Integrated sensor-augmented pump therapy systems [the MiniMed® Paradigm™ Veo system and the Vibe™ and G4® PLATINUM CGM (continuous glucose monitoring) system] for managing blood glucose levels in type 1 diabetes: a systematic review and economic evaluation
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Background: In recent years, meters for continuous monitoring of interstitial fluid glucose have been introduced to help people with type 1 diabetes mellitus (T1DM) to achieve better control of their disease. Objective: The objective of this project was to summarise the evidence on the clinical effectiveness and cost-effectiveness of the MiniMed®Paradigm™ Veo system (Medtronic Inc., Northridge, CA, USA) and the Vibe™ (Animas®Corporation, West Chester, PA, USA) and G4®PLATINUM CGM (continuous glucose monitoring) system (Dexcom Inc., San Diego, CA, USA) in comparison with multiple daily insulin injections (MDIs) or continuous subcutaneous insulin infusion (CSII), both with either self-monitoring of blood glucose (SMBG) or CGM, for the management of T1DM in adults and children. Data sources: A systematic review was conducted in accordance with the principles of the Centre for Reviews and Dissemination guidance and the National Institute for Health and Care Excellence Diagnostic Assessment Programme manual. We searched 14 databases, three trial registries and two conference proceedings from study inception up to September 2014. In addition, reference lists of relevant systematic reviews were checked. In the absence of randomised controlled trials directly comparing Veo or an integrated CSII + CGM system, such as Vibe, with comparator interventions, indirect treatment comparisons were performed if possible. Methods: A commercially available cost-effectiveness model, the IMS Centre for Outcomes Research and Effectiveness diabetes model version 8.5 (IMS Health, Danbury, CT, USA), was used for this assessment. This model is an internet-based, interactive simulation model that predicts the long-term health outcomes and costs associated with the management of T1DM and type 2 diabetes. The model consists of 15 submodels designed to simulate diabetes-related complications, non-specific mortality and costs over time. As the model simulates individual patients over time, it updates risk factors and complications to account for disease progression. Results: Fifty-four publications resulting from 19 studies were included in the review. Overall, the evidence suggests that the Veo system reduces hypoglycaemic events more than other treatments, without any differences in other outcomes, including glycated haemoglobin (HbA 1c) levels. We also found significant results in favour of the integrated CSII + CGM system over MDIs with SMBG with regard to HbA 1c levels and quality of life. However, the evidence base was poor. The quality of the included studies was generally low, often with only one study comparing treatments in a specific population at a specific follow-up time. In particular, there was only one study comparing Veo with an integrated CSII + CGM system and only one study comparing Veo with a CSII + SMBG system in a mixed population. Cost-effectiveness analyses indicated that MDI + SMBG is the option most likely to be cost-effective, given the current threshold of £30,000 per quality-adjusted life-year gained, whereas integrated CSII + CGM systems and Veo are dominated and extendedly dominated, respectively, by stand-alone, non-integrated CSII with CGM. Scenario analyses did not alter these conclusions. No cost-effectiveness modelling was conducted for children or pregnant women. Conclusions: The Veo system does appear to be better than the other systems considered at reducing hypoglycaemic events. However, in adults, it is unlikely to be cost-effective. Integrated systems are also generally unlikely to be cost-effective given that stand-alone systems are cheaper and, possibly, no less effective. However, evidence in this regard is generally lacking, in particular for children. Future trials in specific child, adolescent and adult populations should include longer term follow-up and ratings on the European Quality of Life-5 Dimensions scale at various time points with a view to informing improved cost-effectiveness modelling. Study registration: PROSPERO Registration Number CRD42014013764. Funding: The National Institute for Health Research Health Technology Assessment programme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shepherd, J., Blauw, G. J., Murphy, M. B., Bollen, E. L., Buckley, B. M., Cobbe, S. M., Ford, I., Gaw, A., Hyland, M., Jukema, J. W., et al. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11600-x · Cited by 3,378
High-Dose Atorvastatin after Stroke or Transient Ischemic Attack
The Stroke Prevention by Aggressive Reduction in Cholesterol Levels (SPARCL) Investigators (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061894 · Cited by 2,887
Probability of stroke: a risk profile from the Framingham Study.
Wolf, P. A., D'Agostino, R. B., Belanger, A. J., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.3.312 · Cited by 1,782
Malmberg, K., Rydén, L., Efendic, S., Herlitz, J., Nicol, P., Waldenstrom, A., Wedel, H., & Welin, L. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00126-k · Cited by 1,560
The UKPDS risk engine: a model for the risk of coronary heart disease in Type II diabetes (UKPDS 56)
STEVENS, R. J., KOTHARI, V., ADLER, A. I., & STRATTON, I. M. (2001) · Clinical Science · doi:10.1042/cs20000335 · Cited by 1,084
Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes
Bergenstal, R. M., Tamborlane, W. V., Ahmann, A., Buse, J. B., Dailey, G., Davis, S. N., Joyce, C., Peoples, T., Perkins, B. A., Welsh, J. B., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1002853 · Cited by 894
Cited by
Bekiari, E., Kitsios, K., Thabit, H., Tauschmann, M., Athanasiadou, E., Karagiannis, T., Haidich, A.-B., Hovorka, R., & Tsapas, A. (2018) · BMJ · doi:10.1136/bmj.k1310 · Cited by 437
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Abbas, A., Hefnawy, M. T., & Negida, A. (2024) · BMC Medical Research Methodology · doi:10.1186/s12874-024-02356-6 · Cited by 263
Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
Mian, Z., Hermayer, K. L., & Jenkins, A. (2019) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2019.07.003 · Cited by 139
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Intermittent fasting for the prevention of cardiovascular disease
Allaf, M., Elghazaly, H., Mohamed, O. G., Fareen, M. F. K., Zaman, S., Salmasi, A.-M., Tsilidis, K., & Dehghan, A. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013496.pub2 · Cited by 98
Heller, S., White, D., Lee, E., Lawton, J., Pollard, D., Waugh, N., Amiel, S., Barnard, K., Beckwith, A., Brennan, A., et al. (2017) · Health Technology Assessment · doi:10.3310/hta21200 · Cited by 73
Garg, S. K., Grunberger, G., Weinstock, R., Lawson, M. L., Hirsch, I. B., DiMeglio, L. A., Pop-Busui, R., Philis-Tsimikas, A., Kipnes, M., Liljenquist, D. R., et al. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0421 · Cited by 63
“The Medtronic MiniMed 530G and MiniMed Veo systems (Medtronic, Northridge, CA) 8,9 provided this with ‘‘threshold suspend’’ and ‘‘low-glucose suspend,’’ and were available as early as 2013.”
Bratke, H., Margeirsdottir, H. D., Assmus, J., Njølstad, P. R., & Skrivarhaug, T. (2021) · Diabetes Therapy · doi:10.1007/s13300-021-01127-6 · Cited by 20
Metadata
- Authors
- Riemsma, R., Corro Ramos, I., Birnie, R., Büyükkaramikli, N., Armstrong, N., Ryder, S., Duffy, S., Worthy, G., Al, M., Severens, J., & Kleijnen, J.
- Venue
- Health Technology Assessment
- Published
- 2016-02
- Volume
- 20
- Issue
- 17
- Pages
- 1-252
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2297363521
- Cited by
- 73
- References
- 30
- FWCI
- 1.95
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.