Yogev, D., Goldberg, T., Arami, A., Tejman‐Yarden, S., Winkler, T. E., & Maoz, B. M. (2023) · APL Bioengineering · doi:10.1063/5.0152290 · Cited by 164
Deep brain stimulation for psychiatric disorders: From focal brain targets to cognitive networks
Sullivan, C. R. P., Olsen, S., & Widge, A. S. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2020.117515 · Cited by 112
Deep brain stimulation: a review of the open neural engineering challenges
Vissani, M., Isaias, I. U., & Mazzoni, A. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/abb581 · Cited by 81
“[13] Dayal V, Limousin P and Foltynie T 2017 Subthalamic nucleus deep brain stimulation in parkinson’s disease: the effect of varying stimulation parameters J.”
BackgroundPulse duration settings in subthalamic stimulation for Parkinson's disease
Steigerwald, F., Timmermann, L., Kühn, A. A., Schnitzler, A., Reich, M. M., Kirsch, A. D., Barbe, M. T., Visser-Vandewalle, V. E. R. M., Hübl, J., van Riesen, C., et al. (2017) · Movement Disorders · doi:10.1002/mds.27238 · Cited by 59
“In DBS therapy, amplitude, pulse width, and frequency settings are adjusted in each patient individually, starting with standard values, to achieve the maximum reduction of clinical signs with minimal side effects and energy consumption.(6) We have demonstrated here that standard programming settings used in STN-DBS f…”
BackgroundMethodAdam, E. M., Brown, E. N., Kopell, N., & McCarthy, M. M. (2022) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2120808119 · Cited by 56
Wang, S., Zhu, G., Shi, L., Zhang, C., Wu, B., Yang, A., Meng, F., Jiang, Y., & Zhang, J. (2023) · Journal of Parkinson s Disease · doi:10.3233/jpd-225053 · Cited by 59
“However, the design of cDBS has inherent limitations, including various stimulation-induced adverse effects, such as dysarthria and imbalance [12, 15, 16], increased battery consumption [13, 14], and frequent parameter adjustments during follow-up to address symptom changes [17].”
BackgroundCarmichael, K., Evans, R. C., Lopez, E., Sun, L., Kumar, M., Ding, J., Khaliq, Z. M., & Cai, H. (2021) · Frontiers in Neural Circuits · doi:10.3389/fncir.2021.644776 · Cited by 59
Rodríguez‐Rojas, R., Pineda‐Pardo, J. A., Máñez-Miró, J. U., Sanchez‐Turel, A., Martínez‐Fernández, R., del Álamo, M., DeLong, M. R., & Obeso, J. A. (2021) · Movement Disorders · doi:10.1002/mds.28862 · Cited by 43
Thalamic short pulse stimulation diminishes adverse effects in essential tremor patients
Choe, C., Hidding, U., Schaper, M., Gulberti, A., Köppen, J. A., Buhmann, C., Gerloff, C. P., Moll, C. K. E., Hamel, W., & Pötter‐Nerger, M. (2018) · Neurology · doi:10.1212/wnl.0000000000006033 · Cited by 43
“All included patients were treated with bilateral DBS. Baseline characteristics are summarized in table 1.”
BackgroundInfluentialBusch, J. L., Kaplan, J., Behnke, J. K., Witzig, V. S., Drescher, L. K., Habets, J., & Kühn, A. A. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-01124-7 · Cited by 45
“This may potentially lead to overtreatment resulting in dyskinesia or undertreatment with worsened bradykinesia 2 .”
Busch, J. L., Kaplan, J., Habets, J., Feldmann, L. K., Roediger, J., Köhler, R. M., Merk, T., Faust, K., Schneider, G., Bergman, H., et al. (2024) · Brain stimulation · doi:10.1016/j.brs.2024.01.007 · Cited by 40
An, Q., Yin, Z., Ma, R., Fan, H., Xu, Y., Gan, Y., Gao, Y., Meng, F., Yang, A., Jiang, Y., et al. (2022) · Journal of Neurology · doi:10.1007/s00415-022-11495-z · Cited by 42
“Much work has been done to explore the effects of the cDBS stimulation parameters in PD patients, including the intensity, frequency and pulse width [61].”
BackgroundXu, W., Wang, J., Li, X.-N., Liang, J., Song, L., Wu, Y., Liu, Z., Sun, B., & Li, W. (2023) · Translational Neurodegeneration · doi:10.1186/s40035-023-00390-w · Cited by 39
“It is worth noting that dyskinesia can emerge as a side effect of HFS in humans [186], and similar effects have been demonstrated in mice that HFS, alongside increased pulse width and current, can lead to severe dyskinesia in vivo [187].”
BackgroundDayal, V., Grover, T., Limousin, P. D., Akram, H., Cappon, D., Candelario, J., Salazar, M., Tripoliti, E., Zrinzo, L. U., Hyam, J. A., et al. (2018) · Journal of Parkinson s Disease · doi:10.3233/jpd-171272 · Cited by 39
Self-citationLateralized effects of deep brain stimulation in Parkinson’s disease: evidence and controversies
Lin, Z., Zhang, C., Li, D., & Sun, B. (2021) · npj Parkinson s Disease · doi:10.1038/s41531-021-00209-3 · Cited by 39
Therapeutic Strategies to Treat or Prevent Off Episodes in Adults with Parkinson’s Disease
Vijiaratnam, N., & Foltynie, T. (2020) · Drugs · doi:10.1007/s40265-020-01310-2 · Cited by 36
Self-citationBouthour, W., Wegrzyk, J., Momjian, S., Péron, J., Fleury, V., Tomkova, E., Horvath, J. E., Boëx, C., Lüscher, C., Burkhard, P. R., et al. (2017) · Movement Disorders · doi:10.1002/mds.27265 · Cited by 34
Multiple stimulation parameters influence efficacy of deep brain stimulation in parkinsonian mice
Schor, J. S., & Nelson, A. (2019) · Journal of Clinical Investigation · doi:10.1172/jci122390 · Cited by 34
“Despite several decades of clinical experience, however, the underlying mechanisms and ideal therapeutic parameters for STN DBS remain unclear (4).”
BackgroundAssmann, R., Douven, P., Kleijnen, J., van Koeveringe, G. A., Joosten, E. A. J., Melenhorst, J., & Breukink, S. O. (2020) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13255 · Cited by 32
Cassara, A. M., Newton, T., Zhuang, K., Regel, S. J., Achermann, P., Pascual‐Leone, Á., Kuster, N., & Neufeld, E. (2025) · Bioelectromagnetics · doi:10.1002/bem.22536 · Cited by 34
Novel Programming Features Help Alleviate Subthalamic Nucleus Stimulation‐Induced Side Effects
Dayal, V., de Roquemaurel, A., Grover, T., Ferreira, F., Salazar, M., Milabo, C., Candelario, J., Zrinzo, L. U., Akram, H., Limousin, P. D., et al. (2020) · Movement Disorders · doi:10.1002/mds.28252 · Cited by 30
“high amplitudes and PWs, which constitute the amount of charge per pulse, are associated with the development of adverse effects.(4,9,38) The further improvement in adverse effects seen with the use of short PW may therefore be due, at least in part, to lower electrical charge used per pulse of stimulation.”
BackgroundSelf-citationRijn, E. M. D.-V., Provenza, N. R., Calvert, J. S., Gilron, R., Allawala, A. B., Darie, R., Syed, S. H., Matteson, E., Vogt, G. S., Avendaño-Ortega, M., et al. (2020) · Cell Reports Methods · doi:10.1016/j.crmeth.2021.100010 · Cited by 31
“Stimulation frequencies over 125 Hz are clinically relevant for PD, OCD, TRD, and pain (Dayal et al., 2017; Miller et al., 2016; Ramasubbu et al., 2018).”
BackgroundIneichen, C., Shepherd, N. R., & Sürücü, O. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00468 · Cited by 29
Troubleshooting Gait Disturbances in Parkinson’s Disease With Deep Brain Stimulation
Pozzi, N. G., Palmisano, C., Reich, M. M., Capetian, P., Pacchetti, C., Volkmann, J., & Isaias, I. U. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.806513 · Cited by 29
Dyskinesia‐inducing lead contacts optimize outcome of subthalamic stimulation in Parkinson's disease
Bouthour, W., Béreau, M., Kibleur, A., Zacharia, A., Tomkova, E., Fleury, V., Benis, D., Momjian, S., Bally, J. F., Lüscher, C., et al. (2019) · Movement Disorders · doi:10.1002/mds.27853 · Cited by 26
Azgomi, H. F., Louie, K. H., Bath, J., Presbrey, K. N., Balakid, J. P., Marks, J. H., Wozny, T. A., Galifianakis, N. B., Luciano, M. S., Little, S. J., et al. (2025) · npj Parkinson s Disease · doi:10.1038/s41531-025-00990-5 · Cited by 27
“This is because of the extensive parameter space (i.e., amplitude, frequency, and pulse width of the stimulation impulses at each contact); identifying optimal gait settings would place an impractical demand on both time and resourcesforpatientsandclinicians 34,35 .”
Li, H., Liang, S., Yu, Y., Wang, Y., Cheng, Y., Yang, H., & Tong, X. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238936 · Cited by 24
“In principle, the best clinical symptom improvement is obtained with the minimum stimulation intensity [3].”
BackgroundBiophysical Principles and Computational Modeling of Deep Brain Stimulation
Ng, P. R., Bush, A., Vissani, M., McIntyre, C. C., & Richardson, R. M. (2023) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2023.04.471 · Cited by 29
Dementia associated with disorders of the basal ganglia
Vitanova, K. S., Stringer, K. M., Benítez, D. P., Brenton, J., & Cummings, D. M. (2019) · Journal of Neuroscience Research · doi:10.1002/jnr.24508 · Cited by 25
Aubignat, M., Lefranc, M., Tir, M., & Krystkowiak, P. C. (2020) · Revue Neurologique · doi:10.1016/j.neurol.2020.02.009 · Cited by 22
Cassara, A. M., Newton, T., Zhuang, K., Regel, S. J., Achermann, P., Pascual‐Leone, Á., Kuster, N., & Neufeld, E. (2025) · Bioelectromagnetics · doi:10.1002/bem.22542 · Cited by 23
Luo, B., Lu, Y., Qiu, C., Dong, W., Xue, C., Zhang, L., Liu, W., & Zhang, W. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.699010 · Cited by 20
“DBS has emerged as an effective surgical treatment for Parkinson’s disease (PD) (Miocinovic et al., 2013; Dayal et al., 2017; Habets et al., 2018).”
BackgroundPiña‐Fuentes, D., Beudel, M., Little, S. J., Brown, P., Oterdoom, D. L. M., & van Dijk, J. M. C. (2019) · BMJ Open · doi:10.1136/bmjopen-2019-029652 · Cited by 22
“Pulses are delivered at 130 Hz with a pulse width of 60 μs (standard clinical parameters) using a ramping period of 250 ms at onset and offset in order to help limit the presence of paraesthesias, autonomic or other non-specific side effects, such as dizziness or nausea.(25) From the four contacts available for each e…”
MethodKalampokini, S., Lyros, E., Lochner, P., Fassbender, K. C., & Unger, M. M. (2020) · Behavioural Neurology · doi:10.1155/2020/4329297 · Cited by 19
“Additionally, contact configuration (bipolar or monopolar) and stimulation parameters, including frequency, pulse width, and especially stimulation intensity, varied between patients among studies resulting in the variable volume of nucleus tissue stimulated and thus variable nonmotor and emotional effects [73, 74].”
BackgroundZheng, L., Feng, Z., Hu, H., Wang, Z., Yuan, Y., & Wei, X. F. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00397 · Cited by 17
Parameters for subthalamic deep brain stimulation in patients with dystonia: a systematic review
Wang, Y., Zhang, C., Sun, B., Li, D., & Wu, Y. (2021) · Journal of Neurology · doi:10.1007/s00415-020-10372-x · Cited by 17
Closing the loop of DBS using the beta oscillations in cortex
Liu, C., Zhao, G., Meng, Z., Zhou, C., Zhu, X., Zhang, W., Wang, J., Li, H., Wu, H., Fietkiewicz, C., et al. (2021) · Cognitive Neurodynamics · doi:10.1007/s11571-021-09690-1 · Cited by 19
McComish, S. F., Copas, A. N. M., & Caldwell, M. A. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.851058 · Cited by 17
Qin, G., Xie, H., Shi, L., Zhao, B., Gan, Y., Yin, Z., Xu, Y., Zhang, X., Chen, Y., Jiang, Y., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1228711 · Cited by 16
“, 2021), while a high frequency of 130 Hz was utilized as it is the most commonly used parameter for improving motor symptoms in clinical practice (Moro et al., 2002; Dayal et al., 2017).”
MethodWang, X., Du, J., Wang, D., Xu, C., Ren, Z., Wang, Y., Li, Y., Yu, T., & Ren, L. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2019.12.43 · Cited by 16
Spiliotis, K., Starke, J., Franz, D., Richter, A., & Köhling, R. (2021) · Biological Cybernetics · doi:10.1007/s00422-021-00909-2 · Cited by 18
“In addition, one can argue that our modelling study does not fully replicate clinical findings, which show that at frequencies > 185 Hz, side effects like dyskinesias seem to become more problematic (Dayal et al. 2017; Karl et al. 2019).”
BackgroundHow Human Single-Neuron Recordings Can Help Us Understand Cognition: Insights from Memory Studies
Kubska, Z. R., & Kamiński, J. (2021) · Brain Sciences · doi:10.3390/brainsci11040443 · Cited by 17
Hsieh, T.-H., He, X., Liu, H.-H., Chen, J. J., Peng, C., Liu, H., Rotenberg, A., Chen, K., Chang, M., Chiang, Y. H., et al. (2021) · Neural Plasticity · doi:10.1155/2021/1763533 · Cited by 15
Munoz, M. J., Goelz, L. C., Pal, G. D., Karl, J. A., Metman, L. V., Sani, S., Rosenow, J. M., Ciolino, J. D., Kurani, A. S., Corcos, D. M., et al. (2021) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.13476 · Cited by 13
Lellis, C. D. A., Herbas, M. A. M., & da Silva, L. J. (2024) · Einstein (São Paulo) · doi:10.31744/einstein_journal/2024rw0182 · Cited by 13
Human subthalamic nucleus neurons differentially encode speech and limb movement
Johari, K., Kelley, R. M., Tjaden, K., Patterson, C. G., Rohl, A., Berger, J. I., Corcos, D. M., & Greenlee, J. D. W. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.962909 · Cited by 12
“Previous reports on STN-DBS-induced speech impairment have investigated the effect of stimulation parameters (Tornqvist et al., 2005; Dayal et al., 2017; Knowles et al., 2018), stimulation-on vs.”
BackgroundDevaluez, M., Tir, M., Krystkowiak, P. C., Aubignat, M., & Lefranc, M. (2020) · Journal of neurosurgery · doi:10.3171/2020.6.jns192157 · Cited by 12
Kumar, G., Asthana, P., Yung, W., Kwan, K. M., Tin, C., & Ma, C. H. E. (2022) · Molecular Neurobiology · doi:10.1007/s12035-022-02872-w · Cited by 12
“The second-best DBS parameters (100 μA/130 Hz/60 μs) have been used in conventional DBS of PD patients [42, 43].”
MethodSomma, T., Esposito, F., Scala, M. R., Scelzo, A., Baiano, C., Patti, S., Meglio, V., Iasevoli, F., Cavallo, L. M., Solari, D., et al. (2022) · Journal of Personalized Medicine · doi:10.3390/jpm12101643 · Cited by 11
“in their review [51] analyzed the side effects emerging as a result of a change in the stimulation parameters delivered through a DBS contact.”
BackgroundTunable magnetic skyrmions in spintronic nanostructures for cellular-level magnetic neurostimulation
Saha, R., Wu, K., Su, D., & Wang, J.-P. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab39a7 · Cited by 11
The utility of deep brain stimulation surgery for treating eating disorders: A systematic review
Potes, M. I., Joaquin, C., Wiecks, N., Phan, S., & Hassan, O. (2021) · Surgical Neurology International · doi:10.25259/sni_730_2020 · Cited by 10
“[37] Adjustable stimulation parameters include voltage, pulse width, frequency, specific coordinates, and number of electrodes, which may be adjusted to optimize success of the procedure.[9]”
BackgroundSystematic Evaluation of DBS Parameters in the Hemi-Parkinsonian Rat Model
Mottaghi, S., Buchholz, O., & Hofmann, U. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.561008 · Cited by 12
Hidding, U., Schaper, M., Gulberti, A., Buhmann, C., Gerloff, C. P., Moll, C. K. E., Hamel, W., Choe, C., & Pötter‐Nerger, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-11291-9 · Cited by 11
Dharnipragada, R., Denduluri, L. S., Naik, A., Bertogliat, M. J., Awad, M., Ikramuddin, S. S., & Park, M. C. (2023) · Parkinsonism & Related Disorders · doi:10.1016/j.parkreldis.2023.105809 · Cited by 9
Değirmenci, Y. (2023) · Deep Brain Stimulation · doi:10.1016/j.jdbs.2023.12.002 · Cited by 9
Hsieh, T.-H., Chu, P.-C., Nguyen, T. X. D., Kuo, C.-W., Chang, P.-K., Chen, K.-H. S., & Liu, H. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25115687 · Cited by 9
“Moreover, deep brain stimulation (DBS) in the subthalamic nucleus (STN) is an established treatment for patients with advanced Parkinson’s Disease (PD) [47,48].”
BackgroundInggas, M. A. M., Coyne, T. J., Taira, T., Karsten, J. A., Patel, U., Kataria, S., Putra, A. W., Setiawan, J., Tanuwijaya, A. W., Wong, E., et al. (2024) · Neurosurgical Review · doi:10.1007/s10143-024-03010-x · Cited by 10
“1 PRISMA diagram showing a total of 14 studies included in the review from 487 initial studies extracted from various medical database imaging modalities, the utilization of patient-specific anatomical models, and the incorporation of single-cell recording of the STN [5, 8].”
Alterations of resting-state networks of Parkinson‘s disease patients after subthalamic DBS surgery
Sure, M., Mertiens, S., Vesper, J., Schnitzler, A., & Florin, E. (2023) · NeuroImage Clinical · doi:10.1016/j.nicl.2023.103317 · Cited by 11
“In a further step, stimulation parameter-dependent side effects (Dayal et al., 2017; Hartmann et al., 2019) could be optimally linked to RSN changes induced by DBS electrode implantation.”
Lu, J., Feng, Z., Shi, X., Jiang, L., & Hao, Y. (2020) · Journal of Neurorestoratology · doi:10.26599/jnr.2019.9040018 · Cited by 8
“Moreover, 2 patients exhibited improvement in short-term nonmotor symptoms owing to voltage lowering and stimulation site adjustment [6].”
BackgroundMulti-Disease Deep Brain Stimulation
Parastarfeizabadi, M., Sillitoe, R. V., & Kouzani, A. Z. (2020) · IEEE Access · doi:10.1109/access.2020.3041942 · Cited by 8
“Different stimulation parameters have been reported in the literature for treatment of epilepsy [59], depression [60], and PD [61] conditions.”
BackgroundMei, J., Chang, B., Xiong, C., Jiang, M., & Niu, C. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.916658 · Cited by 8
Wu, K., Su, D., Saha, R., & Wang, J. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b07542 · Cited by 8
“ues vary from 20 µs to 120 µs while higher pulse width values require lower stimulus intensities to achieve a required clinical effect, and the stimulus pulse frequency varies from 60 Hz up to 200 Hz [1]. The size of SOTNS can be down to tens of nanometers, thus, arrays of SOTNSs could be fabricated and integrated tog…”
BackgroundKleinholdermann, U., Bacara, B., Timmermann, L., & Pedrosa, D. J. (2022) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2022.09.010 · Cited by 10
Ye, X., Feng, Z., Wang, Z., Zheng, L., Yuan, Y., Hu, Y., & Xu, Y. (2022) · Brain Sciences · doi:10.3390/brainsci12101350 · Cited by 8
“A-HFS sequences were applied with a duration of 2 min and a pulse frequency of 100 Hz in the DBS frequency range of 50–200 Hz [2,3,20].”
MethodKhzam, R. A., Jalbout, N. D. E., Seif, R., & Sadaka, A. (2022) · American Journal of Ophthalmology Case Reports · doi:10.1016/j.ajoc.2022.101531 · Cited by 7
Raju, V. R. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9023-3_12 · Cited by 7
Shuto, Y., Walinda, E., Morimoto, D., & Sugase, K. (2023) · The Journal of Physical Chemistry B · doi:10.1021/acs.jpcb.3c01683 · Cited by 6
Dong, W., Qiu, C., Chang, L., Sun, J., Yan, J., Luo, B., Lu, Y., Liu, W., Zhang, L., & Zhang, W. (2023) · CNS Neuroscience & Therapeutics · doi:10.1111/cns.14501 · Cited by 6
Ågren, R., Bartek, J. J., Johansson, A., Blomstedt, P. C., & Fytagoridis, A. (2020) · Stereotactic and Functional Neurosurgery · doi:10.1159/000508794 · Cited by 7
Zou, X., Shi, Y., Wu, X., Ye, Q., Lin, F., & Cai, G. (2022) · Neurological Sciences · doi:10.1007/s10072-022-06484-z · Cited by 6
“By reviewing the full text, 1 article was excluded because it was a trial proposal [23], 3 articles were excluded due to unavailable original data [24–26], 2 articles were excluded due to non-use of DBS with pulse widths less than 60 μs as an intervention [27, 28], and 1 article was excluded due to inclusion of patien…”
BackgroundSu, D., Wu, K., Saha, R., & Wang, J.-P. (2019) · Journal of Applied Physics · doi:10.1063/1.5122753 · Cited by 6
Liu, C., Yao, Y., Wang, J., Li, H., Wu, H., Loparo, K. A., & Fietkiewicz, C. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103466 · Cited by 6
de Oliveira, A. M. R., de Carvalho, E. A., Barros, B., Soares, C., Ferreira‐Pinto, M. J., Vaz, R. M., & Aguiar, P. (2024) · npj Parkinson s Disease · doi:10.1038/s41531-024-00740-z · Cited by 5
“…the best performing stimulation parameters (i.e., a combination of higher symptom mitigation and lower incidence of adverse effects) from established therapeutic parameter ranges 7 – 9 ; after selection, the parameters are kept until the following clinical session, where they are re-adjusted.”
BackgroundZhou, H., Wang, X., Gu, H., & Jia, Y. (2025) · Cognitive Neurodynamics · doi:10.1007/s11571-025-10267-5 · Cited by 5
“The different parts of BG are coupled via inhibitory or excitatory synapses (Dayal et al. 2017; Shen et al. 2020; Adam et al. 2022; Chu et al. 2022).”
Acoustoelectric Time-Reversal for Ultrasound Phase-Aberration Correction
Preston, C., Alvarez, A. M., Allard, M., Barragan, A., & Witte, R. S. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3292595 · Cited by 7
“still detect the AE signal required for AETR [69], [70], [71],”
Wu, Z., Ren, Z., Gao, R., Sun, K., Sun, F., Liu, T., Zheng, S., Wang, W., & Zhang, G. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e30730 · Cited by 5
“Frequency is particularly crucial, influencing intervention effectiveness, with evidence linking it to clinical responses [53].”
BackgroundPfister, R., & Demmel, W. (2021) · Nervenheilkunde · doi:10.1055/a-1586-5574 · Cited by 4
Electrophysiological Characterization of Substantia Nigra Pars Reticulata in Anesthetized Rats
Liu, X., Zhang, Q., Wang, Y., & Chen, F. (2022) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-022-2420-y · Cited by 4
“In clinical practice, subthalamic nucleus (STN)([21]), pedunculopontine nucleus (PPN)([22]) and globus pallidus interna (GPi)([23]) are common DBS targets.”
BackgroundPutting deep brain stimulation for depression in a wider perspective
Bergfeld, I. O. (2019) · The Lancet Psychiatry · doi:10.1016/s2215-0366(19)30476-6 · Cited by 4
Younce, J. R., Norris, S. A., Ushe, M., & Perlmutter, J. S. (2025) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.70108 · Cited by 3
“49 For each predictor set, we fi rst constructed a sparse model using relaxed LASSO.”
D’Ascanio, I., Giannini, G., Baldelli, L., Cani, I., Giannoni, A., Leogrande, G., Lopane, G., Buonaura, G. C., Cortelli, P., Chiari, L., et al. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad5e83 · Cited by 3
Predictive modeling of sensory responses in deep brain stimulation
Halász, L., Sajonz, B., Miklós, G., van Elswijk, G., Gooie, S. H., Várkuti, B., Tamás, G., Coenen, V. A., & Erőss, L. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1467307 · Cited by 3
Milanowski, J., Pawłowska, M., Woźniak, A., & Szewczyk‐Golec, K. (2025) · Molecules · doi:10.3390/molecules30224431 · Cited by 3
“It involves the implantation of electrodes connected to a stimulator in brain regions such as the subthalamic nucleus (STN) or the globus pallidus internus (GPi) [24,25].”
Procedure‐Related Complications in Sham Surgeries for Parkinson's Clinical Trials: A Meta‐analysis
Mamaril‐Davis, J., Gelb, A. W., & Larson, P. (2023) · Movement Disorders · doi:10.1002/mds.29406 · Cited by 4
Ranjan, R., Chourey, A., Kabir, Y., Mata, H. D. G., Tiepolo, E., Vinueza, I. L. F., Mohammed, C., Mohammed, S. F., & Thottakurichi, A. A. (2024) · Cureus · doi:10.7759/cureus.72613 · Cited by 3
“The main parameters that can be programmed in DBS are the designation of a cathode, an anode, amplitude, pulse width, and rate [42].”
InfluentialHidding, U., Lezius, S., Schaper, M., Buhmann, C., Gerloff, C. P., Pötter‐Nerger, M., Hamel, W., Moll, C. K. E., & Choe, C. (2022) · Neuromodulation Technology at the Neural Interface · doi:10.1016/j.neurom.2022.09.009 · Cited by 3
Vij, R., Kim, H., Park, H., Lotfi, D., Cheng, T., & Chang, D. (2026) · Parkinson s Disease · doi:10.1155/padi/9934417 · Cited by 2
Optimizing Deep Brain Stimulation Programming in Parkinson’s Disease
Gupta, F., & Agrawal, P. (2018) · Springer eBooks · doi:10.1007/978-3-319-23693-3_7 · Cited by 2
Far, R., Sáez, I., Sardo, A., Ovruchesky, E., Sperry, L., Zhang, L., Shahlaie, K., & Girgis, F. (2022) · Acta Neurochirurgica · doi:10.1007/s00701-022-05279-7 · Cited by 2
“Previous studies in both humans and animals have shown a clear relationship between increasing stimulation intensity (i.e., amplitude) and PD motor symptom relief [4, 21].”
InfluentialCastillo-Triana, N., Camargo-Mendoza, M., & Bernal-Pacheco, Ó. (2024) · CoDAS · doi:10.1590/2317-1782/20242023194en · Cited by 1
“DBS aims to ameliorate or counteract pathological neural activity by delivering a localized continuous electrical current into specific target brain regions (21,22) such as internal globus pallidus (23) , zona incerta (24) , or the subthalamic nucleus (23,25) .”
BackgroundÇelik, N. D., Kula, A. Y., Tekkanat, E. G. Y., Kumcu, M. K., Yanardağ, M., & Özkan, S. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13216357 · Cited by 1
Zhao, H., Huang, F., Zhu, R., Zhang, B., Wang, X., Xu, X., & Qin, H. (2026) · Applied Physics Letters · doi:10.1063/5.0316951 · Cited by 1
Yoon, S. H. (2026) · Journal of Brain Neuromodulation Therapy · doi:10.66227/jbnt.2026.1.1.14 · Cited by 1
Tchantchaleishvili, N., Netliukh, A., & Ganau, M. (2026) · Clinical Parkinsonism & Related Disorders · doi:10.1016/j.prdoa.2026.100444 · Cited by 1
“Levodopa-resistant freezing of gait emerging immediately after electrode implantation was reported in isolated cases and small series, independent of stimulation activation [33].”
Zheng, X., Yu, L., Wan, X., Wang, H., Yu, T., He, Q., Lin, Z., & Kang, D. (2019) · Europe PMC (PubMed Central) · doi:10.12122/j.issn.1673-4254.2019.12.10 · Cited by 1
Current Research on Deep Brain Stimulation and Cognitive Impairment in Parkinson’s Disease
Shahlaie, K., Sperry, L., Wei, L., & Zhang, L. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.101603 · Cited by 1
“Adjustments in the stimulation field, amplitude, frequency, and pulse-width control the stimulation response [29].”
BackgroundTerra, H. D. C. B., Borges, F. S., Moraes, M. F. D., & Cota, V. R. (2022) · Communications in computer and information science · doi:10.1007/978-3-031-08443-0_8 · Cited by 1
Brain Oedema Associated with Deep Brain Stimulation through a Single Directional Contact
Girges, C., Krüger, M. T., Xu, S. S., Akram, H., Hyam, J. A., Limousin, P. D., Zrinzo, L. U., & Foltynie, T. (2023) · Movement Disorders Clinical Practice · doi:10.1002/mdc3.13871 · Cited by 1
“9 Further investigation is needed to fully understand whether these clinical and imaging abnormalities were a side effect of high current density during unidirectional stimulation.”
BackgroundSelf-citation
Metadata
- Authors
- Dayal, V., Limousin, P., & Foltynie, T.
- Affiliations
- National Hospital for Neurology and Neurosurgery (GB)
- Corresponding author
- Dayal, Viswas
- Venue
- Journal of Parkinson’s Disease
- Publisher
- SAGE Publications
- Published
- 2017-03-20
- Volume
- 7
- Issue
- 2
- Pages
- 235-245
- ISSN
- 1877-7171 (ISSN-L)
- 1877-718X
- PMC
- PMC5438474
- OpenAlex
- W2613412037
- Cited by
- 108
- References
- 52
- Citations by year
- 2026: 7 · 2025: 7 · 2024: 12 · 2023: 16 · 2022: 18 · 2021: 15 · 2020: 16 · 2019: 9 · 2018: 6 · 2017: 2
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Journal of Parkinson s Disease (publishedVersion, cc-by-nc)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- UCL Discovery (University College London) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Social Sciences › Psychology › Clinical Psychology › Obsessive-Compulsive Spectrum Disorders
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- subthalamic nucleus, deep brain stimulation, Parkinson's disease, stimulation parameters, stimulation intensity, stimulation frequency, pulse duration, DBS programming, therapeutic window, freezing of gait, axial symptoms, adaptive stimulation
- MeSH terms
- Humans, Parkinson Disease, Treatment Outcome, Subthalamic Nucleus, Deep Brain Stimulation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.