A guiding approach of Ultrasound scan for accurately obtaining standard diagnostic planes of fetal brain malformation
Abstract
BACKGROUND: Standard planes (SPs) are crucial for the diagnosis of fetal brain malformation. However, it is very time-consuming and requires extensive experiences to acquire the SPs accurately due to the large difference in fetal posture and the complexity of SPs definitions. OBJECTIVE: This study aims to present a guiding approach that could assist sonographer to obtain the SPs more accurately and more quickly. METHODS: To begin with, sonographer uses the 3D probe to scan the fetal head to obtain 3D volume data, and then we used affine transformation to calibrate 3D volume data to the standard body position and established the corresponding 3D head model in ‘real time’. When the sonographer uses the 2D probe to scan a plane, the position of current plane can be clearly show in 3D head model by our RLNet (regression location network), which can conduct the sonographer to obtain the three SPs more accurately. When the three SPs are located, the sagittal plane and the coronal planes can be automatically generated according to the spatial relationship with the three SPs. RESULTS: Experimental results conducted on 3200 2D US images show that the RLNet achieves average angle error of the transthalamic plane was 3.91±2.86°, which has a obvious improvement compared other published data. The automatically generated coronal and sagittal SPs conform the diagnostic criteria and the diagnostic requirements of fetal brain malformation. CONCLUSIONS: A guiding scanning method based deep learning for ultrasonic brain malformation screening is firstly proposed and it has a pragmatic value for future clinical application.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Yeung et al., Namburete et al., Yu et al., and Di Vece et al. proposed a plane localization system as a 3D reference space for locating 2D planes to improve acquisition of standard planes and facilitate anatomical orientation.
“The establishment of a plane localization system as a 3D reference space for locating 2D planes was proposed by Yeung et al., Namburete et al., Yu et al., and Di Vece et al. for improving the acquisition of standard planes and facilitating anatomical orientation for sonographers [78,80,82,83].”
AI algorithms in fetal neurosonography enabled the development of guiding methods for skill training.
“the development of guiding methods for skill training [78,83]”
Cites
Image quality assessment: from error visibility to structural similarity
Wang, Z., Bovik, A. C., Sheikh, H. R., & Simoncelli, E. P. (2004) · IEEE Transactions on Image Processing · doi:10.1109/tip.2003.819861 · Cited by 57,892 · see citing works
Salomon, L. J., Alfirevic, Z., Berghella, V., Bilardo, C. M., Chalouhi, G. E., Da Silva Costa, F., Hernandez‐Andrade, E., Malinger, G., Munoz, H., Paladini, D., et al. (2022) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.24888 · Cited by 436 · see citing works
Yaqub, M., Kelly, B., Papageorghiou, A. T., & Noble, J. A. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.07.013 · Cited by 67 · see citing works
Standard Plane Localization in Ultrasound by Radial Component Model and Selective Search
Ni, D., Yang, X., Chen, X., Chin, C.-T., Chen, S., Heng, P. A., Li, S., Qin, J., & Wang, T. (2014) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2014.06.006 · Cited by 65 · see citing works
Agent with Warm Start and Adaptive Dynamic Termination for Plane Localization in 3D Ultrasound
Yang, X., Dou, H., Huang, R., Xue, W., Huang, Y., Qian, J., Zhang, Y., Luo, H., Guo, H., Wang, T., et al. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3069663 · Cited by 32 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Jost, E., Kosian, P., Jimenez Cruz, J., Albarqouni, S., Gembruch, U., Strizek, B., & Recker, F. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216833 · Cited by 44 · see citing works
“The establishment of a plane localization system as a 3D reference space for locating 2D planes was proposed by Yeung et [78,80,82,83].”
BackgroundMethod
- Authors
- Yu, Y., Chen, Z., Zhuang, Y., Yi, H., Han, L., Chen, K., & Lin, J.
- Affiliations
- Sichuan University (CN)
- Chengdu Military General Hospital (CN)
- Corresponding author
- Lin, Jiangli
- Venue
- Journal of X-Ray Science and Technology
- Publisher
- SAGE Publications
- Published
- 2022-11-24
- Volume
- 30
- Issue
- 6
- Pages
- 1243-1260
- ISSN
- 0895-3996 (ISSN-L)
- 1095-9114
- OpenAlex
- W4297019197
- Cited by
- 2
- References
- 5
- Citations by year
- 2025: 1 · 2023: 1
- FWCI
- 0.55
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of X-Ray Science and Technology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Fetal and Pediatric Neurological Disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
- Health Sciences › Medicine › Health Informatics › Artificial Intelligence in Healthcare and Education
- Keywords
- fetal brain malformations, ultrasound guidance, 3D ultrasound, affine transformation, 3D head model, sagittal plane, frontal plane, deep learning
- MeSH terms
- Brain, Female, Head, Humans, Pregnancy, Ultrasonography, Ultrasonography, Prenatal
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›