Determination of Corneal Biomechanical Behavior in-vivo for Healthy Eyes Using CorVis ST Tonometry: Stress-Strain Index
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Purpose: This study aims to introduce and clinically validate a new algorithm that can determine the biomechanical properties of the human cornea in vivo. Methods: A parametric study was conducted involving representative finite element models of human ocular globes with wide ranges of geometries and material biomechanical behaviour. The models were subjected to different levels of intraocular pressure (IOP) and the action of external air puff produced by a non-contact tonometer. Predictions of dynamic corneal response under air pressure were analysed to develop an algorithm that can predict the cornea’s material behaviour. The algorithm was assessed using clinical data obtained from 480 healthy participants where its predictions of material behaviour were tested against variations in central corneal thickness (CCT), IOP and age, and compared against those obtained in earlier studies on ex-vivo human ocular tissue. Results: The algorithm produced a material stiffness parameter (Stress-Strain Index or SSI) that showed no significant correlation with both CCT (p> 0.05) and IOP (p> 0.05), but was significantly correlated with age (p< 0.01). The stiffness estimates and their variation with age were also significantly correlated (p< 0.01) with stiffness estimates obtained earlier in studies on ex-vivo human tissue. Conclusions: The study introduced and validated a new method for estimating the in vivo biomechanical behavior of healthy corneal tissue. The method can aid optimization of procedures that interfere mechanically with the cornea such as refractive surgeries and introduction of corneal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
Determining in vivo biomechanical properties of the cornea with an ocular response analyzer
Luce, D. A. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.10.044 · Cited by 1,311 · cited 2×
“These included the Corneal Hysteresis (CH) and Corneal Resistance Factor (CRF) produced by the Ocular Response Analyzer (ORA) (Luce, 2005), and the Stiffness Parameter (SP) (Roberts et al., 2017) by the CorVis.”
MethodLiu, J., & Roberts, C. J. (2005) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2004.09.031 · Cited by 753 · cited 2×
“This challenge has made it difficult to produce accurate IOP estimates, that are free of the effects of corneal biomechanics (Liu and Roberts, 2005), and the same challenge exists in determining the tissue’s biomechanics that are free of the effects of IOP.”
BackgroundMethodSelf-citationDetection of Keratoconus With a New Biomechanical Index
Vinciguerra, R., Ambrósio, R., Elsheikh, A., Roberts, C. J., Lopes, B., Morenghi, E., Azzolini, C., & Vinciguerra, P. (2016) · Journal of Refractive Surgery · doi:10.3928/1081597x-20160629-01 · Cited by 502 · cited 2×
“With successful validation, SSI could help in identifying eyes with keratoconus, possibly increasing the sensitivity and specificity of indexes such as the Corvis Combined Biomechanical Index (CBI) (Vinciguerra et al., 2016) or the Tomography and Biomechanical Index (TBI) (Ambrósio et al., 2017b).”
MethodSelf-citationAmbrósio, R., Lopes, B. T., Faria-Correia, F., Salomão, M. Q., Bühren, J., Roberts, C. J., Elsheikh, A., Vinciguerra, R., & Vinciguerra, P. (2017) · Journal of Refractive Surgery · doi:10.3928/1081597x-20170426-02 · Cited by 477
Self-citationAmbrósio, R., Alonso, R. S., Luz, A., & Coca Velarde, L. G. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.06.025 · Cited by 451 · cited 2×
“The peripheral corneal thickness (PCT) was assumed larger than CCT by 150 microns (Avitabile et al., 1997; Ambrósio et al., 2006) with a linear growth in thickness between the two, and in the sclera, the thickness varied linearly from PCT at the limbus, to 80% of PCT at the equator and 120% of PCT…”
BackgroundResultAssessment of Corneal Biomechanical Properties and Their Variation with Age
Elsheikh, A., Wang, D., Brown, M., Rama, P., Campanelli, M., & Pye, D. (2007) · Current Eye Research · doi:10.1080/02713680601077145 · Cited by 394
Self-citationPepose, J. S., Feigenbaum, S. K., Qazi, M. A., Sanderson, J. P., & Roberts, C. J. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2006.09.036 · Cited by 369 · cited 1×
“…pressure (IOP) for effective glaucoma management (Kaushik et al., 2012; Elsheikh et al., 2015), refractive surgery planning (Roberts, 2002; Pepose et al., 2007), keratoconus risk profiling (Ortiz et al., 2007; Ambrósio et al., 2017a), optimization or judging different protocols of…”
BackgroundSelf-citationOcular Biomechanics and Biotransport
Ethier, C. R., Johnson, M., & Ruberti, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140055 · Cited by 288
Scarcelli, G., Kling, S., Quijano, E., Pineda, R., Marcos, S. C., & Yun, S. H. (2013) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-11387 · Cited by 285 · cited 1×
“Another attempt is the elastic modulus provided by Brillouin microscopy (Scarcelli et al., 2013), which, while related to the cornea’s material stiffness, is not compatible with the nonlinear stress-strain behavior that means the tissue does not have a unique modulus, but has a tangent modulus,…”
BackgroundScleral Biomechanics in the Aging Monkey Eye
Girard, M. J. A., Suh, J.-K. F., Bottlang, M., Burgoyne, C. F., & Downs, J. C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3363 · Cited by 208 · cited 1×
“…Data and Validation As another form of validation, the correlation between SSI and age that has been established in the two clinical datasets was compared to what had been found in an earlier study involving inflation tests on ex-vivo human corneas (Girard et al., 2009; Elsheikh et al., 2010b).”
ResultCharacterization of age-related variation in corneal biomechanical properties
Elsheikh, A., Geraghty, B., Rama, P., Campanelli, M., & Meek, K. M. (2010) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0108 · Cited by 204
Self-citationBiomechanics of the Cornea and Wavefront-guided Laser Refractive Surgery
Roberts, C. (2002) · Journal of Refractive Surgery · doi:10.3928/1081-597x-20020901-18 · Cited by 171 · cited 2×
“, 2015), 62 refractive surgery planning (Roberts, 2002;Pepose et al., 2007), keratoconus risk profiling 63 (Ortiz et al.”
BackgroundSelf-citationRegional variation in the biomechanical properties of the human sclera
Elsheikh, A., Geraghty, B., Alhasso, D., Knappett, J. A., Campanelli, M., & Rama, P. (2010) · Experimental Eye Research · doi:10.1016/j.exer.2010.02.010 · Cited by 168
Self-citationKaushik, S., Pandav, S. S., Banger, A., Aggarwal, K., & Gupta, A. (2012) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2011.10.032 · Cited by 153 · cited 2×
“This challenge has made it difficult to produce accurate IOP estimates, that are free of the effects of corneal biomechanics (Liu and Roberts, 2005), and the same challenge exists in determining the tissue’s biomechanics that are free of the effects of IOP.”
BackgroundMethodAge-related variations in the biomechanical properties of human sclera
Geraghty, B., Jones, S., Rama, P., Akhtar, R., & Elsheikh, A. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.10.011 · Cited by 146
Self-citationWhitford, C., Studer, H., Boote, C., Meek, K. M., & Elsheikh, A. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.11.006 · Cited by 94 · cited 1×
“Finite element models of full eye globes were developed by a bespoke ocular mesh-generator software tool [developed in house (Whitford et al., 2015)] and analyzed using Abaqus 6.14 FE solver (Dassault Systèmes Simulia Corp., Providence, RI, USA), Figure 1.”
MethodInfluentialSelf-citation3D simulation of the aqueous flow in the human eye
Villamarin, A., Roy, S., Hasballa, R., Vardoulis, O., Reymond, P., & Stergiopulos, N. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.02.007 · Cited by 85 · cited 1×
“The models had a fluid cavity filled with an incompressible fluid with a density of 1,000 kg/m3 to simulate the aqueous and vitreous and their incompressible behavior (Villamarin et al., 2012).”
MethodAvitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · Cornea · doi:10.1097/00003226-199711000-00007 · Cited by 74 · cited 1×
“These parameters were correlated with the diagnosis of keratoconus and showed significant increases after collagen cross-linking (CXL) (Bak-Nielsen et al., 2014) but could not provide measures of material behavior that were separate from the effects of geometry and IOP.”
BackgroundElastic properties of porcine ocular posterior soft tissues
Chen, K., Rowley, A. P., & Weiland, J. D. (2009) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.32571 · Cited by 72 · cited 1×
“Earlier studies also confirmed the much lower stiffness of the retina relative to the ocular outer tunic (cornea and sclera) (Chen et al., 2010) and for this reason, it was not included in the numerical models.”
ResultSelf-citationStress free configuration of the human eye
Elsheikh, A., Whitford, C., Hamarashid, R., Kassem, W., Joda, A., & Büchler, P. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.09.006 · Cited by 64
Self-citationAvitabile, T., Marano, F., Uva, M. G., & REIBALDI, A. (1997) · PubMed · Cited by 62
Age-Related Variation in the Biomechanical and Structural Properties of the Corneo-Scleral Tunic
Geraghty, B., Whitford, C., Boote, C., Akhtar, R., & Elsheikh, A. (2014) · Engineering materials and processes · doi:10.1007/978-3-319-03970-1_9 · Cited by 15
Self-citation
Metadata
- Authors
- Eliasy, A., Chen, K.-J., Vinciguerra, R., Lopes, B. T., Abass, A., Vinciguerra, P., Ambrósio Jr., R., Roberts, C. J., & Elsheikh, A.
- Venue
- Frontiers in Bioengineering and Biotechnology
- Publisher
- Frontiers Media SA
- Published
- 2019-05-16
- Volume
- 7
- Pages
- 105-105
- ISSN
- 2296-4185 (ISSN-L)
- OpenAlex
- W2945794815
- Cited by
- 221
- References
- 23
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.