Continuous multifunction myoelectric control using pattern recognition
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This work represents an ongoing investigation of dexterous and natural control of upper extremity prostheses using the myoelectric signal. The scheme described within uses pattern recognition to process four channels of myoelectric signal, with the t
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 2×
“A neural network based classifier was constructed, and was shown to permit an accuracy of roughly 90% in a four-class problem [19].”
Self-citationA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
Self-citation
Cited by
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Huang, Y., Englehart, K. B., Hudgins, B., & Chan, A. D. C. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856295 · Cited by 643
Self-citationMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
The optimal controller delay for myoelectric prostheses
Farrell, T. R., & Weir, R. F. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.891391 · Cited by 438
Continuous Myoelectric Control for Powered Prostheses Using Hidden Markov Models
Chan, A. D. C., & Englehart, K. B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.836492 · Cited by 343
Self-citationCurrent state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Online Electromyographic Control of a Robotic Prosthesis
Shenoy, P., Miller, K. J., Crawford, B., & Rao, R. P. N. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909536 · Cited by 285
Samuel, O. W., Asogbon, M. G., Geng, Y., Al-Timemy, A. H., Pirbhulal, S., Ji, N., Chen, S., Fang, P., & Li, G. (2019) · IEEE Access · doi:10.1109/access.2019.2891350 · Cited by 185
“Meanwhile, other previously proposed feature extraction methods includes: Fast Fourier transform (STFT) based features [34], [35], wavelets based features and wavelet packet transform (WPT) based features [34], cepstral coefficients (CC), Willison amplitude (WAMP) [36], sample entropy (SampEnt) [37], reduced spectral…”
Method
Metadata
- Authors
- Englehart, K., Hudgins, B., & Chan, A. D. C.
- Venue
- Technology and Disability
- Publisher
- SAGE Publications
- Published
- 2003-08-27
- Volume
- 15
- Issue
- 2
- Pages
- 95-103
- ISSN
- 1055-4181 (ISSN-L)
- 1878-643X
- OpenAlex
- W1929650848
- Cited by
- 95
- References
- 2
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.