CoChat

Pulse Transit Time and Blood Pressure During Cardiopulmonary Exercise Tests

Open access
WIBMER, T., DOERING, K., KROPF-SANCHEN, C., RÜDIGER, S., BLANTA, I., STOIBER, K. M., ROTTBAUER, W., SCHUMANN, C. · 2014 · Physiological Research
Cited by 79

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Pulse transit time (PTT), the interval between ventricular electrical activity and peripheral pulse wave, is assumed to be a surrogate marker for blood pressure (BP) changes. The objective of this study was to analyze PTT and its relation to BP during cardiopulmonary exercise tests (CPET). In 20 patients (mean age 51±18.4 years), ECG and finger-photoplethysmography were continuously recorded during routine CPETs. PTT was calculated for each R-wave in the ECG and the steepest slope of the corresponding upstroke in the plethysmogram. For each subject, linear and non-linear regression models were used to assess the relation between PTT and upper-arm oscillometric BP in 9 predefined measuring points including measurements at rest, during exercise and during recovery. Mean systolic BP (sBP) and PTT at rest were 128 mm Hg and 366 ms respectively, 197 mm Hg and 289 ms under maximum exercise, and 128 mm Hg and 371 ms during recovery. Linear regression showed a significant, strong negative correlation between PTT and sBP. The correlation between PTT and diastolic BP was rather weak. Bland-Altman plots of sBP values estimated by the regression functions revealed slightly better limits of agreements for the non-linear model (–10.9 to 10.9 mm Hg) than for the linear model (−13.2 to 13.1 mm Hg). These results indicate that PTT is a good potential surrogate measure for sBP during exercise and could easily be implemented in CPET as an additional parameter of cardiovascular reactivity. A non-linear approach might be more effective in estimating BP than linear regression.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.33549/physiolres.932581

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 79

Metadata

Authors
WIBMER, T., DOERING, K., KROPF-SANCHEN, C., RÜDIGER, S., BLANTA, I., STOIBER, K. M., ROTTBAUER, W., & SCHUMANN, C.
Venue
Physiological Research
Published
2014-06-16
Volume
63
Issue
3
Pages
287-296
ISSN
  • 0862-8408 (ISSN-L)
  • 1802-9973
OpenAlex
W2183841542
Cited by
79
References
4
FWCI
3.31
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.