Vertical Display Oscillation Effects on Forward Vection and Simulator Sickness
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The current study investigated the effects that vertical display oscillation had on the development of both vection and simulator sickness. METHODS: There were 16 subjects who were exposed to optic flow displays which simulated either: 1) constant velocity forward self-motion (pure radial flow); or 2) combined constant velocity forward and vertically oscillating self-motion (radial flow with vertical oscillation at one of three frequencies: 1.8, 3.7, or 7.4 Hz). During each 10-min display exposure, subjects rated the strength of their vection and eight symptoms listed on the Subjective Symptoms of Motion Sickness (SSMS) scale at 2-min intervals. Subjects also completed the Simulator Sickness Questionnaire (SSQ) designed by Kennedy and colleagues before and after each trial, which generated a total SSQ score and three SSQ subscores (nausea, oculomotor symptoms, and disorientation). RESULTS: Vertically oscillating displays (mean = 5.51; SD = 2.5) were found to produce significantly stronger vection ratings than non-oscillating displays (mean = 3.56; SD = 2.1). Vertically oscillating displays (mean = 58.18; SD = 32.2) were also found to produce significantly more severe sickness (as rated by total SSQ scores) than non-oscillating displays (mean = 29.67; SD = 24.7). Both vection and sickness symptoms increased in magnitude with prolonged exposure to optic flow. CONCLUSIONS: Our findings appear to represent a special case in visual self-motion perception where high-frequency vertical oscillation both enhances vection and increases simulator sickness when it is incorporated into an optic flow display simulating constant velocity self-motion in depth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulator Sickness Questionnaire: An Enhanced Method for Quantifying Simulator Sickness
Kennedy, R. S., Lane, N. E., Berbaum, K. S., & Lilienthal, M. G. (1993) · The International Journal of Aviation Psychology · doi:10.1207/s15327108ijap0303_3 · Cited by 5,457
Motion Sickness Adaptation: A Neural Mismatch Model
Reason, J. T. (1978) · Journal of the Royal Society of Medicine · doi:10.1177/014107687807101109 · Cited by 932 · cited 1×
“While definitions of sensory conflict differ (3,22,25), most theories would predict that pure radial flow displays should produce less sensory conflict than vertically oscillating radial flow displays.”
BackgroundBerthoz, A., Pavard, B., & Young, L. R. (1975) · Experimental Brain Research · doi:10.1007/bf00234916 · Cited by 456 · cited 4×
“(2) The SSMS scale consists of eight specific symptom questions that are summed to provide an overall measure of simulator sickness (5).”
BackgroundResultInfluentialMotion sickness: only one provocative conflict?
Bles, W., Bos, J. E., de Graaf, B., Groen, E., & Wertheim, A. H. (1998) · Brain Research Bulletin · doi:10.1016/s0361-9230(98)00115-4 · Cited by 335 · cited 8×
“009], and the disorientation sub-scores [F(3,42) = 5.”
BackgroundInfluentialVection and Simulator Sickness
Hettinger, L. J., Berbaum, K. S., Kennedy, R. S., Dunlap, W. P., & Nolan, M. D. (1990) · Military Psychology · doi:10.1207/s15327876mp0203_4 · Cited by 267
Lee, G. C. H., Yoo, Y., & Jones, S. (1997) · Computers & Industrial Engineering · doi:10.1016/s0360-8352(97)00186-1 · Cited by 27 · cited 2×
“Another study by Lee, Yoo and Jones (15) examined the relationship between vection and simulator sickness in a driving simulator.”
Background
Cited by
Virtual Reality Sickness: A Review of Causes and Measurements
Chang, E., Kim, H. T., & Yoo, B. (2020) · International Journal of Human–Computer Interaction · doi:10.1080/10447318.2020.1778351 · Cited by 969
Vection and visually induced motion sickness: how are they related?
Keshavarz, B., Riecke, B. E., Hettinger, L. J., & Campos, J. L. (2015) · Frontiers in Psychology · doi:10.3389/fpsyg.2015.00472 · Cited by 342
“Moderate and high positive correlations were also reported by Palmisano et al. (2007), who added viewpoint jitter to a constantly expanding flow field, which both increased the level of vection and increased ratings of VIMS.”
BackgroundCombined Pitch and Roll and Cybersickness in a Virtual Environment
Bonato, F., Bubka, A., & Palmisano, S. (2009) · Aviation, Space, and Environmental Medicine · doi:10.3357/asem.2394.2009 · Cited by 110
Self-citationA study of cybersickness and sensory conflict theory using a motion-coupled virtual reality system
Ng, A. K. T., Chan, L. K. Y., & Lau, H. Y. K. (2020) · Displays · doi:10.1016/j.displa.2019.08.004 · Cited by 116
Metadata
- Authors
- Palmisano, S., Bonato, F., Bubka, A., & Folder, J.
- Venue
- Aviation, Space, and Environmental Medicine
- Publisher
- Aerospace Medical Association
- Published
- 2007-10-01
- Volume
- 78
- Issue
- 10
- Pages
- 951-956
- ISSN
- 0001-9402 (ISSN-L)
- 0095-6562
- OpenAlex
- W2001345575
- Cited by
- 63
- References
- 6
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.