The DOI matches its Crossref record; 125 of the 125 references it cites were found in a registry or an index.
Development and validation of methods for assessing the quality of diagnostic accuracy studies
Open accessAbstract
OBJECTIVES: To develop a quality assessment tool which will be used in systematic reviews to assess the quality of primary studies of diagnostic accuracy. DATA SOURCES: Electronic databases including MEDLINE, EMBASE, BIOSIS and the methodological databases of both CRD and the Cochrane Collaboration. REVIEW METHODS: Three systematic reviews were conducted to provide an evidence base for the development of the quality assessment tool. A Delphi procedure was used to develop the quality assessment tool and the information provided by the reviews was incorporated into this. A panel of nine experts in the area of diagnostic accuracy studies took part in the Delphi procedure to agree on the items to be included in the tool. Panel members were also asked to provide feedback on various other items and whether they would like to see the development of additional topic and design specific items. The Delphi procedure produced the quality assessment tool, named the QUADAS tool, which consisted of 14 items. A background document was produced describing each item included in the tool and how each of the items should be scored. RESULTS: The reviews produced 28 possible items for inclusion in the quality assessment tool. It was found that the sources of bias supported by the most empirical evidence were variation by clinical and demographic subgroups, disease prevalence/severity, partial verification bias, clinical review bias and observer/instrument variation. There was also some evidence of bias for the effects of distorted selection of participants, absent or inappropriate reference standard, differential verification bias and review bias. The evidence for the effects of other sources of bias was insufficient to draw conclusions. The third review found that only one item, the avoidance of review bias, was included in more than 75% of tools. Spectrum composition, population recruitment, absent or inappropriate reference standard and verification bias were each included in 50-75% of tools. Other items were included in less than 50% of tools. The second review found that the quality assessment tool should have the potential to be discussed narratively, reported in a tabular summary, used as recommendations for future research, used to conduct sensitivity or regression analyses and used as criteria for inclusion in the review or a primary analysis. This suggested that some distinction is needed between high- and low-quality studies. Component analysis was considered the best approach to incorporate quality into systematic reviews of diagnostic studies and this was taken into consideration when developing the tool. CONCLUSIONS: This project produced an evidence-based quality assessment tool to be used in systematic reviews of diagnostic accuracy studies. Through the various stages of the project the current lack of such a tool and the need for a systematically developed validated tool were demonstrated. Further work to validate the tool continues beyond the scope of this project. The further development of the tool by the addition of design- and topic-specific criteria is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
Two-sided confidence intervals for the single proportion: comparison of seven methods
Newcombe, R. G. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980430)17:8<857::aid-sim777>3.0.co;2-e · Cited by 5,107
Moher, D., Pham, B., Jones, A., Cook, D. J., Jadad, A. R., Moher, M., Tugwell, P., & Klassen, T. P. (1998) · The Lancet · doi:10.1016/s0140-6736(98)01085-x · Cited by 3,560
Empirical evidence of design-related bias in studies of diagnostic tests.
Lijmer, J. G. (1999) · JAMA · doi:10.1001/jama.282.11.1061 · Cited by 1,861
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Systematic reviews of evaluations of diagnostic and screening tests
Deeks, J. J. (2001) · BMJ · doi:10.1136/bmj.323.7305.157 · Cited by 1,340
The STARD Statement for Reporting Studies of Diagnostic Accuracy: Explanation and Elaboration
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Moher, D., Rennie, D., de Vet, H. C. W., & Lijmer, J. G. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00012-w1 · Cited by 1,124
Self-citationJaeschke, R. (1994) · JAMA · doi:10.1001/jama.1994.03510290071040 · Cited by 1,049
Metz, C. E., Herman, B. A., & Shen, J.-H. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9<1033::aid-sim784>3.0.co;2-z · Cited by 793
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Use of methodological standards in diagnostic test research. Getting better but still not good
Reid, M. C. (1995) · JAMA · doi:10.1001/jama.274.8.645 · Cited by 712
Assessment of diagnostic tests when disease verification is subject to selection bias
Begg, C. B., & Greenes, R. A. (1983) · Biometrics · doi:10.2307/2530820 · Cited by 708
Noninvasive Diagnosis of Deep Venous Thrombosis
Kearon, C., Julian, J. A., Math, M., Newman, T. E., & Ginsberg, J. S. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-8-199804150-00011 · Cited by 690
Meta-analysis of Pap Test Accuracy
Fahey, M. T., Irwig, L., & Macaskill, P. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117485 · Cited by 684
McGee, S. (1999) · JAMA · doi:10.1001/jama.281.11.1022 · Cited by 583
Biases in the assessment of diagnostic tests
Begg, C. B. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060402 · Cited by 496
Epidemiologic issues in the validation of veterinary diagnostic tests
Greiner, M., & Gardner, I. A. (2000) · Preventive Veterinary Medicine · doi:10.1016/s0167-5877(00)00114-8 · Cited by 484
Meta-analytic methods for diagnostic test accuracy
Irwig, L., Macaskill, P., Glasziou, P., & Fahey, M. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00099-c · Cited by 467
Metlay, J. P. (1997) · JAMA · doi:10.1001/jama.278.17.1440 · Cited by 438
Factors affecting sensitivity and specificity of exercise electrocardiography
Hlatky, M. A., Pryor, D. B., Harrell, F. E., Califf, R. M., Mark, D. B., & Rosati, R. A. (1984) · The American Journal of Medicine · doi:10.1016/0002-9343(84)90437-6 · Cited by 371
Moher, Cook, Jadad, Tugwell, Moher, Jones, Pham, & Klassen (1999) · Health Technology Assessment · doi:10.3310/hta3120 · Cited by 368
Walter, S. (1988) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(88)90110-2 · Cited by 360
The performance of CA-125 measurement in the detection of endometriosis: a meta-analysis
Mol, B. W. J., Bayram, N., Lijmer, J. G., Wiegerinck, M. A. H. M., Bongers, M. Y., van der Veen, F., & Bossuyt, P. M. M. (1998) · Fertility and Sterility · doi:10.1016/s0015-0282(98)00355-0 · Cited by 355
Self-citationEXPLAINED VARIATION FOR LOGISTIC REGRESSION
Mittlböck, M., & SCHEMPER, M. (1996) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19961015)15:19<2121::aid-sim346>3.0.co;2-m · Cited by 335
Rao, J. K., Weinberger, M., Oddone, E. Z., Allen, N. B., Landsman, P., & Feussner, J. R. (1995) · Annals of Internal Medicine · doi:10.7326/0003-4819-123-12-199512150-00005 · Cited by 322
Routine preoperative testing: a systematic review of the evidence.
Munro, Booth, & Nicholl (1997) · Health Technology Assessment · doi:10.3310/hta1120 · Cited by 322
The Declining Specificity of Exercise Radionuclide Ventriculography
Rozanski, A., Diamond, G. A., Berman, D., Forrester, J. S., Morris, D., & Swan, H. J. C. (1983) · New England Journal of Medicine · doi:10.1056/nejm198309013090902 · Cited by 316
Selecting and Appraising Studies for a Systematic Review
Meade, M. O., & Richardson, W. S. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-7-199710010-00005 · Cited by 283
Diagnosis, management and screening of early localised prostate cancer.
Selley, Donovan, Faulkner, Coast, & Gillatt (1997) · Health Technology Assessment · doi:10.3310/hta1020 · Cited by 277
Neonatal screening for inborn errors of metabolism: cost, yield and outcome.
Pollitt, Green, McCabe, Booth, Cooper, Leonard, Nicholl, Nicholson, Tunaley, & Virdi (1997) · Health Technology Assessment · doi:10.3310/hta1070 · Cited by 267
Lachs, M. S., Nachamkin, I., Edelstein, P. H., Goldman, J., Feinstein, A. R., & Schwartz, J. S. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-2-135 · Cited by 261
Can the Clinical Examination Diagnose Left-Sided Heart Failure in Adults?
Badgett, R. G. (1997) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1997.03540450068038 · Cited by 248
Irwig, L. (2002) · BMJ · doi:10.1136/bmj.324.7338.669 · Cited by 246
Monitoring blood glucose control in diabetes mellitus: a systematic review.
Coster, Gulliford, Seed, Powrie, & Swaminathan (2000) · Health Technology Assessment · doi:10.3310/hta4120 · Cited by 245
ROC analysis of noninvasive tests for peripheral arterial disease
Lijmer, J. G., Hunink, M. G. M., van den Dungen, J. J. A. M., Loonstra, J., & Smit, A. J. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(96)00036-1 · Cited by 241
SPECT brain imaging in epilepsy: a meta-analysis.
Devous, M. D., Thisted, R. A., Morgan, G. F., Leroy, R. F., & Rowe, C. C. (1998) · PubMed · Cited by 231
Kent, D. L., Haynor, D. R., Larson, E. B., & Deyo, R. A. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.158.5.1533084 · Cited by 219
Froelicher, V. F., Lehmann, K. G., Thomas, R., Goldman, S., Morrison, D., Edson, R., Lavori, P., Myers, J., Dennis, C., Shabetai, R., et al. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-128-12_part_1-199806150-00001 · Cited by 218
Assessment of radiologic tests: control of bias and other design considerations.
Begg, C. B., & McNeil, B. J. (1988) · Radiology · doi:10.1148/radiology.167.2.3357976 · Cited by 213
Does This Patient Have Deep Vein Thrombosis?
Anand, S. S. (1998) · JAMA · doi:10.1001/jama.279.14.1094 · Cited by 199
Systematic review of the diagnostic accuracy of dermatoscopy in detecting malignant melanoma
Mayer, J. (1997) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1997.tb138847.x · Cited by 196
A framework for clinical evaluation of diagnostic technologies.
Guyatt, G. H., Tugwell, P., Feeny, D. H., Haynes, R. B., & Drummond, M. (1986) · Europe PMC (PubMed Central) · Cited by 195
Morise, A. P., & Diamond, G. A. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90072-1 · Cited by 191
Moons, K. G. M., van Es, G.-A., Deckers, J. W., Habbema, J. D. F., & Grobbee, D. E. (1997) · Epidemiology · doi:10.1097/00001648-199701000-00002 · Cited by 189
Mol, B. W., Lijmer, J. G., Ankum, W. M., van der Veen, F., & Bossuyt, P. M. (1998) · Human Reproduction · doi:10.1093/humrep/13.11.3220 · Cited by 183
Self-citationCOMPARISON OF A SCREENING TEST AND A REFERENCE TEST IN EPIDEMIOLOGIC STUDIES
BUCK, A. A., & GART, J. J. (1966) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a120609 · Cited by 181
Methodologic problems of exercise testing for coronary artery disease: Groups, analysis and bias
Philbrick, J. T., Horwitz, R. I., & Feinstein, A. R. (1980) · The American Journal of Cardiology · doi:10.1016/0002-9149(80)90432-4 · Cited by 179
Interpretation of radiographs: effect of clinical history
Doubilet, P., & Herman, P. (1981) · American Journal of Roentgenology · doi:10.2214/ajr.137.5.1055 · Cited by 175
The accuracy of serum chlamydial antibodies in the diagnosis of tubal pathology: a meta-analysis
Mol, B. W. J., Dijkman, B., Wertheim, P., Lijmer, J., van der Veen, F., & Bossuyt, P. M. M. (1997) · Fertility and Sterility · doi:10.1016/s0015-0282(97)81435-5 · Cited by 174
Self-citationThe assessment of diagnostic tests. A survey of current medical research
Sheps, S. B. (1984) · JAMA · doi:10.1001/jama.252.17.2418 · Cited by 165
Vamvakas, E. C. (1998) · PubMed · Cited by 164
Diagnosis of arterial disease of the lower extremities with duplex ultrasonography
Koelemay, M. J. W., den Hartog, D., Prins, M. H., Kromhout, J. G., Legemate, D. A., & Jacobs, M. J. H. M. (1996) · Journal of British Surgery · doi:10.1002/bjs.1800830336 · Cited by 163
Detrano, R., Gianrossi, R., Mulvihill, D., Lehmann, K. G., Dubach, P., Colombo, A., & Froelicher, V. F. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90388-4 · Cited by 153
Systematic Reviews of Evaluations of Diagnostic and Screening Tests
Deeks, J. J. (2001) · Wiley eBooks · doi:10.1002/9780470693926.ch14 · Cited by 147
van den Hoogen, H. M. M., Koes, B. W., van Eijk, J. T. M., & Bouter, L. M. (1995) · Spine · doi:10.1097/00007632-199502000-00010 · Cited by 146
Ethnic and Sex Bias in Primary Care Screening Tests for Alcohol Use Disorders
Steinbauer, J. R., Cantor, S. B., Holzer, C. E., III, & Volk, R. J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-5-199809010-00002 · Cited by 134
Fallacies in the pathological confirmation of the diagnosis of Alzheimer's disease
Bowler, J. V., Muñoz, D. G., Merskey, H., & Hachinski, V. (1998) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp.64.1.18 · Cited by 133
How to read clinical journals: II. To learn about a diagnostic test.
(1981) · PubMed Central · Cited by 131
The Poor Quality of Early Evaluations of Magnetic Resonance Imaging
Cooper, L. S. (1988) · JAMA · doi:10.1001/jama.1988.03720220023019 · Cited by 128
Evaluating Bias and Variability in Diagnostic Test Reports
Mower, W. R. (1999) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(99)70422-1 · Cited by 123
Factors affecting sensitivity and specificity of a diagnostic test: the exercise thallium scintigram
Detrano, R., Jánosi, A., Lyons, K. P., Marcondes, G., Abbassi, N., & Froelicher, V. F. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90107-6 · Cited by 120
Does This Patient Have a Mole or a Melanoma?
Whited, J. D., & Grichnik, J. M. (1998) · JAMA · doi:10.1001/jama.279.9.696 · Cited by 120
ROC Curves For the Initial Assessment of New Diagnostic Tests
van der Schouw, Y. T., Verbeek, A. L. M., & RUIJS, J. (1992) · Family Practice · doi:10.1093/fampra/9.4.506 · Cited by 119
Shlipak, M. G., Lyons, W. L., Go, A. S., Chou, T. M., Evans, G. T., & Browner, W. S. (1999) · JAMA · doi:10.1001/jama.281.8.714 · Cited by 111
de Vries, S. O., Hunink, M. G. M., & Polak, J. F. (1996) · Academic Radiology · doi:10.1016/s1076-6332(96)80257-1 · Cited by 107
Lacasse, Y., Wong, E. Y. L., Guyatt, G. H., & Cook, D. (1999) · Thorax · doi:10.1136/thx.54.10.884 · Cited by 106
Bernardinis, M. D., Violi, V., Roncoroni, L., Boselli, A. S., Giunta, A., & Peracchia, A. (1999) · Critical Care Medicine · doi:10.1097/00003246-199910000-00035 · Cited by 105
Toward a Checklist for Reporting of Studies of Diagnostic Accuracy of Medical Tests
Bruns, D. E., Huth, E. J., Magid, E., & Young, D. S. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.7.893 · Cited by 103
Diagnostic accuracy of technetium-99m-MIBI myocardial SPECT in women and men.
Santana-Boado, C., Candell‐Riera, J., Castell‐Conesa, J., Aguadé‐Bruix, S., García-Burillo, A., Canela, T., González, J. M., Cortadellas, J., Ortega, D., & Soler‐Soler, J. (1998) · PubMed · Cited by 102
Method for evaluating research and guideline evidence
Liddle, J. (1997) · New South Wales Public Health Bulletin · doi:10.1071/nb97004 · Cited by 102
A review of near patient testing in primary care.
Hobbs, Delaney, Fitzmaurice, Wilson, Hyde, Thorpe, Earl-Slater, Jowett, S. M., & Tobias, . (1997) · Health Technology Assessment · doi:10.3310/hta1050 · Cited by 91
The Impact of Clinical History on Mammographic Interpretations
Elmore, J. G. (1997) · JAMA · doi:10.1001/jama.1997.03540250057032 · Cited by 89
How well can the chest radiograph diagnose left ventricular dysfunction?
Badgett, R. G., Mulrow, C. D., Otto, P. M., & Ramírez, G. (1996) · Journal of General Internal Medicine · doi:10.1007/bf02599031 · Cited by 86
Berry, Kelly, Hutton, Lindsay, Blaxill, Evans, Connelly, Tisch, Walker, Sivananthan, et al. (2000) · Health Technology Assessment · doi:10.3310/hta4350 · Cited by 82
Lensing, A. W. A., & Hirsh, J. (1993) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1651177 · Cited by 82
Cecil, M. P., Kosinski, A. S., Jones, M. T., Taylor, A. T., Alazraki, N. P., Pettigrew, R. I., & Weintraub, W. S. (1996) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(96)00014-5 · Cited by 82
Evidence-based evaluation of three imaging methods for the temporomandibular disc.
Liedberg, J., Panmekiate, S., Petersson, A. R., & Rohlin, M. (1996) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.25.5.9161176 · Cited by 80
Assessing quality of a diagnostic test evaluation
Mulrow, C. D., Linn, W. D., Gaul, M. K., & Pugh, J. A. (1989) · Journal of General Internal Medicine · doi:10.1007/bf02597398 · Cited by 77
The Architecture of Diagnostic Research
Haynes, R. B., & You, J. J. (2008) · doi:10.1002/9781444300574.ch2 · Cited by 77
Guidelines for the Assessment of New Diagnostic Tests
van der Schouw, Y. T., Verbeek, A. L. M., & Ruijs, S. H. J. (1995) · Investigative Radiology · doi:10.1097/00004424-199506000-00002 · Cited by 76
Diagnostic Efficiency of Home Pregnancy Test Kits: A Meta-analysis
Bastian, L. A. (1998) · Archives of Family Medicine · doi:10.1001/archfami.7.5.465 · Cited by 74
The Limited Spectrum of Patients Studied in Exercise Test Research
Philbrick, J. T. (1982) · JAMA · doi:10.1001/jama.248.19.2467 · Cited by 74
Estimating Diagnostic Test Accuracy Using a "Fuzzy Gold Standard"
Phelps, C. E., & Hutson, A. D. (1995) · Medical Decision Making · doi:10.1177/0272989x9501500108 · Cited by 73
Fecal screening tests in the approach to acute infectious diarrhea: a scientific overview
Huicho, L., Campos, M. A. L., Rivera, J., & Guerrant, R. L. (1996) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-199606000-00004 · Cited by 73
Body Mass Index Compared to Dual-Energy X-Ray Absorptiometry: Evidence for a Spectrum Bias
Curtin, F., Morabia, A., Pichard, C., & Slosman, D. O. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(97)00063-2 · Cited by 71
The identification of bias in studies of the diagnostic performance of imaging modalities.
Kelly, S., Berry, E., Roderick, P., Harris, K. M., Cullingworth, J., Gathercole, L., Hutton, J., & Smith, M. A. (1997) · British Journal of Radiology · doi:10.1259/bjr.70.838.9404207 · Cited by 71
Evaluating and comparing imaging techniques: a review and classification of study designs
Freedman, L. S. (1987) · British Journal of Radiology · doi:10.1259/0007-1285-60-719-1071 · Cited by 70
Bachmann, M. O., & Nelson, S. J. (1998) · Journal of Epidemiology & Community Health · doi:10.1136/jech.52.1.45 · Cited by 63
Screening for fragile X syndrome.
Murray, Cuckle, Taylor, & Hewison (1997) · Health Technology Assessment · doi:10.3310/hta1040 · Cited by 60
Cohen, M. B., Rodgers, R. P., Hales, M., Gonzales, J. M., Ljung, B., Beckstead, J. H., Bottles, K., & Miller, T. R. (1987) · PubMed · Cited by 59
Berbaum, K. S., Franken, E., & el-Khoury, G. Y. (1989) · American Journal of Roentgenology · doi:10.2214/ajr.153.6.1221 · Cited by 56
Does knowledge of the clinical history affect the accuracy of chest radiograph interpretation?
Good, B. C., Cooperstein, L. A., DeMarino, G. B., Miketic, L. M., Gennari, R. C., Rockette, H. E., & Gur, D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.154.4.2107662 · Cited by 55
Workup Bias in Prediction Research
Panzer, R. J., Suchman, A. L., & Griner, P. F. (1987) · Medical Decision Making · doi:10.1177/0272989x8700700209 · Cited by 55
Inter-observer and intra-observer variability of mammogram interpretation: a field study
Ciccone, G., Vineis, P., Frigerio, A., & Segnan, N. (1992) · European Journal of Cancer · doi:10.1016/0959-8049(92)90455-b · Cited by 54
Reference test errors bias the evaluation of diagnostic tests for ischemic heart disease
Boyko, E. J., Alderman, B. W., & Barón, A. E. (1988) · Journal of General Internal Medicine · doi:10.1007/bf02595925 · Cited by 54
Deeks, J. J. (1999) · Annals of Oncology · doi:10.1023/a:1008359805260 · Cited by 46
van Rijkom, H. M., & Verdonschot, E. H. (2009) · Caries Research · doi:10.1159/000262094 · Cited by 42
A Scale of Methodological Quality for Clinical Studies of Radiologic Examinations
Arrivé, L., Renard-Penna, R., Carrat, F., Belkacem, A., Dahan, H., Hir, P. L., Monnier‐Cholley, L., & Tubiana, J. M. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc0669 · Cited by 42
van der Schouw, Y. T. (1995) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(94)00144-f · Cited by 39
Bastian, L. A. (1997) · JAMA · doi:10.1001/jama.278.7.586 · Cited by 37
Context bias. A problem in diagnostic radiology
Egglin, T. K. (1996) · JAMA · doi:10.1001/jama.276.21.1752 · Cited by 36
Raab, S. S., Oweity, T., Hughes, J. H., et al. (2000) · American Journal of Clinical Pathology · doi:10.1309/4099-qald-nvgf-tm4g · Cited by 35
Studying a Study and Testing a Test: How to Read the Health Science Literature
Riegelman, R. K., & Hirsch, R. P. (1996) · Medical Entomology and Zoology · Cited by 33
O'Connor, P. W., Tansey, C. M., Detsky, A. S., Mushlin, A. I., & Kucharczyk, W. (1996) · Neurology · doi:10.1212/wnl.47.1.140 · Cited by 32
Modelling study quality in meta-analysis
Tritchler, D. (1999) · Statistics in Medicine · Cited by 31
Miller, T. D., Hodge, D. O., Christian, T. F., Milavetz, J. J., Bailey, K. R., & Gibbons, R. J. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)81373-9 · Cited by 28
Papers that report diagnostic or screening tests
(1998) · BMJ · doi:10.1136/bmj.316.7126.225 · Cited by 26
Estimating the sensitivity of cervical cytology: errors of interpretation and test limitations
Ronco, G., Montanari, G., Aimone, V., Parisio, F., Segnan, N., VALLE, A., & Volante, R. (1996) · Cytopathology · doi:10.1046/j.1365-2303.1996.39382393.x · Cited by 25
The spectrum of patients strongly influences the usefulness of diagnostic tests for pneumonia
Melbye, H., & Straume, B. (1993) · Scandinavian Journal of Primary Health Care · doi:10.3109/02813439308994838 · Cited by 24
Memorandum for the evaluation of diagnostic measures.
Köbberling, J. (1990) · PubMed · Cited by 24
SCREENING FOR ALCOHOL PROBLEMS IN PRIMARY CARE
Isaacson, J. H., & Schorling, J. B. (1999) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70179-6 · Cited by 22
How to read a paper: Papers that report diagnostic or screening tests
(1997) · BMJ · doi:10.1136/bmj.315.7113.942 · Cited by 22
Methodologic Problems in Exercise Testing Research
Detrano, R. (1988) · Archives of Internal Medicine · doi:10.1001/archinte.148.6.1289 · Cited by 20
Plasencia, C. M., Alderman, B. W., Barón, A. E., Rolfs, R. T., & Boyko, E. J. (1992) · Medical Decision Making · doi:10.1177/0272989x9201200306 · Cited by 19
Cuarón, A., Acero, A., Cárdenas, M., et al. (1980) · PubMed · Cited by 18
Methodologic Standards for Diagnostic Test Research in Pulmonary Medicine
Heffner, J. E., Feinstein, D., & Barbieri, C. (1998) · CHEST Journal · doi:10.1378/chest.114.3.877 · Cited by 16
Arana, G. W., Zarzar, M. N., & Baker, E. H. (1990) · Biological Psychiatry · doi:10.1016/0006-3223(90)90460-j · Cited by 13
Diagnostic Research: theory and application
Moons, K. G. M. (1996) · RePub (Erasmus University Rotterdam) · Cited by 10
Taube, A., & Tholander, B. (1990) · Acta Oncologica · doi:10.3109/02841869009091785 · Cited by 9
Bonis, P. A. (1997) · Hepatology · doi:10.1053/jhep.1997.v26.pm0009328332 · Cited by 8
Nierenberg, A. A. (1988) · JAMA · doi:10.1001/jama.1988.03720110061036 · Cited by 6
Harrell, F., Jr. (1996) · doi:10.1002/(sici)1097-0258(19960229)15:4<361::aid-sim168>3.0.co;2-4
Cited by
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Self-citationOlsson, B., Lautner, R., Andreasson, U., Öhrfelt, A., Portelius, E., Bjerke, M., Hölttä, M., Rosén, C., Olsson, C., Strobel, G., et al. (2016) · The Lancet Neurology · doi:10.1016/s1474-4422(16)00070-3 · Cited by 2,049
Zeng, X., Zhang, Y., Kwong, J. S. W., Zhang, C., Li, S., Sun, F., Niu, Y., & Du, L. (2015) · Journal of Evidence-Based Medicine · doi:10.1111/jebm.12141 · Cited by 2,082
Ma, L.-L., Wang, Y.-Y., Yang, Z.-H., Huang, D., Weng, H., & Zeng, X.-T. (2020) · Military Medical Research · doi:10.1186/s40779-020-00238-8 · Cited by 1,648
Gilbody, S., Richards, D., Brealey, S., & Hewitt, C. (2007) · Journal of General Internal Medicine · doi:10.1007/s11606-007-0333-y · Cited by 1,290
Metadata
- Authors
- Whiting, P., Rutjes, A., Dinnes, J., Reitsma, J., Bossuyt, P., & Kleijnen, J.
- Venue
- Health Technology Assessment
- Published
- 2004-06
- Volume
- 8
- Issue
- 25
- Pages
- iii, 1-234
- ISSN
- 1366-5278 (ISSN-L)
- 2046-4924
- OpenAlex
- W2004084637
- Cited by
- 372
- References
- 125
- FWCI
- 24.03
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.