The clinical effectiveness and cost-effectiveness of inhaled insulin in diabetes mellitus: a systematic review and economic evaluation
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To review the clinical effectiveness and cost-effectiveness of a new technology, the inhaled insulin, Exubera (Pfizer and Sanofi-Aventis, in collaboration with Nektar Therapeutics), a short-acting insulin. DATA SOURCES: Electronic databases were searched up to November 2005. REVIEW METHODS: A systematic literature review was conducted and economic modelling carried out. An industry model was used for modelling. RESULTS: Nine trials of inhaled insulins were found, but only seven used the Exubera form of inhaled insulin. The other two used inhaled insulins that have not yet been licensed. There were five trials in type 1 and two in type 2 diabetes. Inhaled insulin is clinically effective, and is as good as short-acting soluble insulin in controlling blood glucose, plus it works slightly more quickly. None of the published trials compared it with short-acting analogues. Most patients in the trials were on combinations of short-acting, and either long- or intermediate-acting insulin, and both were changed, making it more difficult to assess the effects of only the change from soluble to inhaled insulin. Patient preference was the only significant difference between inhaled and soluble insulin in the trials. Most patients preferred inhaled to injected short-acting insulin, and this has some effect on quality of life measures. However, the control groups mostly used syringes and needles, rather than pens. As pens are more convenient, their use might have narrowed the patient satisfaction difference. There were no trials of inhaled insulin against continuous subcutaneous insulin infusion (CSII). No serious adverse experiences of inhaled insulin in the lung have been seen to date, but it is too soon yet to judge long-term effects. The manufacturer's model appears to be a high-quality one, although the results depend more on the assumptions fed into the model than on the model itself. The key assumptions are the size of the gain in quality of life utility from inhaling rather than injecting insulin, the effect of having an inhaled option on the willingness to start insulin among people with poor diabetic control on oral drugs, and the effect on glycaemic control. We consider that these assumptions make the cost-effectiveness appear better than it really would be. The manufacturer's submission assumed utility gains of 0.036-0.075 in patients with type 1 diabetes, and 0.027-0.067 in those with type 2, based on an unpublished utility elicitation study sponsored by the manufacturer. We thought that these gains were optimistic and that gains of 0.02 or less were more likely, on average. However, patients with particular problems with injection sites might have more to gain, although they might also be a group with much to gain from CSII. A key factor is the cost of inhaled insulin. Much more insulin has to be given by inhaler than by injection, and so the cost of inhaled insulin is much higher than injected. The extra cost depends on dosage but ranges from around 600 pounds to over 1000 pounds per patient per year. CONCLUSIONS: The inhaled insulin, Exubera, appears to be as effective, but no better than injected short-acting insulin. The additional cost is so much more that it is unlikely to be cost-effective. The long-term safety is uncertain. Additional research is recommended into the safety, efficacy and cost-effectiveness of inhaled insulin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
(1997) · doi:10.1097/00005650-199711000-00002 · Cited by 4,544
Ohkubo, Y., Kishikawa, H., Araki, E., Miyata, T., Isami, S., Motoyoshi, S., Kojima, Y., Furuyoshi, N., & Shichiri, M. (1995) · Diabetes Research and Clinical Practice · doi:10.1016/0168-8227(95)01064-k · Cited by 3,079
Evaluating patient-based outcome measures for use in clinical trials.
Fitzpatrick, Davey, Buxton, & Jones (1998) · Health Technology Assessment · doi:10.3310/hta2140 · Cited by 1,715
Pathologic anatomy of the pancreas in juvenile diabetes mellitus
Gepts, W. (1965) · Diabetes · doi:10.2337/diab.14.10.619 · Cited by 1,345
Pharmacologic Therapy for Type 2 Diabetes Mellitus
DeFronzo, R. A. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-4-199908170-00008 · Cited by 1,173
Early Metabolic Defects in Persons at Increased Risk for Non-Insulin-Dependent Diabetes Mellitus
Eriksson, J., Franssila-Kallunki, A., Ekstrand, A., Saloranta, C., Widén, E., Schalin, C., & Groop, L. (1989) · New England Journal of Medicine · doi:10.1056/nejm198908103210601 · Cited by 807
Initiating Insulin Therapy in Type 2 Diabetes
Raskin, P., Allen, E., Hollander, P., Lewin, A., Gabbay, R. A., Hu, P., Bode, B., Garber, A., & for the INITIATE Study Group (2005) · Diabetes Care · doi:10.2337/diacare.28.2.260 · Cited by 560
Psychological Insulin Resistance in Patients With Type 2 Diabetes
Polonsky, W. H., Fisher, L., Guzman, S., Villa-Caballero, L., & Edelman, S. V. (2005) · Diabetes Care · doi:10.2337/diacare.28.10.2543 · Cited by 551
Janka, H. U., Plewe, G., Riddle, M. C., Kliebe-Frisch, C., Schweitzer, M. A., & Yki-Järvinen, H. (2005) · Diabetes Care · doi:10.2337/diacare.28.2.254 · Cited by 414
Injection related anxiety in insulin-treated diabetes
Zambanini, A., Newson, R. B., Maisey, M., & Feher, M. D. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00099-6 · Cited by 289
Variability of Insulin Absorption and Insulin Action
Heinemann, L. (2002) · Diabetes Technology & Therapeutics · doi:10.1089/152091502320798312 · Cited by 267
Gerstein, H. C., Yale, J. ‐., Harris, S. B., Issa, M., Stewart, J. A., & Dempsey, E. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01881.x · Cited by 197
Pharmacologic Therapy for Type 2 Diabetes Mellitus
DeFronzo, R. A. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-1-200007040-00016 · Cited by 176
McQuay, & Moore (1998) · Health Technology Assessment · doi:10.3310/hta2120 · Cited by 131
Deteriorating beta–cell function in type 2 diabetes: a long–term model
Bagust, A., & Beale, S. (2003) · QJM: An International Journal of Medicine · doi:10.1093/qjmed/hcg040 · Cited by 105
Cited by
Type 2 Diabetes Mellitus: A Review of Current Trends
Olokoba, A. B., Obateru, O. A., & Olokoba, L. B. (2012) · Oman Medical Journal · doi:10.5001/omj.2012.68 · Cited by 1,338
The Current State of Peptide Drug Discovery: Back to the Future?
Henninot, A., Collins, J. C., & Nuss, J. M. (2018) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.7b00318 · Cited by 1,113
Halliday, A., & Bax, J. J. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.03.004 · Cited by 651
An overview of clinical and commercial impact of drug delivery systems
Anselmo, A. C., & Mitragotri, S. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.053 · Cited by 520
Turning the Pyramid of Prenatal Care
Nicolaides, K. H. (2011) · Fetal Diagnosis and Therapy · doi:10.1159/000324320 · Cited by 357
Metadata
- Authors
- Black, C., Cummins, E., Royle, P., Philip, S., & Waugh, N.
- Venue
- Health Technology Assessment
- Published
- 2007-09
- Volume
- 11
- Issue
- 33
- Pages
- 1-126
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2100785305
- Cited by
- 147
- References
- 18
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.